university of Sciences and Technology
Sanaa, 009671, Yemen
NCT Number: NCT07162389
Early Stability of Short vs. Standard Dental Implants in the Posterior Mandible
This study compares how well short dental implants (7mm) work compared to standard-length implants (11mm) when placed in the back part of the lower jaw. Both types of implants have special shallow threads designed to reduce stress on the bone. The main goal is to see how stable they are during the first 4 weeks after placement-a critical time for healing.
* Short implants may be a good option for patients with limited jawbone height, avoiding the need for bone grafting. * Understanding their early stability helps dentists decide when it's safe to place teeth on them. * This study uses advanced tools like 3D scans (CBCT) and implant stability measurements (ISQ) to track healing.
What will happen in the study?
1. Screening: A dental exam and 3D scan to check bone quality. 2. Implant Placement:
* Short (7mm) or standard (11mm) implant, depending on your bone height. * Minimally invasive surgery with local anesthesia. 3. Follow-ups: Painless stability checks at end of 1, 2, 3, and 4 weeks using a small device (RFA).
Who can participate?
Adults (18-60 years) missing posterior teeth in the lower jaw, with:
* Enough bone width (≥6.5mm). * No uncontrolled health conditions (e.g., severe diabetes). * Non-smokers or light smokers (<10 cigarettes/day). * Benefits: Free implant placement and monitoring; contributes to better dental care. * Risks: Typical surgery risks (swelling, infection); rare nerve injury (<5% chance).
How long is the study?
* Active participation: 4 weeks (with optional long-term follow-up). * Total study duration: ~12 months (including data analysis). Mohammad Abdulwahab Al-Jonaid University of Science and Technology, Sana'a. * Supervisor: Dr. Ali Al-Hudaied, Oral and Maxillofacial Surgery Specialist.
This study is active but is not currently recruiting participants.
18 year–60 year
All sexes
Interventional
Not applicable
Sanaa, 009671, Yemen
A prospective, controlled, parallel-group pilot clinical trial comparing 7mm short implants (SHI) versus 11mm standard implants (SDI) with identical shallow-thread macrodesign (depth <0.5mm) and 4.2mm diameter. Implant allocation is anatomically driven based on CBCT-measured vertical bone height (7mm group: 8.5-9mm residual bone; 11mm group: ≥12.5mm).
Technical Innovations
Bone Density Integration
Quality Controls
Rationale for 4-Week Endpoint
Focuses on the critical early healing phase where:
Technical Constraints
Innovative Aspects
First clinical study to combine:
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A 7mm long, 4.2mm diameter dental implant with shallow thread (<0.5mm depth) Macrodesign, surgically placed in the jawbone to restore missing teeth
A 11mm long, 4.2mm diameter dental implant with shallow thread (<0.5mm depth) macrodesign, surgically placed in the jawbone to restore missing teeth.
Time frame: Measurement at implant placement(Day 0)
Mean Resonance frequency Analysis(RFA) measurement taken immediately post-implantation(T0), to assess primary mechanical stability. ISQ range 1-100, low stability <60, medium stability 60 to 69, high more than or equal 70. Reported as mean ISQ value per group.
Time frame: Measurement at during implant placement (intraoperative)
The rotational torque in Ncm,applied during the final quarter-turn of implant insertion. This is direct measure of primary mechanical stability. Reported as mean ITV per group.
Time frame: from implant placement (Day 0) through week4
The mean lowest point of stability curve , calculated as the greatest negative change in ISQ value from the baseline T0, measurement for each implant during the 4 -week monitoring period.
Time frame: from Day0 , through week 4.
The mean time in days post implantation at which the ISQ value begins to consistently increase, indicating the start biological secondary stability. Defined as the time point after the nadir -T2or T3.where the ISQ value shows a positive increase confirmed at the subsequent measurement.
University of Science and Technology, Yemen
Other
Early Stability of Short Dental Implants With Shallow Threads in the Posterior Mandible: A Controlled Clinical Pilot Study .
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07424742
Alveolar Bone Atrophy, Alveolar Bone Loss
Sanaa, Sanaa Governorate, Yemen
View Trial DetailsNCT07526129
Alveolar Bone Atrophy, Alveolar Bone Loss
Beirut, Lebanon
View Trial DetailsNCT07526337
Alveolar Bone Atrophy, Alveolar Bone Grafting
Beirut, Lebanon
View Trial DetailsNCT07002931
Alveolar Bone Atrophy, Alveolar Bone Loss
Cairo, Cairo Governorate, Egypt
View Trial Details