CGM
OtherThis study seeks to assess CGM accuracy and develop prediction models for hypoglycemia detection and no intervention is therefore applied.
NCT Number: NCT03842683
Use of devices for continuous monitoring of the blood sugar is valuable for people with diabetes to understand their disease and to help prevent low blood sugar. Furthermore, continuous monitoring should be used in drug development to evaluate efficacy and safety. However, the devices have been criticised for being too inaccurate. This investigation sought to reveal the inaccuracies of current devices and to assess the subsequent usability related to the mentioned use cases.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
The following study is an exploratory investigation of continuous glucose monitoring based on data from a completed Novo Nordisk A/S clinical trial. Please refer to ClinicalTrials.gov Identifier: NCT02825251.
Continuous Glucose Monitoring (CGM) provides an interstitial glucose reading every 5 minutes and is thus a powerful and important tool to identify glycaemic variability in people with diabetes. CGM is valuable for people with diabetes to understand their glucose metabolism and it has the potential to be used for detection and prediction of glycaemic excursions, such as, the potentially fatal and inevitable events of hypoglycaemia, or even as a component in the holy grail of diabetes technology; the artificial pancreas.
However, CGM has been criticised for being inaccurate and unreliable, amongst others, due to the physiological and a device-related delay between plasma glucose (PG) and interstitial glucose (IG). Nevertheless, CGM keeps on being popular and in February 2017 an international consensus was established at the Advanced Technologies & Treatments for Diabetes (ATTD) congress that even considers CGM data as a valuable and meaningful end point to be used in clinical trials of new drugs and devices for diabetes treatment where accuracy is of high importance.
The above mentioned use cases entail that the CGM data are accurate. Therefore, the first part of this research proposal is to investigate whether the newest state-of-the-art CGM devices used in Novo Nordisk trials are in fact accurate. Based on these results, it is investigated to which degree glycaemic variability can be revealed.
To investigate the accuracy of CGM, mean absolute relative difference (MARD) will be calculated and presented and the impact of the delay assessed by time shifting CGM measurements. Furthermore, correlation analyses, between for example, PG and first derivative of IG, will be performed to try to understand when CGM devices tend to measure inaccurate. Lastly, machine learning and/or deep learning approaches will be utilised to reveal glycaemic patterns and to detect/predict outcomes, such as, hypoglycaemia.
Different glycaemic variability investigations will be undertaken:
Requested data are demographic, CGM, meal, dose and hypoglycaemia data from the following trial. The analyses are independent of treatment and therefore the treatment arm can be blinded.
Only the study team can determine whether someone qualifies for participation.
As copied from the original clinical trial ClinicalTrials.gov Identifier: NCT02825251
Inclusion criteria
Exclusion criteria
This study seeks to assess CGM accuracy and develop prediction models for hypoglycemia detection and no intervention is therefore applied.
Time frame: 16 weeks
Continuous glucose monitoring (CGM) measurements are delayed compared to blood glucose. The CGM signal is time-shifted -1 minute at a time and the mean absolute difference between CGM and blood glucose measurements are calculated at each step. The lowest mean absolute difference depicts the optimal time shift in minutes. The resultant mean absolute relative difference is provided as outcome.
Publication reference: https://doi.org/10.1177/1932296819848721
Time frame: 16 weeks
Area under the receiver operating characteristics curve (ROC-AUC) is a measure of the prediction capabilities of a prediction algorithm. Each point of the curve gives a sensitivity and a specificity of the prediction.
Publication reference: https://doi.org/10.1177/1932296819868727
Peter Vestergaard
Other
Are Todays Continuous Glucose Monitoring Precise and Can They be Used to Reveal and Reduce Glycaemic Variability?
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03529188
Autoimmune Diseases, Diabetes Mellitus
Brest, France
View Trial DetailsNCT02546401
Autoimmune Diseases, Diabetes Mellitus
Brest, France
View Trial DetailsNCT06529705
Autoimmune Diseases, Diabetes Mellitus
Montpellier, France
View Trial DetailsNCT06365255
Autoimmune Diseases, Diabetes Mellitus
Angers, France
View Trial Details