Closing the Loop 24/7 in Adolescents With Type 1 Diabetes

Type 1 diabetes (T1D) is one of the most common chronic childhood diseases requiring lifelong insulin therapy. Children and adolescents with T1D need regular insulin injections or the continuous insulin delivery using an insulin pump in order to keep blood glucose levels normal. We know that keeping blood sugars in the normal range will help prevent long-term diabetes-related complications involving the eyes, kidneys and heart. However, achieving treatment goals can be very difficult particularly due to the risk of low glucose levels (hypoglycaemia). One solution is to use a system where the amount of insulin injected closely matches the blood sugar levels on a continuous basis. This can be achieved by what is known as a "closed-loop system" where a small glucose sensor placed under the skin communicates with a computer containing an algorithm that drives a subcutaneous insulin pump. We have been testing such a system in Cambridge over the last five years in children and have found that this system is effective, and superior to usual insulin pump therapy, at maintaining tight glucose control. More recently the system has been tested overnight, in the home setting, for three weeks in adolescents during a pilot single-centre study.

The next step is to evaluate use of the closed loop system day and night over a period of 7 days (phase 1) and 21 days (phase 2) in adolescents with type 1 diabetes. In the present study we are planning to study 24 (12 phase 1 ans 12 phase 2) young people aged 10-18 years on insulin pump therapy. This study will involve two 7 (phase 1) and 21 (phase 2) day home study periods, during which glucose levels will be controlled either by an automated closed-loop system or by subjects usual insulin pump therapy combined with continuous glucose monitoring alone in random order. Prior to the closed-loop study period, there will be a training period in the clinical research facility, which will allow participants to familiarise themselves with the closed-loop system before going home.

We aim to to determine the effect of the closed-loop computer algorithm in keeping glucose levels between 3.9 and 10.0 mmol/L during the daytime and overnight.

Completed

Looking for future studies?

Notify Me

Key information

Age range

10 year–18 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

University of Cambridge

Cambridge, CB2 0QQ, United Kingdom

About this study

The main objective of this study is to determine the efficacy, safety and utility of automated closed-loop glucose control in the home setting over a short term period, including the daytime and during the activities of normal daily living. This study builds on previous and on-going studies of closed-loop systems that have been performed in Cambridge in children and adolescents with type 1 diabetes in the clinical research facility and in the home setting. The data and experienced gained from this study will be utilised in planning future home studies.

This is an open-label, single-centre, randomised, crossover study, involving two, 7 day (phase 1) and 21 day (phase 2) home study periods during which glucose levels will be controlled either by an automated closed-loop system or by subjects' usual insulin pump therapy combined with continuous glucose monitoring in random order. A total of up to 30 children and adolescents aged 10 to 18 years with T1D on insulin pump therapy will be recruited through diabetes clinics, to allow for 12 completed subjects available for assessment in each study phase.

Subjects will receive appropriate training by the research team on the safe use of the closed-loop insulin delivery system. During the training visit in a clinical research centre, subjects will be encouraged to mimic their usual daily activities and will be allowed to walk inside hospital premises. Subjects will be advised to discontinue automated closed-loop insulin delivery and follow their usual insulin pump therapy for certain activities such as periods of strenuous exercise during the 7 day (phase 1) and 21 day (phase 2) home study phase.

The primary outcome is time spent in target range between 3.9 and 10.0 mmol/L as recorded by CGM (conservatively adjusted for potential over-estimation). Secondary outcomes are the time spent with glucose levels above and below target, as recorded by CGM, and other CGM-based metrics. Safety evaluation comprises the tabulation of severe hypoglycaemic episodes.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • The subject is between 10 and 18 years of age (inclusive)
  • The subject has type 1 diabetes, as defined by WHO for at least 1 year or is confirmed C-peptide negative
  • The subject/carer will have been an insulin pump user for at least 3 months, with good knowledge of insulin self-adjustment as judged by the investigator
  • The subject/carer is willing to perform regular finger-prick blood glucose monitoring, with at least 4 blood glucose measurements taken every day
  • HbA1c between 7.0% and 11.0 % (53 to 97mmol/mol) based on analysis from central laboratory or equivalent
  • The subject is literate in English
  • The subject is willing to wear closed-loop system at home and at school / college / work
  • The subject is willing to follow study specific instructions

Exclusion criteria

  • Non-type 1 diabetes mellitus including those secondary to chronic disease
  • Any other physical or psychological disease or condition likely to interfere with the normal conduct of the study and interpretation of the study results as judged by the investigator.
  • Current treatment with drugs known to have significant interference with glucose metabolism, such as systemic corticosteroids, as judged by the investigator
  • Known or suspected allergy against insulin
  • Subjects with clinically significant nephropathy, neuropathy or proliferative retinopathy as judged by the investigator
  • Significantly reduced hypoglycaemia awareness as judged by the investigator
  • Total daily insulin dose ≥ 2 IU/kg/day
  • Total daily insulin dose <10 IU/day
  • Reduced hypoglycaemia awareness
  • Pregnancy, planned pregnancy or breast feeding
  • Severe visual impairment
  • Severe hearing impairment
  • Subjects using implanted internal pacemaker
  • Lack of reliable telephone facility for contact

Treatment and study plan

Closed-loop system

Device

The closed-loop system is purpose-built and comprises a hand-held computer containing a model predictive control (MPC) based glucose control algorithm and communicating with the CGM device and the insulin pump.

real-time CGM

Device

Subject's glucose level is controlled by usual insulin pump therapy in conjunction with real time continuous glucose monitoring (CGM)

Primary outcomes

  1. The proportion of time spent in the target glucose range from 3.9 to 10.0 mmol/l based on CGM

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

Secondary outcomes

  1. The proportion of time spent above and below the target glucose (3.9 to 10.0 mmol/l) based on CGM.

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

  2. The proportion of time with glucose levels < 3.5 mmol/l and <2.8 mmol/l based on CGM

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

  3. The proportion of time with glucose levels in significant hyperglycaemia, as based on CGM (glucose levels > 16.7 mmol/l)

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

Other outcomes

  1. Safety evaluation

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

    Safety evaluation will comprise the number of episodes of hypoglycaemia, severe hypoglycaemia as well as nature and severity of any other adverse events, including ketone-positive hyperglycaemia.

  2. Utility evaluation

    Time frame: 7 day (phase 1) and 21 day (phase 2) home study periods

    Utility of the system will be evaluated by the frequency and duration of use of the closed-loop system at home.

Sponsors and collaborators

Lead sponsor

University of Cambridge

Other

Collaborators

  • Cambridge University Hospitals NHS Foundation Trust

Registry information

Official study title

An Open-label, Single-centre, Randomised, Two-period Crossover Study to Assess the Efficacy, Safety and Utility of Automated Closed-loop Glucose Control, Day and Night Over 7 Days (Phase 1) and 21 Days (Phase 2) in Comparison With Continuous Subcutaneous Insulin Infusion Combined With Continuous Glucose Monitoring in the Home Setting in Children and Adolescents T1D

Acronym: DAN04

Important dates

Study start
2014
Primary completion
2015
Study completion
2016
First posted
Jun 7, 2013
Registry last updated
Mar 3, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.