Sample collection
Other- Optional nasal specimen(s)
- Blood collection
NCT Number: NCT04403880
The purpose of this study is to learn more about infection with and recovery from the virus called severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Some people know this virus by the name "coronavirus." It can cause the disease called COVID-19.
The information gained from the study will be used to help develop better tests for SARS-CoV-2 infection and COVID-19 disease and may help in developing future vaccines and treatments by allowing researchers to determine the difference between the body's immune response to natural SARS-CoV-2 infection and immunization with a SARS-CoV-2 vaccine.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Malawi CRS, Lilongwe, Malawi
This study aims to characterize the SARS-CoV-2-specific immunity in convalescent individuals.
The observational cohort study will include 3 groups, as described in the table below.
Participants will complete a minimum of one visit (1-8 weeks post resolution of COVID-19 OR 2-10 weeks post most recent positive SARS-CoV-2 test, if asymptomatic) and optional visits approximately 2 months, 4 months, and 1 year later. Participants diagnosed with SARS-CoV-2 infection at an optional follow-up visit may be contacted more frequently. Additional follow up visit(s) may be added over time in response to evolving information regarding SARS-CoV-2 infection and COVID-19.
Study visits may include physical examinations, medical history, questionnaires, pregnancy tests (for participants assigned female at birth), blood draws, optional nasal samples, and optional HIV testing.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3, overall and by region and enrollment group
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3, overall and by region and enrollment group
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarizedSARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarizedSARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and enrollment group among America Cohort (USA and Peru only)
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2,3,4, overall and by region and enrollment group among America Cohort (USA and Peru only)
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and enrollment group among Africa Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and enrollment group among Africa Cohort
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by antibody-dependent cellular cytotoxicity assay (ADCC) at Visit 1, overall and by region and enrollment group among America Cohort (USA and Peru only)
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by antibody-dependent cellular cytotoxicity assay (ADCC) Visit 1, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Rate by flow cytometry at Visit 1 , overall and by region and enrollment group among America Cohort (USA and Peru only)
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and enrollment group among America Cohort positive responders (USA and Peru)
Time frame: Measured at Months 0.
SARS-CoV-2-specific B cell responses and B cell phenotypic data was identified and characterized using fluorescently-labelled recombinant Env proteins (S6P and RBD) in combination with a flow cytometry antibody panel on all available samples from the enrollment visit (V1). There is no positivity call for B cell phenotypic data. The magnitude is B cell subset frequency.
The table summarized SARS-CoV-2-specific Memory B Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and enrollment group among America Cohort (USA and Peru only)
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3 , overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and COVID-19 severity
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2,3,4, overall and by region and COVID-19 severity among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and COVID-19 severity
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and COVID-19 severity among Africa Cohort
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by antibody-dependent cellular cytotoxicity assay (ADCC) at Visit 1, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by antibody-dependent cellular cytotoxicity assay (ADCC) Visit 1, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Rate by flow cytometry at Visit 1, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and COVID-19 severity among America Cohort
Time frame: Measured at Months 0
SARS-CoV-2-specific B cell responses and B cell phenotypic data was identified and characterized using fluorescently-labelled recombinant Env proteins (S6P and RBD) in combination with a flow cytometry antibody panel on all available samples from the enrollment visit (V1). The sample will be included in the analysis only if the number of IgD- B cells is equal or greater than 1000 for that sample.
The table summarized SARS-CoV-2-specific Memory B Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and COVID-19 severity among America Cohort (USA and Peru)
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by BAMA IgG1 at Visit 1, 2, 3, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2,3, 4, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and days since SARS-CoV-2 diagnosis group among Africa Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and days since SARS-CoV-2 diagnosis group among Africa Cohort
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by antibody-dependent cellular cytotoxicity assay (ADCC) at Visit 1, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort (USA and Peru)
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by antibody-dependent cellular cytotoxicity assay (ADCC) Visit 1, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Rate by flow cytometry at Visit 1, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and days since SARS-CoV-2 diagnosis group among America Cohort
Time frame: Measured at Months 0
SARS-CoV-2-specific B cell responses and B cell phenotypic data was identified and characterized using fluorescently-labelled recombinant Env proteins (S6P and RBD) in combination with a flow cytometry antibody panel on all available samples from the enrollment visit (V1). The sample will be included in the analysis only if the number of IgD- B cells is equal or greater than 1000 for that sample.
