Enbrel (etanercept)
DeviceArm 1 = Enbrel 50 mg Prefilled Syringe twice weekly
NCT Number: NCT00482170
Primary objective of this study is to compare patient satisfaction with the prefilled syringe (PFS) and the auto-injector (AI), two different delivery devices for etanercept after 12 weeks of use, using a 10 point scale form totally dissatisfied to totally satisfied.Secondary evaluation focus on the identification of patient and device attributes associated with patient satisfaction.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 3
Bruges, Belgium
For the measures of patient's satisfaction with and perceptions of, their device, standard Likert scales are used. This allows the magnitude of individual's perceptions and satisfaction to be measured on a multipoint scale anchored at each end. In addition, the study will describe patient perceptions related to device attributes, which are of importance in describing overall patient perception. A range of potential device benefits (e.g. ease of use, convenience, injection site pain, injection anxiety, injection confidence) will be captured using a questionnaire. The study aims to characterize patient attributes that will indicate when one device may result in greater patient satisfaction than another. Patient attributes are composed of patient characteristics (e.g. age, sex, demographics, social and educational status psychological status, willingness to self-manage, injection experience) and Psoriasis characteristics (e.g. disease severity, disease duration, co morbidities, prior treatment, quality of life). The study will also take the opportunity to measure health outcome measures as there may be important differences in cost of training and patient support between the two devices.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Arm 1 = Enbrel 50 mg Prefilled Syringe twice weekly
Arm 2 = Enbrel 50 mg Autoinjector twice weekly
Time frame: Week 12
Participant satisfaction was assessed by asking the question, "How satisfied are you with your injection device?" using a 0-10 point scale, where 0= totally dissatisfied and 10= totally satisfied.
Time frame: Week 12
Participant satisfaction was assessed by asking the question, "How satisfied are you with your injection device?" using a 0-10 point scale, where 0= totally dissatisfied and 10= totally satisfied.
Time frame: Baseline, Week 4 and Week 12
Participant satisfaction was assessed by asking the question "Are you satisfied with your injection device? and using a dichotomous response: Yes or No.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the delivery mechanism. Age categories were defined based on quartiles (Q) of ages observed. Participants were divided into quarters: less than or equal to (=<) 36 years, greater than (>) 36 years to 45 years, > 45 years to 55 years, > 55 years.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the delivery mechanism. Gender categories were defined as male and female.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the delivery mechanism. Socio-educational status categories were defined as reading or (/) writing capacity, high school /baccalaureate level and university level.
Time frame: Week 12
Participant satisfaction scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher score = greater satisfaction with injection device. Psychological status was assessed using participant rated questionnaire with 2 subscales for anxiety (HAD-A) and depression (HAD-D). Total score: 0 to 21 for each subscale; higher score = greater severity of symptoms. Score categories were based on quartiles of HAD-A and HAD-D scores observed. Participants were divided into quarters: =< 4, > 4 to 7, > 7 to 10, > 10 for HAD-A and =< 3, > 3 to 5, > 5 to 8, > 8 for HAD-D.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. The 13-item short form of the PAM survey assessed participants' knowledge, skill, and confidence for self-management; calibrated scale score ranged from 0 to 100. Higher scores indicated more confidence in managing participants' condition and lifestyle. Score categories were defined based on quartiles of PAM scores observed. Participants were divided into quarters: =< 47.4, > 47.4 to 56.4, > 56.4 to 68.5, > 68.5.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the injection device. The categories were defined based on presence of any prior experience of self-injection. Participants were divided into categories: yes and no.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the injection device. Duration of psoriasis categories were defined based on quartiles of the duration of psoriasis observed. Participants were divided into quarters: =< 11 years, > 11 years to 19 years, > 19 years to 28 years, > 28 years.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. PGA of Psoriasis scale ranges from 0 (no psoriasis) to 5 (severe disease). 'Clear' and 'Almost clear' includes all participants who were scored as a 0 or 1. Score categories were defined based on quartiles of PGA scores observed. Participants were divided into: =< 3, > 3 to 4, > 4.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. PASI: combined assessment of lesion severity and area affected into single score; range: 0= no disease to 72= maximal disease. Score categories were defined based on quartiles of PASI score observed. Participants were divided into quartiles: =< 11.2, > 11.2 to 16.2, > 16.2 to 21.9, > 21.9.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. Participant's assessment of general health was measured on 100 millimeter (mm) line visual analog scale (VAS). 0 mm = extremely bad to 100 mm = very well. Score categories were defined based on quartiles of VAS score observed. Participants were divided into quarters: =< 48, > 48 to 67.25, > 67.25 to 84, > 84.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. Participant's global assessment of psoriasis was measured using a 100 mm VAS, with 0 = no activity and 100 = extremely active psoriasis. Score categories were defined based on quartiles of participant's global assessment of psoriasis scores observed. Participants were divided into quarters: =< 63, > 63 to 76, > 76 to 88, > 88.