Skip to main content
OpenTrials
Completed

NCT Number: NCT04977908

Closing the Loop in Adults With Type 1 Diabetes (CLEAR)

The main objective of this study is to determine whether home use of fully closed-loop glucose control applying ultra-rapid Lispro insulin is superior to standard insulin pump therapy with continuous glucose monitoring (CGM) in adults with type 1 diabetes on insulin pump therapy with sub-optimal glycaemic control (HbA1c ≥ 8.0%).

This is an open-label, single centre, randomised, crossover design study, involving a run-in period followed by two study periods during which glucose levels will be controlled either by an automated closed-loop system using ultra-rapid Lispro insulin or by participants usual insulin pump therapy with continuous glucose monitoring in random order. A total of up to 30 adults (aiming for 24 completed participants) with T1D on insulin pump therapy will be recruited through diabetes clinics and other established methods. Participants who drop out of the study within the first 4 weeks of the first intervention arm will be replaced.

Participants will receive appropriate training in the safe use of the closed-loop devices. Participants will have access to the study team during the home study phase with 24/7 telephone support.

The primary outcome is time spent in target range between 3.9 and 10.0 mmol/L as recorded by CGM over the 8 week period. Secondary outcomes are HbA1c, time spent with glucose levels above and below target as recorded by CGM, and other CGM-based metrics in addition to insulin requirements. Safety evaluation comprises severe hypoglycaemic episodes, diabetic ketoacidosis (DKA) events and other adverse and serious adverse events.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Cambridge University Hospitals NHS Foundation Trust

Cambridge, CB2 0QQ, United Kingdom

About this study

Purpose of the clinical trial:

To determine whether home use of fully closed-loop applying ultra-rapid Lispro insulin is superior to insulin pump therapy with continuous glucose monitoring (CGM).

Study objective:

The study objective is to compare home use of fully closed-loop glucose control applying ultra-rapid Lispro insulin with standard insulin pump therapy with CGM.

  • EFFICACY: The objective is to assess the efficacy of fully closed-loop glucose control applying ultra-rapid Lispro insulin in maintaining CGM glucose levels within the target range from 3.9 to 10.0 mmol/l, as compared to standard insulin pump therapy combined with CGM.
  • SAFETY: The objective is to evaluate the safety of fully closed-loop glucose control in terms of episodes of severe hypoglycaemia, hyperglycaemia and other adverse events and adverse device effects.
  • UTILITY: The objective is to determine the percentage of time when closed-loop was operational, and usability and acceptance of the closed-loop system.

Participating clinical centres:

Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge

Sample Size:

24 adults completing the study. Up to 30 participants will be recruited to allow for dropouts.

Maximum duration of study for a participant:

20 weeks (5 months)

Recruitment The participants will be recruited through the adult diabetes outpatient clinics or other established methods.

Consent:

Participants will be asked to provide written informed consent.

Baseline Assessment:

Eligible participants will undergo a baseline evaluation including a blood sample for the measurement of HbA1c, renal, liver functions, full blood count, thyroid functions and coeliac antibody screen (if not done in the previous 3 months). Urine pregnancy test will be done in females of child bearing age. Human factor questionnaires will be administered.

Run-in Period During the 2-3 week run-in period, participants will use their own insulin pump and wear a masked CGM system. At the end of the run-in period, for compliance, at least 10 days of CGM data need to be recorded. CGM data during the run-in period will be used to assess baseline glucose control before the start of the first home study phase.

Randomisation:

Eligible participants will be randomised using randomisation software to the use of closed-loop glucose control or to standard pump therapy with CGM. There will be no washout period between the two intervention periods.

Automated closed-loop:

Training on the use of closed-loop will be provided by the research team during a 2 to 3 hour session in an outpatient setting (clinical research facility) or may be done remotely. Competency on the use of study insulin pump, study CGM and closed-loop system will be evaluated using a competency assessment tool developed by the research team. Further training may be delivered as required. Participants will be advised to use the closed-loop system with ultra-rapid Lispro insulin for next 8 weeks.

Conventional insulin pump therapy with CGM:

Participants will use their own insulin pump and study CGM. Training on the use of real-time CGM and how to interpret real-time will be provided. Participants will use standard insulin pump therapy, with their usual insulin, and real-time CGM for the next 8 weeks.

Cross-over Assessment:

At the end of the first intervention period, a blood sample for the measurement of HbA1c will be taken and human factor questionnaires will be administered.

End of study assessments:

A blood sample will be taken for measurement of HbA1c and human factor questionnaires will be administered. Study devices will be returned and participants will resume usual care.

Procedures for safety monitoring during trial:

Standard operating procedures for monitoring and reporting of all adverse events and adverse device events will be in place, including serious adverse events (SAE), serious adverse device effects (SADE) and specific adverse events (AE) such as severe hypoglycaemia.

