Concordia Dent Clinic
Bucharest, 041335, Romania
NCT Number: NCT01034930
The aim of the investigators study is to compare, in a prospective controlled clinical trial, the Locator® System with two other types of stress-breaking retention (Retentive Anchors and Magnets) for implant supported overdenture in atrophic edentulous mandible, with the use of Straumann Dental Implant System.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Bucharest, 041335, Romania
The study was divided in two parts - in the first part of the study 46 fully mandibular edentulous patients will be enrolled. The patients will be recruited from the University Hospital of Dentistry and 9 other private practices in Bucharest and surrounding areas.
Selected patients will be informed about the two different treatment options, about the benefit of treatment with an overdenture retained by two endosseous implants and a written informed consent will be obtained from all participants.
Initial examination
At the beginning of the treatment for each patient will be recorded:
Treatment procedure Each patient will receive 2 screw-type Straumann (Institut Straumann AG, Basel, Switzerland) standard implants Ø4.1 mm, with SLA surface in the canine region of the mandible with an interconnecting line approaching parallelism with the terminal mandibular hinge axis. The implant lengths will be 10mm and 12mm. The choice of implant length will be dictated by the preoperative radiographic assessment of bone height in the canine region and drilling distance with the principal concern achieving primary stability.
The implants will be inserted under local anaesthesia using a surgical template derived from a tooth wax-up. The implants will be placed in a 1-stage non-submerged procedure according to a strict protocol (Weingart D and ten Bruggenkate 2000). Postoperatively, antibiotics for 5 days treatment (Amoxicillin and Clavulanate Potassium or Erytromycin - for patients alergic to Penicillin), analgesics and Clorhexidine 0,12% mouth rinse will be prescribe for 14 days. Patients will not be allowed to wear the mandibular denture during the first two weeks post-operatively.
One, two and four weeks after the surgical procedure, the patients will be recalled for follow-up visits. At the first recall visit, sutures will be removed. At the second visit the lower denture will be adjusted by selective grinding at the implant location, and Protefix® (Queisser Pharma Germany) Adhesive Cushions will be provided for patients. At all recall visits, patients will receive oral hygiene instructions.
At the third follow-up visit the manufacturing of a new maxillary denture (for the full maxillary edentulous patients) and a mandibular over-denture will be initiated.
After 6 weeks healing period implants will be loaded and the patients will be randomly assigne to one of two main groups:
Group B will be randomly divided in two subgroups: full lower denture with two gold matrices with variable retention (four lamellae functioning like a spring - 12 patients and full lower denture with two titanium matrices with defined retention (spring with a defined extraction force of 700-1100g - B.2) - 11 patients. A new mandibular overdenture with metal reinforcement will be made.
The two groups of patients will be compared in the second part of the study with 23 patients receiving Locator system abutments (Group L) following same research protocol.
A new mandibular overdenture with metal reinforcement will be made.
The prosthetic procedure will be performed according the recommendations of the producer (Straumann Dental Implant System) for retentive anchors, magnets and Locator System by experienced prosthodontists. The occlusion will be assessed on the articulator and intra-orally to secure a balanced occlusion in centric relation without anterior tooth contact.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Each patient will receive 2 screw-type Straumann (Institut Straumann AG, Basel, Switzerland) standard implants Ø4.1 mm, with SLA surface in the canine region of the mandible with an interconnecting line approaching parallelism with the terminal mandibular hinge axis, according to a standard surgical protocol.
Other names: Mandibular overdenture metal reinforced will be made.
Time frame: 5 years
Time frame: 5 years
Time frame: 5 years
Concordia Dent Srl
Other
A 5-year Prospective Randomised Clinical Study on the Efficiency of Three Different Attachment Systems as Retention for Implant-supported Mandibular Overdenture.
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07245758
Congenital Abnormalities, Congenital, Hereditary, and Neonatal Diseases and Abnormalities
Charleston, South Carolina, United States
View Trial DetailsNCT04446078
Dental Implants, Dental Materials
Lisbon, Portugal
View Trial DetailsNCT01147315
Mandible, Osteoradionecrosis
Nantes, France
View Trial DetailsNCT07727980
Clinical Trials, Dental Implant
Chicago, Illinois, United States
View Trial Details