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. DLQI is the dermatology-specific quality of life measure used for psoriatic population. The 10-item questionnaire has a score range of 0 to 30 with higher scores indicating poor quality of life. Score categories were defined based on quartiles of DLQI scores observed. Participants were divided into quarters: =< 8, > 8 to 13, > 13 to 18, > 18.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction for the injection device. Co-morbidities categories were defined based on current usage of tobacco and alcoholic beverages. Participants were divided into categories, yes and no, for both current tobacco usage and current alcohol usage.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the injection device. The categories were defined based on presence of any prior experience of systemic treatment or topical medication for psoriasis. Participants were divided into categories: yes and no.
Time frame: Week 12
Participant satisfaction was scored on a 10-point ordinal scale: 0=totally dissatisfied to 10=totally satisfied. Higher scores indicated greater satisfaction with the injection device. The categories were defined based on presence of any prior experience of injection. Participants were divided into categories: yes and no.
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "How easy was it to perform an injection with this device?" scored on a 5-point Likert scale (0= very easy to 4= very difficult).
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "How easy was it to use the device?" scored on a 5-point Likert scale (0= very easy to 4= very difficult).
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "How easy was it to dispose of the device?" scored on a 5-point Likert scale (0= very easy to 4= very difficult).
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "How easy is it to know when the injection is completed?" scored on a 5-point Likert scale (0= very easy to 4= very difficult).
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "How easy is it to hold the device whilst injecting?" scored on a 5-point Likert scale (0= very easy to 4= very difficult)
Time frame: Baseline, Week 4 and Week 12
Ease of use of injection device was assessed by participant's response to question, "Did you feel any hand discomfort whilst using the device?" scored on a 5-point Likert scale (0= none to 4= extreme).
Time frame: Baseline, Week 4 and Week 12
Ease of Use of Injection Device was assessed by participant's response to question, "How long does it take to perform the injection, including any preparation and disposal?" where time spent was recorded in minutes and categorized into 5 categories, ranging from 'less than 5 minutes' to 'more than 30 minutes'.
Time frame: Baseline, Week 4 and Week 12
Convenience of injection device was assessed by participant's response to question, "How much do you think injecting etanercept will interfere with your ability to enjoy social or leisure activities?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Convenience of injection device was assessed by participant's response to question, "Do you think injecting etanercept will interfere with your usual daily activities?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Convenience of injection device was assessed by participant's response to question, "How much do you think injecting etanercept will interfere with travelling on holiday or business or visiting?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Confidence in injection device was assessed by participant's response to question, "How confident are you in your management of your injections?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Confidence in injection device was assessed by participant's response to question, "How confident are you that you inject the right amount of medicine every time?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Confidence in injection device was assessed by participant's response to question, "How confident are you that you can inject yourself properly with the device?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Confidence in injection device was assessed by participant's response to question, "Are you confident that you have good control over the injection process?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Confidence in injection device was assessed by participant's response to question, "How confident are you that you injected yourself successfully?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Fear of Device was assessed by participant's response to question, "How nervous do you feel about your injections?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Fear of Device was assessed by participant's response to question, "How nervous do you feel about inserting the needle into your skin?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Fear of Device was assessed by participant's response to question, "Do you dislike injecting yourself with this device?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Fear of Device was assessed by participant's response to question, "Are you emotionally distressed or anxious about your injections?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Device characteristics were assessed by participant's response to question, "How much do you like the look of the device?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Device characteristics were assessed by participant's response to question, "How much do you like the feel of the device?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Device characteristics were assessed by participant's response to question, "How much does the device look like something you would feel comfortable to use?" scored on a 5-point Likert scale (0= not at all to 4= very much).
