NCT Number: NCT04724525
Astigmatism is a common refractive error resulting from a toric-surfaced cornea which using a toric soft contact lens could be one of the therapy options. Due to the numerous possible combinations between sphere powers, cylinder powers, and cylinder axes, manufacturers of disposable soft toric contact lenses limit their toric lens range, while still aiming to cater to the majority of astigmatic patients. Due to that reason, the possibility of astigmatism patients getting a different combination of power and axis with toric soft contact lenses sold on the market will be high due to SKU limitations. This research aims to ascertain the impact of altering cylinder power and axis on visual quality and convenience in astigmatism participants using toric soft contact lens. The study was conducted at Kirana Ciptomangunkusumo Hospital, Jakarta, starting in April 2020. The study is a prospective, randomized, participant-masked, crossover clinical trial where the participants were tested for the following conditions on different days using full spherocylinder correction and under-correction by 0.25, 0.50, and 0.75 DC while maintaining spherical equivalence. Axis was also misaligned between -30° and +30°, in 10° steps. For each visit, the patient was examined visual acuity, contrast visual acuity using the Pelli-Robson, and assessed patient comfort using the VAS method.
Looking for future studies?
Notify Me20 year–35 year
All sexes
Interventional
Not applicable
Jakarta Pusat, Jakarta Special Capital Region, 10430, Indonesia
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
soft contact lens toric with different axis and power that use in human's eye
Time frame: when using a contact lens (0 day,7 days, 14 days)
Visual acuity was measured using a Snellen chart at a distance of 6 meters by the researcher (DA) at Refractive Poly
Time frame: when using a contact lens (0 day,7 days, 14 days)
Value obtained on examination of the Pelli Robson Chart in Poly Neurooftlamology. Examination conducted by researchers (DA).
Time frame: when using a contact lens (0 day,7 days, 14 days)
Values were obtained by the VAS method. Research subjects were asked to name a number from 1-10 (score 1 indicates poor clarity, 10 indicates good clarity) to assess visual clarity
Time frame: when using a contact lens (0 day,7 days, 14 days)
Values were obtained by the VAS method. The research subjects were asked to name a number from 1-10 (a score of 1 indicates dissatisfaction, 10 indicates very satisfied)
Indonesia University
Other
The Effect of Changes in Power and Cylinder Axis on Vision Quality, Satisfaction and Vision Acceptability of People With Mild-Medium Astigmatism With Toric Soft Contact Lenses (LKL)
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04703231
Eye Diseases, Macula Edema
Batman, Turkey (Türkiye)
View Trial DetailsNCT04985097
Blindness, Eye Diseases
Valladolid, Spain
View Trial DetailsNCT01244334
Cataract, Cataracts
Edgewood, Kentucky, United States
View Trial Details