Skip to main content
OpenTrials
Completed

NCT Number: NCT05056870

Clinical Evaluation of Spherical Soft Contact Lenses, Toric Soft Contact Lenses and Spectacles in Low Astigmats

This will be a 5-visit, randomized, partially single-masked, bilateral wear, dispensing, 2-treatment × 2-period crossover study with spectacle-wear washout and wash-in periods.

Completed

Looking for future studies?

Notify Me

Key information

Conditions

Age range

18 year–39 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Eyecenter Optometric, Rocklin, California, United States

Loading trial locations.

Who can participate

Healthy volunteers accepted: Yes

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Potential subjects must satisfy of all the following criteria to be enrolled in the study.
  • Read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form.
  • Appear able and willing to adhere to the instructions set forth in this clinical protocol.
  • Be between 18 and 39 (inclusive) years of age at the time of screening.
  • By self-report, habitually wear soft contact lenses (sphere or toric) in both eyes in a daily reusable or daily disposable wear modality (i.e. not extended wear modality). Habitual wear is defined as a minimum of 6 hours of wear per day, for a minimum of 2 days per week during the past 4 weeks.
  • Possess a wearable pair of spectacles that provide correction for distance vision.
  • In both eyes, have magnitude of the cylinder component of their vertex-corrected distance refraction greater than or equal to 0.625 DC and less than 1.625 DC.
  • In both eyes, have the mean sphere of their vertex-corrected distance refraction minus half of the indicated contact lens label cylinder power be between -0.875 to -4.625 DS (inclusive).
  • For each eye, have the cylinder axis of their distance refraction between 165° and 15° (i.e., 180±15°, inclusive) or between 75° and 105° (i.e., 90±15°, inclusive).
  • For both eyes, have the sphere power of their habitual spectacles within ±0.50 Diopters Sphere (DS) (inclusive) of the sphere power of their current subjective refraction.
  • For both eyes, have the cylinder power of their habitual spectacles within ±0.50 Diopters Cylinder (DC) (inclusive) of the cylinder power of their current subjective refraction.
  • For both eyes, have the cylinder axis of their habitual spectacles within ±20° (inclusive) of the cylinder axis of their current subjective refraction.
  • Achieve monocular VA of 20/30 or better with their habitual spectacles in both eyes.

Exclusion criteria

  • Potential subjects who meet any of the following criteria will be excluded from participating in the study:
  • Be currently pregnant or lactating.
  • Be diabetic.
  • Be currently using any ocular medications or have any ocular infection of any type.
  • By self-report, have any ocular or systemic disease, allergies, infection, or use of medication that might contraindicate or interfere with contact lens wear, or otherwise compromise study endpoints, including infectious disease (e.g., hepatitis, tuberculosis), contagious immunosuppressive disease (e.g., Human Immunodeficiency Virus [HIV]), autoimmune disease (e.g. rheumatoid arthritis, Sjögren's syndrome), or history of serious mental illness or seizures. See section 9.1 for additional details regarding excluded systemic medications.
  • Have habitually worn rigid gas permeable (RGP) lenses, orthokeratology lenses, or hybrid lenses (e.g. SynergEyes, SoftPerm) within the past 6 months.
  • Be currently wearing monovision or multifocal contact lenses.
  • Be currently wearing lenses in an extended wear modality.
  • Have a history of strabismus or amblyopia.
  • Be an employee (e.g., Investigator, Coordinator, Technician) or immediate family member of an employee (including partner, child, parent, grandparent, grandchild or sibling of the employee or their spouse) of the clinical site.
  • Have participated in a contact lens or lens care product clinical trial within 7 days prior to study enrollment.
  • Have clinically significant (grade 3 or higher on the FDA grading scale) slit lamp findings (e.g., corneal edema, neovascularization or staining, tarsal abnormalities or bulbar injection) or other corneal or ocular disease or abnormalities that contraindicate contact lens wear or may otherwise compromise study endpoints (including entropion, ectropion, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, moderate or above corneal distortion, herpetic keratitis).
  • Have fluctuations in vision due to clinically significant dry eye or other ocular conditions.
  • Have had or have planned (within the study period) any ocular or intraocular surgery (e.g., radial keratotomy, PRK, LASIK, iridotomy, retinal laser photocoagulation, etc.).

Treatment and study plan

ACUVUE Oasys 1-Day with HydraLuxe Technology for Astigmatism

Device

TEST

ACUVUE Oasys 1-Day with HydraLuxe Technology

Device

CONTROL

Primary outcomes

  1. High Luminance High Contrast Monocular Visual Acuity (LogMAR)

    Time frame: 1-Week Follow-up

    Visual Acuity was collected for each subject eye at distance (4 meter) using a Logarithm of Minimal Angle of Resolution (logMAR) visual acuity scale. This was evaluated under high luminance and high contrast conditions (HLHC) at 4 meters from Early Treatment Diabetic Retinopathy Study (ETDRS) charts at the 1-week follow-up visit. A value of 0.0 logMAR is equivalent to 20/20 Snellen Visual Acuity. Lower values of visual acuity indicate better vision. The average logMAR Visual Acuity was reported for each lens type.

Secondary outcomes

  1. CLUE Vision Score

    Time frame: 1-Week Follow-up

    CLUE Vision Score was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120. The average CLUE vision score for each lens type was reported.

  2. High Luminance High Contrast Monocular Visual Acuity (LogMAR)

    Time frame: 1-Week Follow-up

    Visual Acuity was collected for each subject eye at distance (4 meter) using a Logarithm of Minimal Angle of Resolution (logMAR) visual acuity scale. This was evaluated under high luminance and high contrast conditions (HLHC) at 4 meters from Early Treatment Diabetic Retinopathy Study (ETDRS) charts at the 1-week follow-up visit. A value of 0.0 logMAR is equivalent to 20/20 Snellen Visual Acuity. Lower values of visual acuity indicate better vision. The average logMAR Visual Acuity was reported for each lens type. Data summaries for the Control lens are reported for the first primary measure outcome.

  3. Subjective Contact Lens Preference

    Time frame: 1-Week Follow-up

Sponsors and collaborators

Lead sponsor

Johnson & Johnson Vision Care, Inc.

Industry

Registry information

Important dates

Study start
2021
Primary completion
2022
Study completion
2022
First posted
Sep 27, 2021
Registry last updated
Apr 27, 2023

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.