Monitoring with contact lens sensor
DeviceMonitoring with contact lens sensor at 1-month pre-intervention visit
NCT Number: NCT06607705
The purpose of this study is to compare the IOP-related fluctuations using the CLS (contact lens sensor) Sensimed Triggerfish in glaucoma patients before and after glaucoma surgery with iStent inject W under physiological conditions and compare these results with a control group of glaucoma patients treated only with hypotensive medical treatment requiring cataract surgery.
Interested in participating?
Request Info18 year and older
All sexes
Interventional
Not applicable
Hospital Clínic de Barcelona, Barcelona, Spain
This is a prospective controlled pre-post intervention study conducted at a Hospital Clínic of Barcelona, a university hospital in Barcelona, Spain. This study will be adhered to the tenets of the Declaration of Helsinki. Informed patient consent and approval by the Institutional Review Board will be obtained prior to study commencement. Study duration is expected to be around 12 months, recruitment period would last between 6 to 8 months and study is expected to be finalized by Jun 2025.
The study will recruit consenting adults (over 18 years old) with unilateral or bilateral primary open-angle glaucoma (POAG) without previous eye surgery, treated with topical anti-glaucoma medications, who need glaucoma surgery with iStent inject W. The investigators will include patients with isolate iStent surgery and patients with combined cataract and iStent surgery. In cases of bilateral glaucoma, the two eyes of the same patient may be included consecutively.
One month prior to glaucoma surgery with iStent inject W, subjects will wear the CLS for 24 hours without changing the regimen of anti-glaucoma eye drops. The CLS will be placed on the subject's eye by an ophthalmologist in the clinic after a slit lamp examination and keratometry to determine the corneal curvature for selection of the appropriate CLS base curve. The subjects will then return home and carry on their routine activities (both indoor and outdoor), apart from showering or swimming (as the device cannot be in contact with water). Subjects will continue the same regimen of anti-glaucoma eye drops and slept in their habitual position at night. Each subject will carry a logbook to record sleeping and medication instillation times during the 24-hour period. After 24 hours, the subject will return to the clinic to have the contact lens removed followed by a slit lamp examination. The data recorded by the CLS will be uploaded into a computer database. Goldmann applanation tonometry (GAT) will be perform before and after each CLS wear by a single observer. At 1-month (n=9/44) and 3-month (n=44) post-glaucoma surgery with iStent implant, patients will wear the CLS in the same eye that received the first CLS recording. As before, the CLS will be removed 24 hours later. To extend the follow-up to 3 months after surgery will allow us to corroborate that the effects of the surgery on fluctuations of IOP for 24 hours are maintained over time. In the control group (n=10) , a first monitoring with CLS will be carried out one month before cataract surgery, and a second monitoring will be carried out 3 months after this cataract surgery, without us having introduced any changes in their hypotensive medical treatment.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
with unilateral or bilateral open-angle glaucoma (POAG) without previous eye surgery, treated with topical anti-glaucoma medications, who need glaucoma surgery with iStent inject W. The investigators will include patients with isolate iStent surgery and patients with combined cataract and iStent surgery. In cases of bilateral glaucoma, the two eyes of the same patient may be included consecutively.
For the control group only: Patients with topical hypotensive glaucoma treatment requiring cataract surgery.
Exclusion criteria
Monitoring with contact lens sensor at 1-month pre-intervention visit
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
The amplitude of the cosine curve is a parameter based on the cosine model fitted to the CLS data. The amplitude is the difference between the maximum and minimum values of the cosine-fit curve divided by 2. This is an overall estimate of the magnitude of signal oscillation during the tested period. The cosinor model represents the actual amplitude of IOP-related fluctuation over a 24- hour period and is most representative of IOP-related changes.
IOP-related fluctuations will be calculated based on the GAT IOP measured at baseline and at each visit during the study.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
CLS (Contact Lens Sensor) increase and decrease rates (change in CLS units/ change in time): maximum
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
CLS (Contact Lens Sensor) increase and decrease rates (change in CLS units/ change in time): minimum.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
CLS (Contact Lens Sensor) increase and decrease rates (change in CLS units/ change in time): median.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
CLS (Contact Lens Sensor) increase and decrease rates (change in CLS units/ change in time): mean.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
Calculation of sleep-to-wake slope.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
Calculation of wake-to-sleep slope.
Control group will not be monitored in the 1-month visit.
Time frame: 24 hours during 1-month pre-intervention visit, 24 hours during 1-month post-intervention visit and 24 hours during 3-month post-intervention visit
Number of peaks: over 24 hours, inferior to 30 minutes, superior to 90mVeq.
Control group will not be monitored in the 1-month visit.
Contact information is provided by the study sponsor or research team.
Fundacio Privada Mon Clinic Barcelona
Other
Fluctuations of the Intraocular Pressure in Surgically Treated Glaucoma Patients with IStent Inject W by a Contact Lens Sensor
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07303257
Closed-Angle Glaucoma, Eye Diseases
Lyon, France
View Trial DetailsNCT05449041
Cataract, Eye Diseases
Skjetten, Akershus, Norway
View Trial DetailsNCT05895617
Corneal Diseases, Eye Diseases
Reading, Berkshire, United Kingdom
View Trial DetailsNCT03996200
Eye Diseases, Glaucoma
Barranquilla, Colombia
View Trial Details