Skip to main content
OpenTrials
Enrolling by Invitation

NCT Number: NCT05560204

Combined Pulsed-field Ablation (PFA) and Left Atrial Appendage Occlusion Using Watchman Flx or Amulet

AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC. As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe.

Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx (Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx versus Amulet device.

In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx or the Amulet device.

Enrolling by Invitation

Interested in participating?

Request Info

Key information

Age range

19 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Prince of Wales Hospital

Hong Kong, Shatin, 0000

About this study

Atrial fibrillation (AF) is the most common cardiac arrythmia globally. Its prevalence ranges between 2-4% worldwide. It is associated with significant morbidity and mortality. AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC . As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe. However, the current AF ablation techniques (radiofrequency ablation and cryoballoon ablation) requires a less posterior transseptal access while LAAO requires a posterior-inferior transseptal access. This could potentially make LAAO after same procedure AF ablation using the same transseptal access more challenging. Besides, current ablation techniques would induce edema over pulmonary ridge, which could potentially result in significant peri-device leak (PDL) post LAAO after edema subsided. Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx (Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx versus Amulet device. In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx or the Amulet device.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Paroxysmal or persistent non- valvular atrial fibrillation
  • CHADS2-VASc >=2
  • Age >=18; and able to give written consent

Exclusion criteria

  • are in permanent atrial fibrillation
  • are not eligible for 3 months of oral anticoagulant post ablation
  • has left Atrial thrombus identified by pre-procedure TEE or during procedure
  • had received prior left atrial appendage closure procedure (percutaneous or surgical)
  • are planned to receive concomitant ablation procedure or structural heart interventions other than AF ablation and LAAO (e.g SVT ablation, Aflutter ablation, PFO closure, leadless pacemaker, ASD Closure, etc)
  • patient whom refused or cannot tolerate procedural or post procedural follow-up TEE

Treatment and study plan

Combined Pulsed-field Ablation (PFA) + Left Atrial Appendage Occlusion (LAAO)

Device

Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation

Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC

Primary outcomes

  1. Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE

    Time frame: 45-90 days

    Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE

Secondary outcomes

  1. LAAO technical success rate

    Time frame: Baseline

    successful device implantation without device related complication and peri-device leak >5mm

  2. Rate of procedural related complications

    Time frame: baseline, 45-90 days, 6-months, 12-months

    stroke, pericardial effusion, device embolization, mortality

  3. Total ablation time

    Time frame: baseline, 45-90 days, 6-months, 12-months

    Total ablation time

  4. LAAO procedural time

    Time frame: baseline, 45-90 days, 6-months, 12-months

    LAAO procedural time

  5. Need of additional transseptal puncture for LAAO

    Time frame: baseline, 45-90 days, 6-months, 12-months

    Need of additional transseptal puncture for LAAO

  6. Number of device recapture (full or partial)

    Time frame: baseline, 45-90 days, 6-months, 12-months

    Number of device recapture (full or partial)

  7. Number of device used

    Time frame: baseline, 45-90 days, 6-months, 12-months

    Number of device used

  8. PFA acute technical success

    Time frame: baseline, 45-90 days, 6-months, 12-months

    electric isolation of 4 pulmonary veins) by pre-ablation and post ablation mapping

  9. AF ablation procedural success

    Time frame: baseline, 45-90 days, 6-months, 12-months

    AF ablation procedural success, defined as no ECG, holter, or rhythm strip documentation of recurrence of AF, AT, Aflutter lasting more than 30 seconds at 1 year

  10. Number of Participants with 1-year clinical events

    Time frame: baseline, 45-90 days, 6-months, 12-months

    bleeding or thromboembolic event

Sponsors and collaborators

Lead sponsor

Prince of Wales Hospital, Shatin, Hong Kong

Other

Registry information

Official study title

Combined Pulsed-field Ablation (PFA) and Left Atrial Appendage Occlusion Using Watchman Flx or Amulet: A Randomized Controlled Study

Acronym: COMPAWA

Important dates

Study start
2023
Primary completion
2026
Study completion
2027
First posted
Sep 29, 2022
Registry last updated
Nov 29, 2024

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.