The table summarized SARS-CoV-2-specific Memory B Cell Response Magnitude (B Cell) by Region and Days Since SARS-CoV-2 Diagnosis Group among America Cohort
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3 , overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2, 4
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG1) at Visit 1, 2, 3, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgG3) at Visit 1, 2, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgA) at Visit 1, 2, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2,3,4, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and comorbidity group among Africa Cohort
Time frame: Measured at Months 0, 2, 4, 12
Neutralizing antibodies against SARS coronaviruses are measured in 293T/ACE2 cells for all HIV negative samples. MPI (maximum percent inhibition) is also measured. Positivity calls are an ID50/ID80 (50% and 80% inhibitory dose) value either >20 (the lower limit of detection (LLOD) of the assay) or MPI is between 10%-50%. The neutralizing antibody ID50/ID80 of all HIV positive samples are measured by a different assay, VSV pseudovirus neutralization assay. Positivity calls are based on whether or not any neutralization is observed through entire titration (starting dilution 1:20) with MPI between 10%-50%. For the positive calls but the neutralization does not reach 50% or 80%, ID50/ID80 titer is first estimated by Prism.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by neutralizing antibody assay (NAb) at Visit 1, 2, 3, 4, overall and by region and comorbidity group among Africa Cohort
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Rate by antibody-dependent cellular cytotoxicity assay (ADCC) at Visit 1, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0
Antibody-dependent NK cell degranulation will be measured using ADCC assay at a dilution 1:500. Two readouts will be the background-subtracted % CD107A+ NK cells for the infected cells and the background-subtracted % CD107A+ NK cells for the transfected cells. The positive responses will be called if the values of background-subtracted % CD107A+ ≥ 4.07 and ≥5.27 for the infected and transfected cells, respectively. The cutoffs are determined by mean+2SD, respectively, from the SARS-CoV-2 negative controls. Percent CD107a+ NK Cells was the response magnitudes.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by antibody-dependent cellular cytotoxicity assay (ADCC) Visit 1, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Rate by flow cytometry at Visit 1, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0
Flow cytometry was used to examine SARS-CoV-2 specific CD4+ and CD8+ T-cell responses using an intracellular cytokine staining (ICS). Positive calls will be made using Fisher's exact positivity test for all the markers. The magnitudes are % T cells expressing IFN-g/IL-2.
The table summarized SARS-CoV-2-specific CD4+ and CD8+ T Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and Comorbidity Group among America Cohort
Time frame: Measured at Months 0
SARS-CoV-2-specific B cell responses and B cell phenotypic data was identified and characterized using fluorescently-labelled recombinant Env proteins (S6P and RBD) in combination with a flow cytometry antibody panel on all available samples from the enrollment visit (V1). The sample will be included in the analysis only if the number of IgD- B cells is equal or greater than 1000 for that sample.
The table summarized SARS-CoV-2-specific Memory B Cell Response Magnitude by flow cytometry at Visit 1, overall and by region and comorbidity group among America Cohort
Time frame: Measured at Months 0
SARS-CoV-2-specific Infection Presentation, Including Clinical Course, Along With Demographics and Corresponding Medical History of Participants , overall and by region
Time frame: Measured at Months 0
SARS-CoV-2-specific Infection Presentation, Including Clinical Course, Along With Demographics and Corresponding Medical History of Participants , overall and by region
Time frame: Measured at Months 0, 2, 5
BAMA assays was performed for samples from participants at Visit 1 (Month 0, baseline) and available samples at follow-up visits (Month 2, 4). Serum SARS-CoV-2-specific IgA, IgG1, IgG3 responses (dilution 1:50) to SARS-CoV-2 antigens were measured on a Bio-Plex instrument (Bio-Rad). The Bioplex software provides 2 readouts: a background-subtracted mean fluorescence intensity (MFI), where background refers to a plate level control (i.e., a blank well run on each plate), and a concentration based on a standard curve. Positive responses at each visit will be called if the MFI minus blank values are ≥ isotype, antigen, and dilution-specific cutoff (will be provided by the lab). MFIs minus blank (or net MFI) are used to summarize the magnitude at a given time-point.
The table summarized SARS-CoV-2-specific Antibody Binding Response Magnitude by binding antibody multiplex assay (BAMA IgA nasal sample) at Visit 1, 2, 3, overall and by region and enrollment group among America Cohort
Time frame: Measured at Months 0, Month 2, Month 4, Month 12
This outcome measures the detection rate of viral RNA in nasopharyngeal or nasal swab samples collected at Visits 1, 2, 3, 4 using RT-PCR. Participation was optional, and not all participants provided samples. Results presented in this table include only participants from the Africa cohort (South Africa and other African countries), whose samples were tested using the RT-RNA Fisher TaqPath assay and Americas cohort (Peru and the United States), samples were tested using the RT-RNA Panther assay.
HIV Vaccine Trials Network
Network
Characterizing SARS-CoV-2-specific Immunity in Convalescent Individuals
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07720596
COVID-19, Coronaviridae Infections
Prague, Czechia
View Trial DetailsNCT06743334
COVID-19, Coronaviridae Infections
Seoul, South Korea
View Trial DetailsNCT05876377
COVID-19, Chronic Disease
New York, United States
View Trial DetailsNCT05728970
COVID-19, Coronaviridae Infections
Garden Grove, California, United States
View Trial Details