Skip to main content
OpenTrials
Completed

NCT Number: NCT02131402

Clinical Performance of Hydrogel vs. Silicone Hydrogel Contact Lenses

The aim of this non-dispensing fitting study is to evaluate the subjective comfort, lens handling, lens fitting characteristics and visual acuity of different hydrogel lens designs versus silicone hydrogel lenses

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–40 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Optometry Research Group (GIO) Optics Department, University of Valencia

Valencia, 46100, Spain

About this study

This is a 60-subject, double masked, randomized, contra lateral, non-dispensing fitting trial comparing different lens materials (hydrogel vs silicone hydrogel). It is anticipated that this study will involve 2 visits, for each lens pair, as follows: Visits: V1 (lens dispensing), V2 (1 hour post lens settling). Each subject will be randomized to wear the test and control lenses in a series of three short fitting comparisons.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Is between 18 and 40 years of age (inclusive)
  • Has had a self-reported visual exam in the last two years
  • Is an adapted soft CL (Contact Lens) wearer
  • Has a CL spherical prescription between - 1.00 and - 10.00 (inclusive)
  • Has a spectacle cylinder up to 0.75D (Diopter) in each eye.
  • Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye.
  • Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses.
  • Has clear corneas and no active ocular disease
  • Has read, understood and signed the information consent letter
  • Patient contact lens refraction should fit within the available parameters of the study lenses
  • Is willing to comply with the wear schedule
  • Is willing to comply with the visit schedule

Exclusion criteria

  • Has never worn contact lenses before.
  • Currently wears rigid gas permeable contact lenses.
  • Has a history of not achieving comfortable CL wear (5 days per week; > 8 hours/day)
  • Has a CL prescription outside the range of - 1.00 to -10.00D
  • Has a spectacle cylinder ≥1.00D of cylinder in either eye.
  • Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye.
  • Presence of clinically significant (grade 2-4) anterior segment abnormalities.
  • Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear.
  • Slit lamp findings that would contraindicate contact lens wear such as:
  • Pathological dry eye or associated findings
  • Pterygium, pinguecula, or corneal scars within the visual axis
  • Neovascularization > 0.75 mm in from of the limbus
  • Giant papillary conjunctivitis (GCP) worse than grade 1
  • Anterior uveitis or iritis (past or present)
  • Seborrheic eczema, Seborrheic conjunctivitis
  • History of corneal ulcers or fungal infections
  • Poor personal hygiene
  • Has a known history of corneal hypoesthesia (reduced corneal sensitivity)
  • Has aphakia, keratoconus or a highly irregular cornea.
  • Has Presbyopia or has dependence on spectacles for near work over the contact lenses.
  • Has undergone corneal refractive surgery.
  • Is participating in any other type of eye related clinical or research study.

Treatment and study plan

ocufilcon D

Device

Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (ocufilcon D) in the contra lateral eye.

Other names: Hydrogel Contact Lens

omafilcon A

Device

Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (omafilcon A) in the contra lateral eye.

Other names: Hydrogel Contact Lens

methafilcon A

Device

Contralateral pair of study lenses. Test lens (enfilcon A) in one eye and a control lens (methafilcon A) in the contra lateral eye.

Other names: Hydrogel Contact Lens

Primary outcomes

  1. Participant's Subjective Rating for Lens Handling - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1 (1 hour). Rated by questionnaires (0= Very difficult 0-100, 100= very easy).

  2. Participant's Subjective Rating for Lens Handling - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Surveyed after 1 hour of lens wear for each lens at lens removal for Pair #2 (1 hour). Rated by questionnaires (0=Very difficult 0-100, 100= very easy).

  3. Participant's Subjective Rating for Lens Handling - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour of lens wear for each lens at lens removal Pair #3. Rated by questionnaires (0-100 0=Very difficult, 100= very easy).

  4. Participants Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D

    Time frame: Baseline

    Surveyed after insertion of each lens Pair #2 (at insertion). Rated by Questionnaire (0-100,0=Can't be worn and causes pain, 100=can't feel).

  5. Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A

    Time frame: Baseline

    Surveyed after insertion of each lens at baseline visit for Pair #1. Rated by questionnaires (0-100, 0-Can't be worn and causes pain,100= can't feel).

  6. Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A

    Time frame: Baseline

    Surveyed after insertion Pair #3 (baseline). Rated by questionnaires (0-100, 0-Can't be worn, 100= can't feel).