A data monitoring and ethics committee (DMEC) will be informed of all serious adverse events and any unanticipated adverse device/method effects that occur during the study and will review compiled adverse event data at periodic intervals.

Criteria for withdrawal of patients on safety grounds:

A participant may terminate participation in the study at any time without necessarily giving a reason and without any personal disadvantage. An investigator can stop the participation of a subject after consideration of the benefit/risk ratio. Possible reasons are:

  • Serious adverse events
  • Significant protocol violation or non-compliance
  • Failure to satisfy competency assessment
  • Decision by the investigator, or the sponsor, that termination is in the participant's best medical interest
  • Pregnancy, planned pregnancy, or breast feeding
  • Allergic reaction to insulin
  • Technical grounds (e.g. participant relocates)

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The participant has type 1 diabetes as defined by WHO for at least 1 year
  • The participant is 18 years of age or older
  • The participant will have been on an insulin pump for at least 6 months with good knowledge of insulin self-adjustment
  • The participant is treated with one of the rapid acting or ultra-rapid acting insulin analogues (Insulin Aspart, faster acting insulin Aspart, Insulin Lispro, ultra-rapid Lispro insulin or Insulin Glulisine)
  • HbA1c ≥8.0% (64 mmol/mol) based on analysis from local laboratory
  • The participant is willing to wear closed-loop devices
  • The participant is willing to follow study specific instructions
  • Female participants of child bearing age should using effective contraception and must have a negative urine-HCG pregnancy test at screening.

Exclusion criteria

  • Any physical or psychological disease or condition likely to interfere with the normal conduct of the study and interpretation of the study results
  • Known or suspected allergy against insulin
  • Total daily insulin dose > 2 IU/kg/day
  • Use of a closed-loop system within the past 30 days
  • Participant is pregnant or breast feeding or planning pregnancy within next 12 months
  • Severe visual impairment
  • Severe hearing impairment
  • Lack of reliable telephone facility for contact
  • Participant not proficient in English

Treatment and study plan

CamAPS HX

Device

Fully automated closed-loop system (CamAPS HX) with ultra-rapid Lispro insulin

Standard insulin pump therapy with CGM

Device

Participants usual insulin pump therapy with Dexcom G6 CGM

Primary outcomes

  1. Time in target glucose range

    Time frame: 8-week home use

    Time spent in the target glucose range from 3.9 to 10.0 mmol/l (70 to 180mg/dl) based on continuous glucose monitoring (CGM)

Secondary outcomes

  1. Time spent above the target glucose range

    Time frame: 8-week home use

    Time spent above target glucose (10.0 mmol/l) (180 mg/dl) based on CGM

  2. Time spent below the target glucose range

    Time frame: 8-week home use

    Time spent below target glucose (3.9mmol/l) (70mg/dl) based on CGM

  3. Mean glucose

    Time frame: 8-week home use

    Average of sensor glucose levels

  4. Standard deviation and coefficient of variation of glucose

    Time frame: 8-week home use

    Standard deviation and coefficient of variation of CGM glucose levels

  5. Time spent in hypoglycaemia

    Time frame: 8-week home use

    Time with glucose levels < 3.0 mmol/l (54mg/dl) based on CGM

  6. Time spent in hyperglycaemia

    Time frame: 8-week home use

    Time with glucose levels >13.9 mmol/l (250mg/dl) and > 16.7 mmol/l) (300mg/dl)

  7. HbA1c

    Time frame: after 8-week home use

    Glycated haemoglobin measured at the end of the treatment period

  8. Total, basal, and bolus insulin dose

    Time frame: 8-week home use

    Total, basal, and bolus insulin dose

Other outcomes

  1. Safety evaluation

    Time frame: 8-week home use

    The number of episodes of hypoglycaemia, DKA and / or significant ketonemia (> 3.0mmol/l) as well as nature and severity of any other adverse events including SADEs and SAEs.

  2. Utility evaluation

    Time frame: 8-week home use

    Frequency and duration of use of the closed-loop system at home

  3. Human Factor assessment

    Time frame: 8-week home use

    Expectations, attitudes and responses to the closed-loop system will be assessed using questionnaires.

    INSPIRE questionnaire PAID questionnaire Hypoglycaemia Confidence Scale

Sponsors and collaborators

Lead sponsor

University of Cambridge

Other

Collaborators

  • Cambridge University Hospitals NHS Foundation Trust

Registry information

Official study title

An Open-label, Single-centre, Randomised, Two-period, Crossover Study to Assess the Efficacy, Safety and Utility of Closed-loop Glucose Control Compared to Standard Insulin Pump Therapy Combined With Continuous Glucose Monitoring in Adults With Type 1 Diabetes (CLEAR Study)

Important dates

Study start
2021
Primary completion
2023
Study completion
2023
First posted
Jul 27, 2021
Registry last updated
Nov 21, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.