Cairo University
Giza, Egypt
Location status: Recruiting
NCT Number: NCT06599112
This study aims to compare the implant stability values following implant placement via Osteotomes and via Osseodensification using Densah Burs versus implant placement using conventional drilling technique in patients with upper posterior partially edentulous ridges as well as evaluating the crestal bone loss around temporary restorations following the three compared drilling techniques.
Interested in participating?
Request Info25 year–70 year
All sexes
Interventional
Not applicable
Giza, Egypt
Location status: Recruiting
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Series of drilling burs inserted in the osteotomy with special design that have a large negative rake angle flute, a cutting chisel edge and a tapered shank, so as they enter deeper into the osteotomy and they have a progressively increasing diameter that controls the expansion process. These burs are used with a standard surgical engine and can densify bone by rotating in the noncutting direction (counterclockwise at 800-1,200 rotations per minute) or drill bone by rotating in the cutting direction (clockwise at 800-1,200 rotations per minute) with an in and out movement together with copious saline irrigation and increasing bone plasticity and ability to expand under rate dependent stress.
The osteotomes kit are a series of tools that first designed by Summers in 1994. The concept was to maintain the existing bone by compressing trabecular bone laterally and apically with minimal trauma to improve the bone density. The condensed bone in this way will have to put in act a double repairing mechanism, from one side represented by the normal processes of osteointegration and on the other side from the processes of the reparation post fracture like that depends on BMU (bone modelling units) which create new spaces for the new vessels and afterwards filling all the gaps between the bone and the implant.
The implant drilling kit provided by the manufacturer will be used for the implant placement, using the pilot drill followed by consequent drills according to the size of the osteotomy needed.
Time frame: Will take place at same day,1,2,3,4,6,8 ,12and 16 weeks postoperatively.
ISQ units. (Implant Stability Quotient)
Time frame: Will be evaluated to determine the initial crestal bone level at day of the surgery as well at 12 and 48 weeks postoperatively.
Millimeters in standardized periapical radiograph
Time frame: Same day of surgery as well as 1 week postoperatively.
Visual Analogue Scale (VAS) on a scale of 0 to 10 where (0) is no pain and (10) is the maximum pain.
Time frame: Same day f surgery as well as 1 and 2 weeks postoperatively.
Questionnaire (3 yes or no questions)
Time frame: Same day of surgery (intraoperatively)
Minutes using stopwatch.
Time frame: Same day of surgery as well as 1 week postoperatively.
Number of analgesic tablets.
Contact information is provided by the study sponsor or research team.
Cairo University
Other
Clinical and Radiographic Evaluation of Implant Stability in Healed Maxillary Posterior Sites Comparing Osteotome, Osseodensification and Conventional Drilling Implant Placement Techniques: A Randomized Clinical Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07337538
Implant Stability, Tietz syndrome
Baghdad, Baghdad Governorate, Iraq
View Trial DetailsNCT06711744
Bone Healing, Implant Stability
Rome, RM, Italy
View Trial DetailsNCT06516263
Dental Implant, Implant Stability
Dublin, Ireland
View Trial DetailsNCT07557836
Implant Stability, Partially Edentulous Patients
Lucknow, Uttar Pradesh, India
View Trial Details