Skip to main content
OpenTrials
Completed

NCT Number: NCT03018392

Clinical and Radiological Evaluation of Patients With DDD Following TLIF With 3-D Printed Titanium Cage

The purpose of this study is to evaluate the fusion rate and clinical outcomes at 1 year of 20 patients with degenerative disc disease who undergo a Transforaminal Lumbar Interbody Fusion (TLIF) with the Stryker Tritanium Spinal System. This is an on-label, post-market outcomes study to build on the body of long-term evidence for the device.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Subject has one or more of the following diagnoses: degenerative disc disease (DDD) at one level or two contiguous levels from L2 to S1, and may also include up to Grade I spondylolisthesis at the involved level(s); degenerative scoliosis for which the Tritanium PL cage will be used as an adjunct to fusion
  • Skeletally mature and ≥ 18 years old at time of enrollment
  • Completed at least 6 months of non-operative therapy prior to surgery
  • Willing and able to sign a study specific consent and comply with the requirements of the protocol including follow up visits and imaging.

Exclusion criteria

  • 2 levels requiring surgical intervention
  • Non-degenerative pathology including tumor, trauma, post-laminectomy kyphosis
  • Psudeoarthrosis at the index level
  • Previous fusion at the levels to be treated or at adjacent level
  • Any abnormality present which affects the normal process of bone remodeling including, but not limited to, severe osteoporosis involving the spine, bone absorption, osteopenia, primary or metastatic tumors involving the spine, active infection at the site or certain metabolic disorders affecting osteogenesis.
  • History of osteoporotic fracture
  • History of an endocrine or metabolic disorder known to affect bone and mineral metabolism
  • Inadequate tissue coverage over the operative site or taking medications that may interfere with bony/soft tissue healing including chronic steroid use
  • Known allergy to titanium or cobalt chrome or may be sensitive to materials
  • Rheumatoid arthritis or other autoimmune disease or a systemic disorder such as HIV, active hepatitis B or C or fibromyalgia
  • Lumbar kyphosis- lumbar lordosis < 20°
  • Degenerative scoliosis >20° OR any other pathology scoliosis (idiopathic, congenital, posttraumatic, iatrogenic)
  • Active systemic infection or infection at the operative site
  • Marked local inflammation
  • Any open wounds
  • Pregnant, or intends to become pregnant during the study
  • Current smokers
  • Subject is class 3 obese (BMI >40) or overweight and can produce loads on the spinal system which can lead to failure of the fixation of the device or to failure of the device itself
  • Any mental or neuromuscular disorder which would create an unacceptable risk of fixation failure or complications in postoperative care
  • Any neuromuscular deficit which places an unsafe load level on the device during the healing period
  • Any other medical or surgical condition which would preclude the potential benefit of spinal implant surgery, such as the presence of tumors, congenital abnormalities, elevation of sedimentation rate unexplained by other diseases, elevation of white blood cell count (WBC), or marked left shift in the WBC differential count.
  • Any condition of senility, mental illness, or substance abuse.
  • Involved in current spinal litigation that may interfere or influence patient self-assessment of function and pain
  • Physical or mental condition that may interfere or influence patient self-assessment of function and pain.
  • Incarcerated at the time of study enrollment

Treatment and study plan

Stryker Tritanium Spinal System

Device

open transforaminal lumbar interbody fusion (TLIF) utilizing the Stryker Tritanium cages with pedicle screw fixation according to instructions for use and package labeling for on-label indications

Primary outcomes

  1. Fusion Rate

    Time frame: 1 year

    Fusion status at 1 year post-operatively was graded as - fused (best outcome), progressing, or pseudoarthrosis (failed fusion)

Sponsors and collaborators

Lead sponsor

Bone and Joint Clinic of Baton Rouge

Other

Registry information

Official study title

Fusion Rate and Clinical Outcomes Following 1 or 2 Level Open Transforaminal Lumbar Interbody Fusion for Degenerative Disc Disease With Novel 3-D Printed Titanium Cages With Pedicle Screw Fixation

Important dates

Study start
2017
Primary completion
2020
Study completion
2020
First posted
Jan 12, 2017
Registry last updated
Sep 7, 2022

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.