NCT Number: NCT06565702
This study was a single-center, open-ended, self-controlled clinical study . Same armsequential method was used to measure the blood pressure of the subjects,inclusion of ≥85 subjects aged 12 years or older who met the enrollment criteria.In accordance with the "Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018/Amd 1:2020)",the purpose of this study was to compare the blood pressure and pulse rate measured by an electronic sphygmomanometer with those measured by a reference sphygmomanometer (an upper-arm noninvasive auscultatory sphygmomanometer) and by palpation of the radial artery, and then to evaluate the accuracy and safety of the measurement of systolic blood pressure, diastolic blood pressure, and pulse rate by a fully automated electronic sphygmomanometer for medical use (Model No. YE990), which is manufactured by Jiangsu Yuyue Medical Equipment Co.
Trial opening soon.
Get Notified12 year and older
All sexes
Observational
Hefei, Anhui, 230000, China
Hejun Liu
CONTACT
This study was a single-center, open-ended, self-controlled clinical study . Same armsequential method was used to measure the blood pressure of the subjects,inclusion of ≥85 subjects aged 12 years or older who met the enrollment criteria.In accordance with the "AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018/Amd 1:2020)",the purpose of this study was to compare the blood pressure and pulse rate measured by an electronic sphygmomanometer with those measured by a reference sphygmomanometer (an upper-arm noninvasive auscultatory sphygmomanometer) and by palpation of the radial artery, and then to evaluate the accuracy and safety of the measurement of systolic blood pressure, diastolic blood pressure, and pulse rate by a fully automated electronic sphygmomanometer for medical use (Model No. YE990), which is manufactured by Jiangsu Yuyue Medical Equipment Co.
(One) criteria for admission Inclusion Criteria
Subjects should meet all of the following requirements for inclusion in the study:
consent form after understanding the contents of the study. (6) Good compliance and ability to complete the clinical trial. 2. Exclusion Criteria
Subjects who fulfill any of the following requirements cannot be included in the study:
(Two)Evaluation methods 2.1. Evaluation of effectiveness According to the standard requirements of "AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018/Amd 1:2020)", the relationship between the mean value of the error and the standard deviation, the consistency between the measured and reference blood pressure values, and the relationship between the arm circumference and the measurement error should be evaluated.
2.2. Safety evaluation According to the "Code for Quality Management of Clinical Trials of Medical Devices" (2022) iii, medical devices should be collected and recorded when conducting clinical trials.
When conducting clinical trials of medical devices, the occurrence of adverse events and defects of the devices in the course of use by the subjects should be collected and recorded.
2.3. Evaluation of product performance Clinical use performance evaluation is mainly for product stability evaluation, the specific evaluation criteria are as follows, the following items if evaluation
If the evaluation of the following items is "yes", it is necessary to specifically describe the cause of the failure:
Evaluation item 1: electronic sphygmomanometer power on and off Yes: Cannot be turned on and/or off normally; No: can be turned on and off normally. Evaluation Item II: Whether the device automatically shuts off during the checking process Yes: Automatic shutdown during the inspection; No: There is no automatic shutdown during the inspection. Evaluation item 3: Whether there is any abnormal interruption due to the machine during the inspection process.
Yes: Abnormal interruptions occurred during the inspection process due to the machine; No: No abnormal interruptions occurred during the inspection. Evaluation item 4: Whether inflation and exhaust failures occurred during the inspection process Yes: Inflation and/or exhaust failure occurred during the inspection; No: No inflation and exhaust failure occurred during the inspection. Evaluation item 5: Whether air leakage occurred during the inspection process Yes: Air leakage occurred; No: no air leakage occurred.
(Three)Test medical device and control medical device
(Four)statistical analysis
maximum, upper quartile (Q1), and lower quartile (Q3); qualitative data were analyzed by describing the number of cases and their proportion of the total number of subjects.
The qualitative data were analyzed by describing the number of cases and their percentages.
Criterion 1: Calculate the mean and standard deviation of the errors of 255 sets of measured and reference blood pressure values of 85 subjects, and compare the systolic and diastolic blood pressures separately, with the mean value of the error not exceeding ±5 mmHg and the standard deviation not exceeding 8 mmHg.
Criterion 2: Comparison of the mean of the three sets of errors for each subject, comparing systolic and diastolic blood pressures separately.
Agreement between measured and reference blood pressure values (Bland-Altman analysis) According to ISO 81060-2:2018/Amd 1:2020, a scatter plot of the difference between the reference device and the device under test should be plotted for each occasion, and the difference between systolic and diastolic blood pressure should be plotted separately. x-axis indicates the mean value of the 2 methods of measurement for each subject, and y-axis indicates the difference between the 2 methods of measurement for each subject.
Relationship between arm circumference and measurement error (Bland-Altman analysis) Plot the results of all subjects by arm circumference according to ISO 81060-2:2018/Amd 1:2020 5.1.4 d. The x-axis shows the actual arm circumference of the subject and the y-axis shows the difference between the measured blood pressure value and the reference blood pressure value.
Pulse Rate Error The relative error of the pulse rate measurement is counted.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Subjects should meet all of the following requirements for inclusion in the study:
consent form after understanding the contents of the study.
Exclusion criteria
Subjects who fulfill any of the following requirements cannot be included in the study:
(1) Mental illness, impaired consciousness, or other conditions that prevent them from cooperating with the study; (2) Require hemodialysis; (3) Taking anticoagulant drugs for cardiovascular diseases; (4) Pregnant and lactating women; (5) Patients with cardiac arrhythmia; (6) Patients with peripheral arterial disease and diseases that may affect arterial compliance; (7) Other conditions that are considered by the physician to be unsuitable for enrollment.
-
Time frame: August 20, 2024 - December 30, 2025
Evaluate the relationship between the mean and standard deviation of error, the agreement between the measured and reference blood pressure values, and the relationship between arm circumference and measurement error.Reference standard: 255 sets of data from 85 subjects were calculated and compared separately for systolic and diastolic blood pressure, with a mean deviation of not more than ±5 mmHg and a standard deviation of not more than 8 mmHg.
Time frame: August 20, 2024 - December 30, 2025
Time frame: August 20, 2024 - December 30, 2025
Evaluation Item 1: Electronic Sphygmomanometer Turning On and Off Evaluation item 2: Whether the device was turned off automatically during the checking process Evaluation item 3: Whether there is any abnormal interruption due to the machine during the inspection process.
Evaluation item 4: Whether inflation and exhaust failure occurs during the inspection process Evaluation item 5: Whether air leakage occurred during the inspection process
Contact information is provided by the study sponsor or research team.
The First Affiliated Hospital of Anhui Medical University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07695883
Blood Pressure, Body Composition
Rangpur City, Bangladesh
View Trial DetailsNCT07687771
Blood Pressure
View Trial DetailsNCT07674511
Autonomic Nervous System Diseases, Blood Pressure
West Orange, New Jersey, United States
View Trial DetailsNCT07633392
Behavior, Blood Pressure
Santiago, Independencia, Chile
View Trial Details