  7. Participant's Subjective Rating for Lens Comfort - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #1. Rated by questionnaires (0-100, 0= Can't be worn and causes pain, 100= can't feel).

  8. Participant's Subjective Rating for Lens Comfort - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100 0=Can't be worn and causes pain, 100= can't feel).

  9. Participant's Subjective Rating for Lens Comfort - Enfilcon A / Methafilcon A

    Time frame: 1 hours post settling

    Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0=Can't be worn and causes pain 100= can't feel).

  10. Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A

    Time frame: Baseline

    Surveyed after insertion of each lens Pair #1 at (Baseline visit). Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).

  11. Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D

    Time frame: Baseline

    Surveyed at insertion of each lens Pair #2 by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).

  12. Participants Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A

    Time frame: Baseline

    Surveyed after insertion of each lens for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).

  13. Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling (1 hour) of lens wear for Pair #1. Rated by subjects preference for test lens or control lens (Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Omafilcon A, Strong Omafilcon A).

  14. Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #2. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Ocufilcon D, Strong Ocufilcon D).

  15. Participant's Subjective Rating for Lens Comfort Preference - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #3. Rated by questionnaire (4 possible ratings: Strong Enfilcon A, Slight Enfilcon A, No preference, Slight Methafilcon A, Strong Methafilcon A).

  16. Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)

  17. Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #2. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)

  18. Eye Care Practitioner's Objective Assessment of Lens Fit, Post-blink Movement, and Primary Gaze Lag - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #3. (0-4, 0=Insufficient, unacceptable movement, 1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement)

  19. Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling of lens wear for Pair #1. Slit lamp. (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).

  20. Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #2, (0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support).

  21. Eye Care Practitioner's Objective Assessment of Lens Fit, Tightness Push-up Test - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #3. (Scale 0%-100%, 0%-100%, continuous scale where 100%=no movement, 50%=optimum, 0%=Falls from cornea without lid support)

  22. Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling of lens wear for Pair #1. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable).

  23. Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #2. (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)

  24. Eye Care Practitioner's Objective Assessment of Lens Fit, Centration - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Assessed after 1 hour post settling for Pair #3, (4 possible ratings: optimum, Decentration acceptable, Decentration unacceptable)

  25. Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A

    Time frame: Baseline

    Surveyed after insertion of each lens for Pair #1 at baseline visit. Rated by questionnaires (0-100, 0=no sensation of stinging/burning, 100= extreme stinging).

  26. Participant Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D

    Time frame: Baseline

    Surveyed after insertion of each lens Pair #2 at baseline. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging)

  27. Participant Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A

    Time frame: Baseline

    Surveyed after insertion of each lens for Pair #3. Rated by questionnaires (0-100,0=no sensation of stinging/burning, 100=extreme stinging).

  28. Participants Subjective Rating for Stinging/Burning - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour of lens wear for each lens at lens removal Pair #1. Rated by questionnaires (0-100,0=no sensation of stinging/burning 100=extreme stinging).

  29. Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #2. Rated by questionnaires (0-100,0= no sensation of stinging/burning, 100= extreme stinging).

  30. Participant's Subjective Rating for Stinging/Burning - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Surveyed after 1 hour post settling for Pair #3. Rated by questionnaires (0-100,0= no sensation of stinging/burning,100= extreme stinging).

  31. Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Omafilcon A

    Time frame: 1 hour post settling

    Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs Pair #1. LogMAR Visual Acuity (VA) to nearest letter)

  32. Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Ocufilcon D

    Time frame: 1 hour post settling

    Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #2. LogMAR Visual Acuity (VA) to nearest letter)

  33. Eye Care Practitioner's Objective Assessment of Binocular High Contrast Distance Visual Acuity - Enfilcon A / Methafilcon A

    Time frame: 1 hour post settling

    Visual acuity assessed after insertion of each study lens, prior to dispensing contralateral pairs- Pair #3. LogMAR Visual Acuity (VA) to nearest letter)

Sponsors and collaborators

Lead sponsor

CooperVision, Inc.

Industry

Registry information

Official study title

Non-Dispensing Fitting Study Comparing the Clinical Performance of Hydrogel vs. Silicone Hydrogel Sphere Design Contact Lenses

Important dates

Study start
2014
Primary completion
2014
Study completion
2014
First posted
May 6, 2014
Registry last updated
Apr 4, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.