CyPass Micro-Stent
DeviceSmall tube with a through-lumen designed to redirect aqueous fluid from the front to the back of the eye in order to reduce intraocular pressure. Designed to be permanently implanted in the eye.
Other names: Model 2FX
NCT Number: NCT02448875
The purpose of this study is to assess the safety and effectiveness of the use of visco-assisted CyPass® Micro-Stent implantation for the lowering of intraocular pressure (IOP) in subjects who have open angle glaucoma (OAG).
Looking for future studies?
Notify Me21 year and older
All sexes
Interventional
Not applicable
Transcend Medical Investigative Site, Lübeck, Germany
The study was conducted in 2 phases. Only one eye per subject was treated for each independent phase.
Dose Selection Phase (Cohort 1): Subjects were randomized in a 1:1:1 ratio and implanted with either a CyPass Micro-Stent with targeted delivery of 30 microliters (μl) ophthalmic 5 viscoelastic, a CyPass Micro-Stent with targeted delivery of 60 μl of ophthalmic viscoelastic, or a CyPass Micro-Stent without adjunct viscoelastic in the study eye.
Expansion Phase (Cohort 2): Subjects were randomized in a 1:1 ratio and implanted with either the CyPass Micro-Stent without adjunct viscoelastic or the CyPass Micro-Stent with 60 μl of ophthalmic viscoelastic (based on Dose Selection results). Subjects were randomized to treatment on the day of their surgical procedure. A total of 9 scheduled visits were planned including Screening (Day -45 to -2), Baseline (Day -15 to -1), Surgery (Day 0), 1 Day (Day 1), 1 Week (Day 5-9), 1 Month (Day 21-35), 3 Month (Day 70-98), 6 Month (Day 150-210), and 12 Month (Day 330-420) visits. The total expected duration of participation for each subject was up to 13 months.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Small tube with a through-lumen designed to redirect aqueous fluid from the front to the back of the eye in order to reduce intraocular pressure. Designed to be permanently implanted in the eye.
Other names: Model 2FX
Healon 5 ophthalmic viscoelastic used to increase the size of the aqueous drainage area created by the CyPass Micro-Stent
Time frame: Baseline (Day -1), Month 12 PostOperative
IOP (fluid pressure inside the eye) was assessed using Goldmann applanation tonometry and reported in millimeters of mercury (mmHg). A higher IOP can be a greater risk factor for developing glaucoma or glaucoma progression (leading to optic nerve damage). One eye (study eye) contributed to the analysis. No formal statistical hypothesis testing was planned for the study.
Time frame: Up to Month 12 PostOperative
A device related adverse event (AE) was any AE that was considered to be possibly, probably, or definitely related to the device in the opinion of the investigator. Reported categorically as intraoperative (start date on the date of surgery) and postoperative (start date after surgery). One eye (study eye) contributed to the analysis. No formal statistical hypothesis testing was planned for the study.
Time frame: Baseline (Day -1), Month 12 PostOperative
IOP (fluid pressure inside the eye) was measured by Goldmann applanation tonometry. A higher IOP can be a greater risk for developing glaucoma or glaucoma progression (leading to optic nerve damage). A higher negative change indicates improvement. One eye (study eye) contributed to the analysis. No formal statistical hypothesis testing was planned for the study.
Time frame: Month 12 PostOperative
The use of ocular hypotensive medications was assessed in subjects with at least one IOP-lowering medication at 12 Months. One eye (study eye) contributed to the analysis. No formal statistical hypothesis testing was planned for the study.
Time frame: Screening (Day -2), Month 12 PostOperative
The number of IOP lowering medications in subjects at 12 months was compared to medicated baseline. A higher negative change indicates improvement. One eye (study eye) contributed to the analysis. No formal statistical hypothesis testing was planned for the study.
Transcend Medical, Inc.
Industry
Randomized, Prospective Clinical Evaluation of the Safety and Effectiveness of Visco-Assisted CyPass® Implantation in Patients With Open Angle Glaucoma
Acronym: ViscoPass
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07082816
Eye Diseases, Glaucoma
Dothan, Alabama, United States
View Trial DetailsNCT06851546
Eye Diseases, Glaucoma
Rochester, Minnesota, United States
View Trial DetailsNCT04060758
Eye Diseases, Glaucoma
Castle Hill, New South Wales, Australia
View Trial DetailsNCT06441643
Eye Diseases, Glaucoma
Garden Grove, California, United States
View Trial Details