High definition colonoscopy (standard colonoscopy) in Adenoma Detection Rate
Diagnostic TestIn the intervention of this arm the investigators will apply the standard colonoscopy without computer-aided colonoscopy (polyDeep)
NCT Number: NCT05513261
This study is a clinical validation of PolyDeep, a computer-aided polyp detection (CADe) and characterization (CADx) system. PolyDeep Advance 3 is a multicentric randomized clinical trial comparing high definition colonoscopy with PolyDeep assisted high definition colonoscopy. The hypothesis of the study is that the PolyDeep assisted colonoscopy increases the Adenoma Detection Rate (ADR).
Looking for future studies?
Notify Me40 year–79 year
All sexes
Interventional
Not applicable
Complexo Hospitalario Universitario de Ourense, Ourense, Spain
Colorectal cancer (CRC) is the most frequently cancer in western world. A fundamental tool for detection and prevention is the colonoscopy. The detection and endoscopic resection of colorectal polyps, the precursor lesion of CRC, can reduce CRC incidence and mortality. Adenoma Detection Rate is the most used endoscopic quality indicator. The improvement of this indicator is related to the reduction of postcolonoscopy CRC incidence and mortality.
Colorectal polyp diagnosis is based on endoscopic resection and histological analysis. An accurate optical diagnosis could avoid histological lesion of smaller lesions, reducing the costs associated with histological diagnosis. The NICE (NBI International Colorectal Endoscopic) Classification has proposed use high definition endoscopes that have Narrow Band Imaging (NBI). However, NICE must be used by endoscopists who are sufficiently prepared and who have overcome the learning curve. Therefore, optical histology diagnosis with high accuracy independently of the center and the endoscopist is necessary.
Computer Aid Diagnosis (CAD) systems based on Artificial Intelligence are experiencing exponential development in the field of medical image analysis. The development of the CAD system is based on the creation of large databases of endoscopic images and/or videos, on the training, development and validation of diagnostic algorithms in such databases and, finally, on prospective clinical validation in patients undergoing colonoscopy. The goal of CAD systems in colonoscopy is double. First, the CAD system aims to increase the detection of polyps (CADe) in general, and of adenomas and serrated lesions in particular. The second objective is to characterize (CADx) the histology of detected lesion.
PolyDeep CAD is a functional prototype. This CAD system is capable of detecting, locating and classifying colorectal polyps. In vivo validation data shows that PolyDeep has high diagnostic accuracy for polyp identification and that this accuracy can be accommodated. The aim of PolyDeep advance 3 is to compare Adenoma Detection Rate differences in a randomized clinical trial. The investigators will compare the Adenoma Detection Rate between high definition colonoscopy and PolyDeep assisted high definition colonoscopy, both in CRC screening and surveillance.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
In the intervention of this arm the investigators will apply the standard colonoscopy without computer-aided colonoscopy (polyDeep)
In the intervention of this arm the investigators will apply polyDeep assisted high definition colonoscopy (CAD system).
Time frame: 1.5 years
Number of colonoscopies with adenomas/total number of colonoscopies. The investigators will evaluate if there are differences between both arms.
Time frame: 1.5 years
Number of colonoscopies with polyps/total number of colonoscopies. The investigators will evaluate if there are differences between both arms.
Time frame: 1.5 years
Number of colonoscopies with serrated lesions/total number of colonoscopies. The investigators will evaluate if there are differences between both arms.
Time frame: 1.5 years
Number of colonoscopies with advanced lesions (adenomas≥10mm, villous histology or high grade dysplasia; serrated lesions with dysplasia or ≥10mm) /total number of colonoscopies. The investigators will evaluate if there are differences between both arms.
Time frame: 1.5 years
Withdrawal time between the two arms will be calculated and compared by the investigators
Time frame: 1.5 years
The investigators will evaluate the optical diagnosis accuracy of Polydeep for the final histological diagnosis (sensitivity, specificity, positive and negative predictive values).
Fundacin Biomedica Galicia Sur
Other
PolyDeep Advance 3: Randomized Clinical Trial Comparing High Definition Colonoscopy With PolyDeep Assisted High Definition Colonoscopy.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT07725692
Anastomotic Leak, Colon Cancer
Alexandria, Please Select, Egypt
View Trial DetailsNCT07180303
Colonic Diseases, Colorectal Cancer
Liyang, Jiangsu, China
View Trial DetailsNCT03958747
Colonic Diseases, Colorectal Cancer
Winston-Salem, North Carolina, United States
View Trial Details