heart rate Control to Range System (hrCTR) using DiAs Platform
DeviceDiabetes Assistant (DiAs) Medical Platform System
- A smart-phone medical platform (DiAs);
- Continuous Glucose Monitor;
- Insulin pump;
- Bluetooth connection;
- Remote Monitoring Server.
NCT Number: NCT01945060
The purpose of this study is to see if the Artificial Pancreas (AP) Platform can successfully control blood sugar in people with type 1 diabetes mellitus on insulin pump therapy in a hospital setting. Investigators will also be studying to see if the heart rate informed Control To Range (hrCTR) can improve the performance of the system during and immediately after exercise.
Looking for future studies?
Notify Me12 year–17 year
All sexes
Interventional
Not applicable
University of Virginia Center for Diabetes Technology, Charlottesville, Virginia, United States
The artificial pancreas (AP), known as Closed-Loop Control of blood glucose in diabetes, is a system combining a continuous glucose monitor (glucose sensor), a control algorithm (complex mathematical formulas), and an insulin pump. The algorithms are intended to maintain your blood glucose level within a certain range. This is called Control-to-Range. The algorithms are intended to maintain your blood glucose level within a certain range. The algorithms run on a portable AP platform on an Android smart phone, called the Diabetes Assistant (DiAs) Medical Platform.
In this study, researchers hypothesize that the heart rate informed Control To Range (hrCTR) will limit the risk for hypo and hyperglycemia during and immediately after exercise in adolescents 12 - 17 years of age and assess if the hrCTR will improve additional measures of overall short term glycemic control in this population.
This trial will be performed at both Virginia Commonwealth University and the University of Virginia. IRB approvals have been obtained at both institutions.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
In addition, all subjects will meet the following additional criteria:
Exclusion criteria
Diabetes Assistant (DiAs) Medical Platform System
Not informing system of heart rate during exercise.
Time frame: 24 hours
The Low Blood Glucose Index, which quantifies the risk for hypoglycemia, and the hypoglycemic count (number sequences of blood glucose less than 70 mg/dL). The LBGI is a metric of the frequency and severity of hypoglycemia, based on an increasing weighting of progressively low glucose readings. The LBGI is measured on a scale from 0 to 100 and a higher score indicates a worse outcome.
Marc Breton
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07696039
Autoimmune Diseases, Diabetes Mellitus
Bergamo, Italy
View Trial DetailsNCT03263494
Autoimmune Diseases, Diabetes Mellitus
Los Angeles, California, United States
View Trial DetailsNCT07090824
Autoimmune Diseases, Diabetes Mellitus
Palo Alto, California, United States
View Trial DetailsNCT05211479
Adolescent, Anxiety Disorders
Yalova, Turkey (Türkiye)
View Trial Details