Université Libre de Bruxelles
Brussels, Brussels Capital, 1070, Belgium
NCT Number: NCT05508711
The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Brussels, Brussels Capital, 1070, Belgium
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Concomitant cardiac output measurement with transesophageal echocardiography and with the FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device in 3 different positions (horizontal supine, Trendelenburg and reverse Trendelenburg position).
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in horizontal supine position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in reverse Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Université Libre de Bruxelles
Other
Comparability of Transesophageal Echocardiography and Continuous Mini-invasive FloTrac/Vigileo System (© Edwards Lifesciences) for the Determination of Cardiac Output in Three Different Positions During General Anesthesia
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03172689
Cardiac Output
Nijmegen, Gelderland, Netherlands
View Trial DetailsNCT04941248
Cardiac Output
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT05648279
Anesthesia, Cardiac Output
Graz, Austria
View Trial DetailsNCT05428384
Cardiac Output, Cardiovascular Diseases
Augusta, Georgia, United States
View Trial Details