Time frame: Baseline, Week 4 and Week 12
Side effects related to administration were assessed by participant's response to question, "Do you experience pain during or immediately after the injection?" scored on a 5-point Likert scale (0= none to 4= severe).
Time frame: Baseline, Week 4 and Week 12
SF-STAI is a 6 item short form. Global score = sum of coded answers/number of answered questions multiplied by 6, with answers coded on a 4 point Likert scale, where 1 = least anxious and 4 = most anxious. The global score ranges from 6 to 24, where higher score shows greater anxiety.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. The age was determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. Number of female and male participants was determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. Number of participants corresponding to each socio-educational level (reading or writing, high school or baccalaureate level, university level) was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied, less satisfied) using multiple correspondence analysis and an ascending hierarchical classification. Psychological status: assessed using participant rated questionnaire with 2 subscales for anxiety (HAD-A) and depression (HAD-D). Total score: 0 to 21 for each subscale; higher score = greater severity of symptoms. HAD score was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied, less satisfied) using multiple correspondence analysis and ascending hierarchical classification. The 13-item short form of PAM survey assessed participants' knowledge, skill, and confidence for self-management; score range 0 to 100. Higher scores indicated more confidence in managing participants' condition and lifestyle. PAM score was determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. Numbers of participants with and without prior injection experience were determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. Numbers of participants with and without prior self-injection experience were determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. The duration of psoriasis was determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. PGA of psoriasis scale ranges from 0 (no psoriasis) to 5 (severe disease). 'Clear' and 'Almost clear' includes all participants who were scored as a 0 or 1. The PGA score was determined for each cluster of participants.
Time frame: Baseline
Participant perception:assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using multiple correspondence analysis and ascending hierarchical classification. PASI: combined assessment of lesion severity and area affected into single score; range: 0=no disease to 72=maximal disease. While assessing, body was divided into 4 sections: head, upper extremities, trunk, lower extremities. PASI score was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using multiple correspondence analysis and ascending hierarchical classification. Participant's assessment of general health was measured on 100mm line visual analog scale (VAS). 0mm = extremely bad to 100mm = very well. The participant's assessment of general health score was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using multiple correspondence analysis and ascending hierarchical classification. Participant's global assessment of psoriasis was measured using a 100 mm VAS, with 0 = no activity and 100 = extremely active psoriasis. The participant's assessment of psoriasis score was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using multiple correspondence analysis and ascending hierarchical classification. DLQI is the dermatology-specific quality of life measure used for psoriatic population. The 10-item questionnaire has a score range of 0 to 30 with higher scores indicating poor quality of life. The DLQI score was determined for each cluster of participants.
Time frame: Baseline
Participant perception: assessed with 26 questions of device attribute and participant questionnaire. Based on scores assigned to 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using multiple correspondence analysis and ascending hierarchical classification. Co-morbidities included current usage of tobacco and alcoholic beverages. Numbers of participants with and without co-morbidities were determined for each cluster of participants.
Time frame: Baseline
Participant perception was assessed with the 26 questions of the device attribute and participant questionnaire. Based on the scores assigned to the 26 questions, participants were divided into 3 clusters (very satisfied, satisfied and less satisfied) using a multiple correspondence analysis and an ascending hierarchical classification. Numbers of participants with and without prior experience of systemic or topical treatment for psoriasis were determined for each cluster of participants.
Pfizer
Industry
A 3 Month, Randomised, Open Label, Parallel Group, Descriptive Study to Explore and Compare Perceptions and Satisfaction for Two Different Delivery Mechanisms for Etanercept (Etanercept Auto-injector and the Etanercept Prefilled Syringe) in Patients With Psoriasis.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01778569
Cardiovascular Disease, Cardiovascular Diseases
Bethesda, Maryland, United States
View Trial DetailsNCT05295979
Psoriasis, Skin Diseases
Hong Kong
View Trial DetailsNCT04728165
Psoriasis, Skin Diseases
Bethesda, Maryland, United States
View Trial DetailsNCT07712731
Psoriasis, Skin Diseases
Baotou, China
View Trial Details