Reveal G4
DeviceAll subjects tested with the investigational device, Reveal G4, plus with an algorithm of approved assays for HIV.
Other names: Reveal Rapid HIV-1 Antibody Test
NCT Number: NCT02190578
To determine the efficacy of an improved rapid diagnostic test using venous whole blood and fingerstick whole blood. The clinical performance of Reveal G4 Rapid HIV-1 Antibody Test will be determined by comparing the results with patient infected status for HIV-1 (human immunodeficiency virus type 1).
The study will consist of a single one-hour visit, at which time blood samples will be collected and tested with the investigational device (Reveal G4) and FDA approved comparator assays for detection of HIV-1 antibodies.
Looking for future studies?
Notify Me13 year and older
All sexes
Interventional
Not applicable
Preventive Medicine, University of Southern California (Los Angeles), Los Angeles, California, United States
This clinical trial is a multi-center study to assess the performance characteristics of a rapid in vitro diagnostic assay, the Reveal G4 Rapid HIV-1 Antibody Test (Reveal G4). Specifically, the objective of this study is to determine the sensitivity and specificity of Reveal G4 in finger stick and venous whole blood, relative to FDA approved reference assays for the detection of HIV-1 antibodies.
Approximately 1500-2000 subjects in total will be enrolled in the study across all sites, into three different study populations. Population 1 will be comprised of at least 500 subjects from a population at risk of infection with HIV. Population 2 will be comprised of at least 500 subjects that are known HIV positive individuals. Population 3 will be comprised of at least 500 subjects from a population at low risk of HIV infection. Reveal G4 will be used to test fingerstick whole blood and venous whole blood samples from all study subjects. For enrolled subjects in Populations 1 and 3, who are of unknown HIV antibody status, a plasma sample prepared from the venous whole blood sample will also be tested with an algorithm of FDA-approved assays for the detection of HIV-1 antibodies. For Population 2 subjects who are known HIV-positive individuals, results of previous HIV tests will be obtained from the subjects' medical records. The sensitivity and specificity of Reveal G4 will be determined in fingerstick and venous whole blood relative to HIV-1 antibody status as determined by an algorithm of FDA-approved assays.
The primary analysis will involve comparison of Reveal G4 results for anti-HIV-1 in each sample matrix (fingerstick whole blood and venous whole blood) with the subject's HIV-1 antibody status as determined by FDA-approved assays. Based on the above, the sensitivity and specificity of Reveal G4 will be determined with corresponding two-sided 95% confidence intervals for both fingerstick and venous whole blood.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
All subjects tested with the investigational device, Reveal G4, plus with an algorithm of approved assays for HIV.
Other names: Reveal Rapid HIV-1 Antibody Test
Time frame: At single study visit (one hour)
To determine the clinical performance of Reveal G4 with fingerstick and venous whole blood relative to the HIV-1 infected status of the patient
MedMira Laboratories Inc.
Industry
Clinical Performance of Reveal G4 Rapid HIV-1 Antibody Test for the Detection of HIV-1 Antibodies in Fingerstick and Venous Whole Blood Samples
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05149001
Behavior, Blood-Borne Infections
Aix-en-Provence, France
View Trial DetailsNCT05732675
Behavior, Bisexuality
Ho Chi Minh City, Vietnam
View Trial DetailsNCT07750834
Acquired Immunodeficiency Syndrome, Behavior
Khartoum, Omdurman, Sudan
View Trial DetailsNCT06012136
Acquired Immunodeficiency Syndrome, Blood-Borne Infections
Las Vegas, Nevada, United States
View Trial Details