etafilcon A with ketotifen
Combination ProductEtafilcon A with ketotifen
NCT Number: NCT03388138
This clinical study is a randomized, double-masked, bilateral, controlled, two-arm parallel group, multi-site, 1-Week, 2-visit dispensing study. Subjects between the ages of 18-40 will be randomized into a placebo arm or an investigational K-Lens arm.
Looking for future studies?
Notify Me18 year–40 year
All sexes
Interventional
Phase 2
Vue Optical Boutique, Jacksonville, Florida, United States
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Etafilcon A with ketotifen
1-Day ACUVUE
Time frame: Baseline (Visit 1) and 1-week follow up (Visit 2)
Monocular contact lens-corrected distance visual acuity was assessed using a logMAR visual acuity scale. This was evaluated for each eye, under high luminance and high contrast conditions at 4 meters from ETDRS charts. Distance visual acuity was reported by lens type and visit.
Time frame: Baseline (Visit 1) and 1-week follow up (Visit 2)
Monocular contact lens-corrected distance visual acuity was assessed using a logMAR visual acuity scale. This was evaluated for each eye, under high luminance and high contrast conditions at 4 meters from ETDRS charts. Distance visual acuity was reported by lens type and visit.
Time frame: Up to 1-Week Follow-up
Slit lamp findings were assessed using a biomicroscope for each subject eye at all scheduled and unscheduled visits. Clinical significant slit lamp findings are defined as Grade 3 or Grade 4. (Grade 0=None, Grade 1=Trace, Grade 2=Mild, Grade 3=Moderate and Grade 4= Severe). The data was dichotomized as 1=Grade 3 or Grade 4 and 0, otherwise. The number of eyes with clinically significant slit lamp findings for each lens type was reported.
Time frame: Up to 1-Week Follow-up
Lens fit was assessed for each subject and eye using a biomicroscope. Unacceptable lens fit was assessed at all scheduled and unscheduled visits. A subject was deemed to have an unacceptable lens fitting if they met any of the following criteria: (1) Limbal exposure at primary gaze with extreme eye movement, (2) edge lift, (3) excessive movement in primary up gaze, (4) insufficient movement in all three of the following conditions: primary gaze, up gaze and push up test. The number of eyes with unacceptable lens fitting was reported for each lens type.
Johnson & Johnson Vision Care, Inc.
Industry
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07174596
Visual Acuity
Roswell, Georgia, United States
View Trial DetailsNCT07076160
Eye Diseases, Presbyopia
Jacksonville, Florida, United States
View Trial DetailsNCT06864858
Visual Acuity
Maitland, Florida, United States
View Trial DetailsNCT07443215
Visual Acuity
Jacksonville, Florida, United States
View Trial Details