Brooke Army Medical Center
Fort Sam Houston, Texas, 78234, United States
NCT Number: NCT02421094
A Randomized, Controlled, Double-blind, Parallel Group, Single Center Phase 2 Clinical Trial to Evaluate Multiple Non-Invasive Liver Fibrosis Imaging Methods in the Assessment of the Efficacy of GR-MD-02 for the Treatment of Liver Fibrosis in Patients with NASH with Advanced Fibrosis
Looking for future studies?
Notify Me18 year–75 year
All sexes
Interventional
Phase 2
Fort Sam Houston, Texas, 78234, United States
The primary objective is to determine the difference between placebo and GR-MD-02 treatment in the baseline adjusted mean change in liver fibrosis as measured by corrected T1 (cT1) mapping as determined from LiverMultiScan (LMS), a multi-parametric MRI protocol.
Secondary objectives include evaluating differences between subjects treated with GR-MD-02 versus placebo in:
An exploratory objective will be to evaluate the correlation of the three diagnostic modalities of LiverMultiScan, MR-Elastography, and FibroScan®.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
GM-MD-02 active
Other names: galactoarabino-rhamnogalacturonate
Placebo
Time frame: 16 weeks
Difference in baseline adjusted mean change in liver fibrosis of corrected T1 (cT1) mapping with LiverMultiScan (LMS).
LiverMultiScan is CE marked as a class IIa medical device. Corrected T1 (cT1) is a Magnetic Resonance (MR) relaxation parameter/measure from the device.The measure cT1 can be compared across different Magnetic Resonance Imaging (MRI) systems and sites. It is an emerging biomarker for rapid quantification of hepatic fibro-inflammatory disease. In unhealthy tissue, such as in inflamed and fibrotic tissues, measures result in longer cT1-relaxation.
Time frame: 16 weeks
Baseline-adjusted change in liver stiffness as measured by MR-elastography. Magnetic resonance elastography (MRE) is a technology that uses MRI imaging with low-frequency vibrations to create a visual map (elastogram) that shows stiffness of body tissues. Currently, MRE is used to detect stiffening of the liver caused by fibrosis and inflammation in chronic liver disease. Liver stiffness increases with liver damage/disease.
Time frame: 16 weeks
Baseline-adjusted change in liver stiffness as measured by FibroScan® scores. FibroScan measures scarring by measuring the stiffness of your liver. The fibrosis result is measured in kilopascals (kPa). It's normally between 2 and 6 kPa. Many people with liver disease(s) have a result that's higher than the normal range.
Galectin Therapeutics Inc.
Industry
Phase 2 Study to Evaluate Non-Invasive Imaging Methods in Efficacy Assessment of GR-MD-02 for the Treatment of Liver Fibrosis in Patients With NASH With Advanced Fibrosis
Acronym: NASH-FX
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04801849
Digestive System Diseases, Fatty Liver
La Jolla, California, United States
View Trial DetailsNCT02815891
Digestive System Diseases, Fatty Liver
Phoenix, Arizona, United States
View Trial DetailsNCT05877547
Digestive System Diseases, Fatty Liver
Chandler, Arizona, United States
View Trial DetailsNCT04971785
Digestive System Diseases, Fatty Liver
Birmingham, Alabama, United States
View Trial Details