Standard technique First colonoscopy without PolyDeep
Diagnostic TestStandard technique First colonoscopy without PolyDeep
NCT Number: NCT05512793
This study is a clinical validation of PolyDeep, a computer-aided polyp detection (CADe) and characterization (CADx) system. PolyDeep Advance 2 is a multicentric randomized clinical trial with a tandem colonoscopy design. The hypothesis of this study is that Polydeep assisted colonoscopy will reduce the number of missed adenomas in the first withdrawal.
Looking for future studies?
Notify Me40 year–79 year
All sexes
Interventional
Not applicable
Complexo Hospitalario Universitario de Ourense, Ourense, Spain
Colorectal cancer (CRC) is the most frequently cancer in western world. A fundamental tool for detection and prevention is the colonoscopy. The detection and endoscopic resection of colorectal polyps, the precursor lesion of CRC, can reduce CRC incidence and mortality. Adenoma detection rate is the most used endoscopic quality indicator. The improvement of this indicator is related to the reduction of postcolonoscopy CRC incidence and mortality.
Colorectal polyp diagnosis is based on endoscopic resection and histological analysis. An accurate optical diagnosis could avoid histological lesion of smaller lesions, reducing the costs associated with histological diagnosis. The NICE (NBI International Colorectal Endoscopic) Classification has proposed the use of high definition endoscopes that have Narrow Band Imaging. However, NICE must be used by endoscopists who are sufficiently prepared and who have overcome the learning curve. Therefore, optical histology diagnosis with high accuracy independently of the center and the endoscopist is necessary.
Computer Aid Diagnosis (CAD) systems based on Artificial Intelligence are experiencing exponential development in the field of medical image analysis. The development of the CAD system is based on the creation of large databases of endoscopic images and/or videos, on the training, development and validation of diagnostic algorithms in such databases and, finally, on prospective clinical validation in patients undergoing colonoscopy. The goal of CAD systems in colonoscopy is double. First, it aims to increase the detection of polyps (CADe) in general, and of adenomas and serrated lesions in particular. The second objective is to characterize (CADx) the histology of detected lesion.
PolyDeep CAD is a functional prototype. It is capable of detecting, locating and classifying colorectal polyps. In vivo validation data shows that PolyDeep has high diagnostic accuracy for polyp identification and that this accuracy can be accommodated This clinical trial is part of the clinical validation of PolyDeep. We will perform a randomized clinical trial with a tandem colonoscopy design with adenoma miss rate as the main objective.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Standard technique First colonoscopy without PolyDeep
Combination technique First colonoscopy with PolyDeep
Time frame: 1 Year
AMR will be calculated as the number of adenomas detected on the withdrawal or portion in either group divided by the total number of adenomas detected during both withdrawals
Time frame: 1 Year
It will be calculated as the number of polyps detected on the withdrawal or portion in either group divided by the total number of polyps detected during both withdrawals
Time frame: 1 Year
It will be calculated as the number of serrated lesions detected on the withdrawal or portion in either group divided by the total number of serrated lesions detected during both withdrawals
Time frame: 1 Year
The diagnostic yield will be measure using sensitivity , specificity, Positive Predictive Value, Negative Predictive Value, likelihood ratios and Youden index. Histological diagnosis will be used as the gold standard.
Time frame: 1 Year
Withdrawal time between the two arms will be calculated and compared.
Fundacin Biomedica Galicia Sur
Other
PolyDeep Advance 2: Clinical Validation of PolyDeep. Randomized Clinical Trial with a Tandem Colonoscopy Design.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06068257
Breast Cancer, Breast Diseases
Orlando, Florida, United States
View Trial DetailsNCT07725692
Anastomotic Leak, Colon Cancer
Alexandria, Please Select, Egypt
View Trial DetailsNCT07180303
Colonic Diseases, Colorectal Cancer
Liyang, Jiangsu, China
View Trial DetailsNCT03958747
Colonic Diseases, Colorectal Cancer
Winston-Salem, North Carolina, United States
View Trial Details