Skip to main content
OpenTrials
Completed

NCT Number: NCT05023746

Clinical Evaluation of Genetron Lung Cancer Panel in Non-small Cell Lung Cancer Patients

The purpose of this trail is to evaluate the performance of Genetron lung cancer panel in non-small cell lung cancer patients using semiconductor sequencing method.

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Observational

Primary location

Cancer Hospital Chinese Academy of Medical Sciences, Beijing, China

Loading trial locations.

About this study

This trial follows the principle of synchronous blinding. The enrolled cases are coded, and the enrolled samples are detected with Genetron lung cancer panel and comparison methods. The detection results are compared, and the samples that are inconsistent with the detection results of similar products on the market are reviewed by the the Sanger sequencing method, when the site detection results compared with Sanger sequencing method are inconsistent, Sanger's detection results are recognized. The safety and effectiveness of this panel are confirmed and evaluated. Meanwhile, the accuracy of this panel for the following drug companion diagnostic tests: EGFR gene 19 exon deletion and L858R point mutation in gefitinib tablets, erlotinib hydrochloride and icotinib hydrochloride tablets, T790M point mutation in methanesulfonate acid osimertinib tablets, ALK gene fusion in crizotinib capsules.

The results were determined independently according to the cutoff values or interpretation requirements provided by each method, and relevant statistics were used to evaluate clinical application performance of Genetron lung cancer panel.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Cancer samClinically diagnosed as non-small cell lung samples (mainly lung adenocarcinoma and some lung squamous cell carcinoma, adenosquamous carcinoma, large cell carcinoma, etc.), and a small number of other cancer types are enrolled as interference samples.
  • Collect some samples of relevant medical information before and after the use of targeted drugs. This part of the samples should have relevant previous molecular diagnosis results.
  • Able to provide samples in time according to the requirements of the plan: samples for DNA/RNA extraction: 10 pieces of 10 µm thickness for each sample or 10 pieces of paraffin rolls. Samples for FISH experiment: 5 slices of 3-4µm thickness.
  • The pathological examination conforms to the types of tissue samples listed in the above table. The HE staining results show that the tumor content is not less than 50%, and the paraffin slice damage should be avoided.
  • The sample should have corresponding basic clinical information, including: patient visiting number/medical record number/specimen number, age, gender, pathological diagnosis result, molecular diagnosis result (if any).

Exclusion criteria

  • Those who do not meet any of the above conditions are excluded. Reason: The included non-small cell lung adenocarcinoma samples and normal samples should have statistical significance, and the conclusions obtained should be scientific and valid. The selection of subjects for this study, while excluding research-related influencing factors, has no adverse effect on the health of the subjects.

Treatment and study plan

Genetron lung cancer panel

Diagnostic Test

Follows the principle of synchronous blinding. The enrolled cases are coded, and the enrolled samples are detected with Genetron lung cancer panel and comparison methods. The detection results are compared, and the samples that are inconsistent with the detection results of similar products on the market are reviewed by the the Sanger sequencing method, when the site detection results compared with Sanger sequencing method are inconsistent, Sanger's detection results are recognized. The results were determined independently according to the cutoff values or interpretation requirements provided by each method, and relevant statistics were used to evaluate clinical application performance of Genetron lung cancer panel.

Primary outcomes

  1. Efficacy of Genetron Lung Cancer Panel

    Time frame: 2 months

    The main purpose of this study is: by evaluating the Genetron Lung Cancer Panel to compare the results of simultaneous detection with similar products on the market and the Sanger sequencing method, and to calculate the coincidence rate and consistency of the panel and the comparison method.

Sponsors and collaborators

Lead sponsor

Genetron Health

Industry

Collaborators

  • Cancer Institute and Hospital, Chinese Academy of Medical Sciences
  • Genetron Health (Beijing) Co., Ltd.
  • Henan Cancer Hospital
  • Second Affiliated Hospital, School of Medicine, Zhejiang University
  • The First Hospital of Jilin University

Registry information

Important dates

Study start
2018
Primary completion
2019
Study completion
2019
First posted
Aug 27, 2021
Registry last updated
Sep 1, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.