Procedure: Patients lie prone on a table with the anterior superior iliac spine at the table edge. The upper body is suspended horizontally, arms crossed over the chest or extended parallel to the floor. Patients will maintain this posture for 90-120 seconds or until unable to continue (trunk angle deviation > 5°-10°). Surface electromyography (sEMG) signals will be collected synchronously, with three repetitions averaged.
Electrode Placement: Surface EMG (ME6000, Finland) will be used to collect sEMG signals. Electrodes (0.5 cm diameter, 2 cm spacing) will be placed at the L5-S1 level for multifidus (LM) and L4-L5 for erector spinae (LE) muscles. Reference electrodes will be positioned 3 cm laterally. Sampling rate is set at 1000 Hz, with a bandpass filter of 10-500 Hz and noise level < 3.5 μV.
Evaluation Metrics: Time-domain features and frequency-domain characteristics will be combined to report surface electromyography (sEMG) signals.