cataract surgery
Procedurecataract surgery with phacoemulsification and implantation of multifocal posterior chamber intraocular lens
NCT Number: NCT03297086
The purpose of this study is to evaluate possible changes of angle kappa after multifocal intraocular lens implantation. Presumable influencing factors of postoperative visual axis shift (ie. biometric parameters of the eye) are investigated to determine the degree and direction of angle kappa alterations.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
The purpose of this study is to evaluate changes of angle kappa after multifocal intraocular lens implantation.
During cataract surgery Medicontur Bi-Flex 677MY IOL and Alcon Acrysof Restor SN6AD1 IOL are implanted. Optical biometry is carried out for IOL calculation and to measure axial length and angle kappa. Three months after surgery biometry is repeated, IOL position and angle kappa are measured using Scheimpflug-camera.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
cataract surgery with phacoemulsification and implantation of multifocal posterior chamber intraocular lens
Time frame: 3 months
Changes in magnitude and orientation of angle kappa (deviation between the visual and pupillary axis) are measured before and after cataract surgery with multifoocal intraocular lens implantation. During pre-and postoperative examination optical biometry is carried out using Lenstar LS 900. Optical biometer determines deviation between the visual and pupillary axis that represents angle kappa. Deviation of these axes can be defined by its magnitude and orientation. Location of the pupil centre relative to the visual axis - the reference axis - is determined by x- and y-offsets using trigonometrical analysis.
Time frame: 3 months
Biometry data (axial length, keratometry, lens thickness, anterior chamber depth) are measured preoperatively by Lenstar LS 900 optical biometer. Their effect on changes of angle kappa is determined using statistical analysis.
Time frame: 3 months
Three months after cataract surgery postoperative intraocular lens (IOL) position is determined using a rotating Scheimpflug-camera (Galilei G4). IOL decentration is obtained from the distance between the IOL centre and visual axis. The effect of possible IOL decentration on changes of angle kappa is determined using statistical analysis.
Semmelweis University
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05411341
Cataract, Eye Diseases
Alexandroupoli, Evros, Greece
View Trial DetailsNCT06460389
Cataract, Eye Diseases
Alexandroupoli, Evros, Greece
View Trial DetailsNCT07385014
Cataract, Eye Diseases
Hershey, Pennsylvania, United States
View Trial DetailsNCT05574270
Cataract, Eye Diseases
Makati City, Philippines
View Trial Details