Ruijin Hospital, Affiliated to Shanghai Jiao Tong University School of Medicine
Shanghai, Shanghai Municipality, 200025, China
NCT Number: NCT07067372
Clinical study on the safety and efficacy of FireMagic™ Magbot Ablation Catheter for rapid arrhythmia
Trial opening soon.
Get Notified18 year–80 year
All sexes
Interventional
Not applicable
Shanghai, Shanghai Municipality, 200025, China
Explore the safety and efficacy of ireMagic™ Magbot Ablation Catheter for rapid arrhythmia in clinical studies, establish standards for standardised catheter use after market launch, and provide evaluation indicators that meet the requirements for nationwide multi-centre promotion.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
All patients signed informed consent forms, enrolled in the trial, underwent surgical treatment for rapid arrhythmia using XX, and were discharged after follow-up data collection. The total duration for each subject is estimated to be approximately 7 days.
Time frame: On the day of the surgery
Following the procedure, the following criteria are used to evaluate whether catheter ablation has achieved the intended surgical objectives:Ⅰ. AVNRT: AVNRT cannot be induced after ablation. If skipped beats or 1-2 atrial echoes are present, induction stimulation must be performed concurrently with an isoproterenol challenge test, and AVNRT still cannot be induced. Ⅱ.AVRT: ① AVRT cannot be induced after ablation; ② ventricular stimulation shows central VA Wenckebach conduction or VA dissociation; ③ atrial stimulation shows central AV Wenckebach conduction.
Observe for 20-30 minutes after initial pulmonary vein isolation and verify successful bidirectional block.
Time frame: Statistics Perioperative
Calculate the incidence rate of any major adverse events occurring within 7 days after each atrial fibrillation ablation procedure (including initial and repeat procedures) using the study device.
Contact information is provided by the study sponsor or research team.
Shanghai MicroPort EP MedTech Co., Ltd.
Industry
Clinical Study on the Safety and Efficacy of FireMagic™ Magbot Ablation Catheter for Rapid Arrhythmia
Acronym: Rapid arrhythm
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07032948
Arrhythmias, Cardiac, Atrial Fibrillation
View Trial DetailsNCT06686485
Arrhythmias, Cardiac, Atrial Fibrillation
Suzhou, Jiangsu, China
View Trial DetailsNCT07149545
Arrhythmias, Cardiac, Atrial Fibrillation
Beijing, Beijing Municipality, China
View Trial DetailsNCT07625215
Arrhythmias, Cardiac, Atrial Fibrillation
San Francisco, California, United States
View Trial Details