DaVita Clinical Research
Minneapolis, Minnesota, 55404, United States
NCT Number: NCT05125848
The study is a prospective, single-arm, non-randomized, non-blinded, non-controlled, non-significant risk, single center study enrolling up to 20 subjects consented to undergo a hemodialysis session as a part of their standard prescribed treatment plan. Subjects will consent to undergo non-invasive monitoring with the CM-1500 during three (3) separate sequential hemodialysis sessions.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Minneapolis, Minnesota, 55404, United States
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
The CM-1500 is a U.S. FDA cleared non-invasive monitoring device that simultaneously monitors five (5) parameters of a patient's body. A combination of these parameters is represented by a single number known as the Relative Index value. This value is indicative of relative changes in fluid volume.
Time frame: Duration of post-hemodialysis recovery period (10-minutes)
The primary objective is to characterize the average CM-1500 Relative Index (RI) following a hemodialysis procedure. The RI is an investigational value which utilizes proprietary algorithms to combine the changes of multiple measured parameters (utilizing a weighted summation of percent change values) which are indicative of relative changes in fluid volume in adult patients into a single value. The RI is a unitless value with no set minimum or maximum, where 100 is a patient's baseline. Based on the nature of the RI itself, a direct interpretation of a positive or negative outcome cannot be derived from the absolute value, instead it could be used to monitor trending of a patient's parameters relative to their baseline. The average RI after dialysis procedure was calculated by averaging all measured RI values for all subject sessions (3 sessions per subject, totaling 45 sessions) during the 10-min post-hemodialysis recovery period.
Time frame: Duration of standard dialysis procedure (Range: 131 to 241 minutes)
The secondary objective is to characterize intrasubject variability in RI changes across 3 hemodialysis sessions. Cohort intrasubject variability was calculated by averaging individual subject standard deviations across enrollments. Variability for each subject is calculated by finding the RI mean and standard deviation for all RI values (1 per sec) during all 3 monitoring sessions. The RI is an investigational value which utilizes proprietary algorithms to combine the changes of multiple measured parameters (utilizing a weighted summation of percent change values) which are indicative of relative changes in fluid volume in adult patients into a single value. The RI is a unitless value with no set min. or max. where 100 is a patient's baseline. Based on the nature of the RI itself, a direct interpretation of a positive or negative outcome cannot be derived from the absolute value, instead it could be used to monitor trending of a patient's parameters relative to their baseline.
Time frame: Duration of standard dialysis procedure (Range: 131 to 241 minutes)
The secondary objective is to characterize intersubject variability in RI changes across 3 hemodialysis sessions. Intersubject variability was calculated by finding the mean and standard deviation of the variability (standard deviation) from the mean RI values (1 value per sec) for each hemodialysis session monitoring period (3 sessions x 15 subjects = 45 individual monitoring sessions). The RI is an investigational value which utilizes proprietary algorithms to combine the changes of multiple measured parameters (utilizing a weighted summation of percent change values) which are indicative of relative changes in fluid volume in adult patients into a single value. The RI is a unitless value with no set min. or max., where 100 is a patient's baseline. Based on the nature of the RI itself, a direct interpretation of a positive or negative outcome cannot be derived from the absolute value, instead it could be used to monitor trending of a patient's parameters relative to their baseline.
Zynex Monitoring Solutions
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05705115
Fluid Loss, Hemodynamic Instability
Oslo, Norway
View Trial DetailsNCT05070819
Cardiac Disease, Cardiac Output, High
Moscow, Russia
View Trial DetailsNCT05980013
Blood Loss, Fluid Loss
Denver, Colorado, United States
View Trial DetailsNCT05012462
Fluid Loss
Denver, Colorado, United States
View Trial Details