Skip to main content
OpenTrials
Completed

NCT Number: NCT02190578

Clinical Performance of Reveal G4 Rapid HIV-1 Antibody Test

To determine the efficacy of an improved rapid diagnostic test using venous whole blood and fingerstick whole blood. The clinical performance of Reveal G4 Rapid HIV-1 Antibody Test will be determined by comparing the results with patient infected status for HIV-1 (human immunodeficiency virus type 1).

The study will consist of a single one-hour visit, at which time blood samples will be collected and tested with the investigational device (Reveal G4) and FDA approved comparator assays for detection of HIV-1 antibodies.

Completed

Looking for future studies?

Notify Me

Key information

Age range

13 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Preventive Medicine, University of Southern California (Los Angeles), Los Angeles, California, United States

Loading trial locations.

About this study

This clinical trial is a multi-center study to assess the performance characteristics of a rapid in vitro diagnostic assay, the Reveal G4 Rapid HIV-1 Antibody Test (Reveal G4). Specifically, the objective of this study is to determine the sensitivity and specificity of Reveal G4 in finger stick and venous whole blood, relative to FDA approved reference assays for the detection of HIV-1 antibodies.

Approximately 1500-2000 subjects in total will be enrolled in the study across all sites, into three different study populations. Population 1 will be comprised of at least 500 subjects from a population at risk of infection with HIV. Population 2 will be comprised of at least 500 subjects that are known HIV positive individuals. Population 3 will be comprised of at least 500 subjects from a population at low risk of HIV infection. Reveal G4 will be used to test fingerstick whole blood and venous whole blood samples from all study subjects. For enrolled subjects in Populations 1 and 3, who are of unknown HIV antibody status, a plasma sample prepared from the venous whole blood sample will also be tested with an algorithm of FDA-approved assays for the detection of HIV-1 antibodies. For Population 2 subjects who are known HIV-positive individuals, results of previous HIV tests will be obtained from the subjects' medical records. The sensitivity and specificity of Reveal G4 will be determined in fingerstick and venous whole blood relative to HIV-1 antibody status as determined by an algorithm of FDA-approved assays.

The primary analysis will involve comparison of Reveal G4 results for anti-HIV-1 in each sample matrix (fingerstick whole blood and venous whole blood) with the subject's HIV-1 antibody status as determined by FDA-approved assays. Based on the above, the sensitivity and specificity of Reveal G4 will be determined with corresponding two-sided 95% confidence intervals for both fingerstick and venous whole blood.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • All subjects must be at least 18 years of age, able to sign consent form, complete the risk assessment questionnaire, and provide the required blood samples: fingerstick sample (1 drop), venous whole blood sample (1 K2 EDTA tube).
  • Population 1 - Individuals at risk of HIV infection (n ≥ 500) Subjects must meet have at least one risk factor for infection with HIV
  • Population 2 - Known HIV-1 positive individuals (n ≥ 500) Subjects must be a known HIV-positive individual (previous positive HIV test result)
  • Population 3 - Individuals at low risk of HIV infection (n ≥ 500) Subjects must not have any risk factors for infection with HIV

Exclusion criteria

  • Subjects do not meet inclusion criteria

Treatment and study plan

Reveal G4

Device

All subjects tested with the investigational device, Reveal G4, plus with an algorithm of approved assays for HIV.

Other names: Reveal Rapid HIV-1 Antibody Test

Primary outcomes

  1. Determine clinical performance of Reveal G4

    Time frame: At single study visit (one hour)

    To determine the clinical performance of Reveal G4 with fingerstick and venous whole blood relative to the HIV-1 infected status of the patient

Sponsors and collaborators

Lead sponsor

MedMira Laboratories Inc.

Industry

Registry information

Official study title

Clinical Performance of Reveal G4 Rapid HIV-1 Antibody Test for the Detection of HIV-1 Antibodies in Fingerstick and Venous Whole Blood Samples

Important dates

Study start
2014
Primary completion
2015
Study completion
2015
First posted
Jul 15, 2014
Registry last updated
Apr 24, 2015