DeviceThe Zimmer TM glenoid will be used for the glenoid shoulder replacement component.
Other names: Zimmer Trabecular Metal Glenoid
NCT Number: NCT01539122
The objective of this randomized controlled study is to obtain outcomes data on the Zimmer TM glenoid component by analysis of standard scoring systems and radiographs in comparison to the cemented glenoid component. In addition, the investigators plan to provide cost analysis based on the economic data collected to justify the cost difference between both implants.
Patients with acceptable glenoid bone stock will be randomized into two groups to be treated with either a TM Glenoid or cemented glenoid component with minimum 2 years follow-up; maximum 10 years follow-up.
Hypothesis: The early and long-term clinical outcomes and radiographic analysis of the TM glenoid components are superior to the cemented glenoid components in total shoulder arthroplasty patients.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Interventional
Not applicable
Kelowna General Hospital, Kelowna, British Columbia, Canada
Total shoulder arthroplasty is successful in relieving pain and restoring function to the joint, but chronic loosening of the glenoid implant remains a common complication. The Zimmer Trabecular Metal (TM) Glenoid is a monoblock implant for reconstructive total shoulder arthroplasty. To date, no published clinical data is available to confirm evidence on the effectiveness of this specific product.
The purpose of this prospective study is to obtain both short and long-term clinical outcomes data on the Zimmer TM Glenoid by analysis of standard scoring systems and radiographic analysis. The TM Glenoid Component is intended to function within Zimmer, Inc.'s Bigliani/Flatow (B/F) Complete Shoulder Solution. The device is a monoblock glenoid component comprised of a Trabecular Metal base, and is designed to interface and articulate with Zimmer, Inc.'s B/F humeral components. The Trabecular Metal Glenoid is designed with an articular surface that is manufactured from ultra-high molecular weight polyethylene (UHMWPE). The base of the implant has a cruciate TM keel that provides stability and initial fixation using a press-fit between the implant and the bone. Long-term fixation is provided by biological ingrowth into the TM material. Surgical fixation of the trabecular metal device will be obtained via press-fit. Surgical fixation of the comparison all-polyethylene glenoid component will be with Palacos/CoPal bone cement
This is a multi-centre, randomized controlled study to evaluate the clinical and radiological performance of the TM Glenoid in a series of patients with adequate glenoid bone stock receiving a total shoulder replacement. The comparison group will be a consecutive series of randomized patients with implanted cemented all-polyethylene glenoid component. This study will be descriptive in nature and seeks to demonstrate the superiority (or non-inferiority) of the TM Glenoid over cemented all-polyethylene glenoid components.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The Zimmer TM glenoid will be used for the glenoid shoulder replacement component.
Other names: Zimmer Trabecular Metal Glenoid
A cemented glenoid will be used for the glenoid component of the total shoulder replacement.
Other names: Cemented all-polyethylene glenoid component (Zimmer)
Time frame: 6 weeks, 3 mo, 6 mo, 1 yr, 2 yr, 3 yr, 4 yr, 5 yr post-op
The WOOS will be done at 6 weeks, 3 months, 6 months and yearly post-op to compare with the baseline pre-op score.
Time frame: 6 weeks, 3 mo, 6 mo, 1 yr, 2 yr, 3 yr, 4 yr, 5 yr post-op
The ASES will be done at 6 weeks, 3 months, 6 months and yearly post-op to compare with the baseline pre-op score.
Time frame: 6 weeks, 3 mo, 6 mo, 1 yr, 2 yr, 3 yr, 4 yr, 5 yr post-op
The SF-12 will be done at 6 weeks, 3 months, 6 months and yearly post-op to compare with the baseline pre-op score.
Time frame: 6 weeks, 3 mo, 6 mo, 1 yr, 2 yr, 3 yr, 4 yr, 5 yr post-op
The Health Resource Utilization Instrument will be done at 6 weeks, 3 months, 6 months and yearly post-op to gather data on the associated costs of the respective surgeries.
Time frame: post-op day 0 or 1, 6 weeks, 3 months, 6 months, 1 yr, 2 yr, 3 yr, 4 yr, 5 yr post-op
Grashey A-P and axillary views to assess component position, metallic debris, and radiolucency in 6 zones post op.
Joint Preservation Centre of BC
Other
A Multi-Centre, Randomized Controlled Study on the Zimmer TM Glenoid Component Compared to Cemented Glenoid Component
Acronym: TMGlenoid
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03382262
Arthritis, Joint Diseases
El Cajon, California, United States
View Trial DetailsNCT00479687
Arthritis, Joint Diseases
View Trial DetailsNCT02052206
Arthritis, Complexe Proximal Humeral Fractures
Zurich, Switzerland
View Trial DetailsNCT04468178
Arthritis, Joint Diseases
Hanover, Lower Saxony, Germany
View Trial Details