Osama Abdelaziz Abdelreheem
Cairo, Egypt
NCT Number: NCT07520227
Is patient specific customized computer assisted 3D PEEK plates more superior to 3D titanium plate in fixation of mandibular angle fractures?
Looking for future studies?
Notify Me18 year–60 year
All sexes
Interventional
Not applicable
Cairo, Egypt
Open Reduction Internal fixation (ORIF) of mandibular angle fractures using titanium plating systems had several drawbacks including sepsis with subsequent wound dehiscence and the need for 2nd surgery which is attributed to bone loss as a result of the elevated modulus of elasticity of titanium hardware. Accordingly, attempts were made to overcome problems encountered with the titanium plating system. In this study, custom made PEEK 3D plates will be used in ORIF of mandibular angle fractures. The main beneficial property of PEEK material is its lower modulus of elasticity that is close to that of living bone with subsequent elimination of the problem of stress shielding phenomenon encountered with titanium plating system. PEEK material has other advantages including biocompatibility, mechanical strength, durability, resistance to high degree of temperature without dimensional alteration.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Patient-specific PEEK plates manufactured using CAD/CAM technology and fixed using titanium screws.
Conventional 3D titanium plates used for fixation of mandibular angle fractures with titanium screws.
Time frame: 1 week, 1 month, and 6 months postoperatively
Occlusal stability was recorded as stable or unstable. Occlusal stability was assessed clinically by evaluating the intercuspation between maxillary and mandibular teeth. Proper occlusion was defined as normal intercuspation without premature contacts or occlusal discrepancies. Any deviation, including open bite or malocclusion, was recorded during follow-up.
Time frame: 1 week, 1 month, and 6 months postoperatively
Condylar seating was assessed radiographically using standardized panoramic radiographs. The position of the mandibular condyle within the glenoid fossa was evaluated. Proper condylar seating was defined as a normal anatomical position without displacement. Any deviation from the normal position was recorded as improper.
Time frame: 1 week, 1 month, and 6 months postoperatively
Postoperative infection was recorded as present or absent.
Time frame: 1 week, 1 month, and 6 months postoperatively
Wound dehiscence was recorded as present or absent.
Time frame: 1 week, 1 month, and 6 months postoperatively
Need for second surgery was recorded as yes or no.
Cairo University
Other
Comparative Evaluation of 3D-printed Polyetheretherketone (PEEK) Plates Versus Titanium 3D Plate for Fracture Fixation at the Mandibular Angle
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02283528
Craniocerebral Trauma, Facial Injuries
Atlanta, Georgia, United States
View Trial DetailsNCT07736430
Craniocerebral Trauma, Facial Injuries
Ismailia, Egypt
View Trial DetailsNCT07590401
Craniocerebral Trauma, Facial Injuries
Alexandria, Azarita, Egypt
View Trial DetailsNCT07221916
Craniocerebral Trauma, Facial Injuries
San Francisco, California, United States
View Trial Details