Hospital Ramón y Cajal
Madrid, 28034, Spain
NCT Number: NCT04444076
This study aims a determine the effect that the addition of REGENETEN Bioinductive Implant has on Supraspinatus Tendon Repair. 120 patients will be included in this prospective, randomized, parallel group study.
This study is active but is not currently recruiting participants.
Notify Me18 year and older
All sexes
Interventional
Not applicable
Madrid, 28034, Spain
The rotator cuff tear is one of the most frequent pathologies in the shoulder joint. When there are many symptoms these breaks are repaired surgically. The success rate of healing of these injuries is between 30% and 80%. In two recent studies conducted at two of the centers participating in this trial, the success rate of repair was 75% (unpublished data) and 70% respectively.
The use of high porosity resorbable bovine collagen meshes as bioinductive scaffolds for cuff repair seems to be a valid alternative when trying to improve the success rate in the healing of rotator cuff injuries.
REGENETEN Bioinductive Implant (a high porosity reconstituted type I collagen mesh of bovine origin) is applied to the repaired tendon. In a pilot study of 9 subjects with full thickness supraspinatus ruptures who underwent tendon repair and subsequently had the implant associated with the rupture, a significant clinical improvement was observed after one year and was observed on magnetic resonance imaging ( RM) 100% healing of breaks. In a study of 33 subjects with partial thickness tears treated with the implant alone, improvement in MRI characteristics of the tendon was observed in 31 cases. There is a study that performs a histological analysis of samples obtained in 7 subjects in whom the implant was used. No evidence of foreign body reaction or inflammatory reaction was observed. In none of the three studies where said implant was used in humans were any complications or adverse effects related to the use of said implant observed.
The objective of the study is to evaluate the effect that the addition of REGENETEN bovine collagen mesh has on tendon repair on MRI performed one year after surgery.
The study does not in itself pose a greater risk than the usual practice for the patient, since in these subjects where the implant could be used as a supplement to the repair, having already obtained the CE marking.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
REGENETEN bioinductive Implant,a reconstituted bovine origin type I collagen mesh with a proprietary high porosity system that is commercialized sterile, dehydrated and desiccated in two sizes (20x26mm and 25x31mm). It will be implanted following supraspinatus tendon repair.
Time frame: 12 months
This is a classification system described by Sugaya et al. which uses magnetic resonance imaging in order to evaluate tendon integrity after rotator cuff repair. Postoperative cuff integrity is classified into 5 categories: type I, sufficient thickness with homogenously low intensity; type II, sufficient thickness with partial high intensity; type III, insufficient thickness without discontinuity; type IV, presence of minor discontinuity; type V, presence of major discontinuity
Time frame: 3 months, 6 months and 12 months after surgery
This item has a scale of 0 to 10 with 0 indicating "No pain" and 10 indicating "Pain as bad as you can imagine"
Time frame: 3 months, 6 months and 12 months after surgery.
The Constant-Murley Shoulder Score is a scoring method used by clinicians to assess function of the shoulder. The score is on a scale of 0 to 100, with 0 being no shoulder function and 100 being excellent function.
Time frame: 3 months, 6 months and 12 months after surgery.
The American Shoulder and Elbow Surgeons (ASES) questionnaire was developed to provide a standardized method for evaluating shoulder function and has been validated in patients with any array of shoulder pathologies. The range is from 0 to 100, with 0 being worst, and 100 being best.
Time frame: 3 months, 6 months and 12 months after surgery.
The Euro Quality of Life Five Dimensions 5 Level (EQ-5D-5L) questionnaire consists of two parts: a descriptive system and a Visual Analogue Scale.
The descriptive system describes the health state and consists of five dimensions: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. Patients who reported problems were then categorized into two categories, a "has no problem" category (health state code of 1) and "has problem" category (health state code of 2-5) for each level of each dimension.
The second part of the EQ-5D-5L questionnaire is the EQ-VAS, which is a thermometer-like scale (ranging from 0 to 100) that reflects the patient's health in general. EQ-VAS represents the patient perspective, where 0 indicates the worst imaginable health state and 100 reflects the best imaginable health state.
Time frame: 12 months
Rate of complications, including: infection, implant intolerance, readmission, reoperation, or fracture.
Fundacion para la Investigacion Biomedica del Hospital Universitario Ramon y Cajal
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT06851650
Rotator Cuff Injuries, Rotator Cuff Repair Rehabilition
Alexandria, Egypt
View Trial DetailsNCT07311616
Supraspinatus Tear
Beijing, Beijing Municipality, China
View Trial DetailsNCT05590494
Supraspinatus Tear
Onalaska, Wisconsin, United States
View Trial DetailsNCT05660031
Supraspinatus Tear
Ann Arbor, Michigan, United States
View Trial Details