ACUVUE® OASYS 1-DAY
Devicesenofilcon A contact lenses made with a novel manufacturing technology
Other names: TEST
NCT Number: NCT04531241
This study is a multi-site, randomized, double-masked, 2×2 crossover design, 1-week dispensing study. Subjects will wear bilaterally both Test and Control lenses in a random order for 1-week each as a daily disposable modality with a wash-out period of 1 week between the wearing periods.
Looking for future studies?
Notify Me18 year–70 year
All sexes
Interventional
Not applicable
Vue Optical Boutique, Jacksonville, Florida, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
senofilcon A contact lenses made with a novel manufacturing technology
Other names: TEST
Time frame: 1-Week Follow-up
Overall comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: 1-Week Follow-up
Overall vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
Time frame: 1-Week Follow-up
Visual performance was calculated as monocular contact lens-corrected distance visual acuity using a logMAR visual acuity scale. This was evaluated under both high luminance/low contrast conditions and low luminance/high contrast conditions at 4 meters from Early Treatment Diabetic Retinopathy Study (ETDRS) charts. The room illuminance was required to be between 7.3 and 7.9 EV (394-597 lux). For high illumination, the room was required to be >400 lux with low contrast charts. For low illumination, the room was required to be <2.5 lux. Letter-by-letter results calculated the visual performance score for each chart read. logMAR scores closer to zero, or below zero, indicate a better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.
Time frame: 1-Week Follow-up
Average daily wear time was calculated as the number of hours between subjects reported time of insertion and time of removal of the study lenses, on an average day, at 1-Week Follow up evaluation.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details