Duzce University Faculty of Medicine
Düzce, 81000, Turkey (Türkiye)
NCT Number: NCT05571683
Today, phacoemulsification has become the most commonly applied method in the treatment of cataract, which is considered as a public health problem. Since the eyelid margins can be a source for pathogens in phacoemulsification surgery draping after skin sterilization is applied to remove the eyelashes from the operation area. Since surgical drapes are airtight, carbon dioxide (CO2) accumulation occurs under the drape in patients under local anesthesia. During the operation, if the end tidal CO2 pressure value rises, this can lead to hyperventilation and tachycardia and also increase the intraocular pressure which is undesirable in eye surgery. In our study, in order to observe and compare undesirable conditions, regional tissue oxygenation saturation (rSO2) will be determined non-invasively with Transcutaneous Near Infrared Spectroscopy (NIRS) technology , which allows real-time monitoring. Changes in the partial pressure of carbon dioxide (PaCO2) are strongly vaso-active, resulting in changes in cerebral blood volume and hence intracranial pressure.
As the optic nerve sheath is an extension of the brain dura mater, the diameter of the sheath expands in case of increased intracranial pressure. Evaluation of the optic nerve sheath with ultrasound allows us to obtain information about intracranial pressure. For optic nerve sheath diameter, measurements above 5.0 mm in adult patients are generally considered as increased intracranial pressure.
COVID-19 is a global epidemic caused by SARS-CoV-2 that we are still fighting. Although it is a multisystemic disease, it is important in terms of its effects on pulmonary function and the continuity of pulmonary symptoms and findings after this disease has been overcome.
In our study, End-Tidal CO2 and cerebral oximetry (NIRS) values will be determined and compared between the groups that received 2lt/min and 4lt/min nasal oxygen support during cataract surgery performed using draping under local anesthesia in patients who had COVID-19, recovered and never had. It was aimed to evaluate and compare the values of optic nerve sheath diameter increase.
Looking for future studies?
Notify Me18 year–80 year
All sexes
Observational
Düzce, 81000, Turkey (Türkiye)
After the patients who meet the specified criteria are informed about the study, the volunteers who agreed to participate and signed informed consent will be included in the study.
After all volunteers are taken to the operation room, vascular access will be established, electrocardiography, pulse oximetry, non-invasive blood pressure, end-tidal carbon dioxide and cerebral oximetry (with the neck in the supine position in the neutral position and 2 probes placed on the forehead) are monitored without any medication (Figure 1). The optic nerve sheath diameter will be measured by the ultrasonography device in the inventory of the Department of Anesthesiology and Reanimation by the researchers, basal heart rate (CTA), peripheral oxygen saturation (SpO2), systolic (SBP) and diastolic blood pressure (DBP), end- Tidal carbon dioxide (ETCO2), cerebral oxygen saturation (SO) values will be recorded. All measurements except optic nerve sheath diameter will be recorded and repeated at 5 minute intervals throughout the operation. During this time, no drugs or invasive methods will be used.
During the operation, the volunteers in both groups will be randomly divided into 2 subgroups and 2L/min and 4 L/min nasal oxygen support will be provided. At the end of the operation, the ultrasonographic optic nerve sheath diameter measurement will be repeated immediately after the dressing is removed.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
40 patients (2 arms) will be supported with 2 l/min oxygen and the other 2 arms (40 patients) will be supported with 4 l/min oxygen under the surgical drapes.
Time frame: End tidal carbondioxide values will be measured continously during the operation and recorded in every 5 minutes from the draping to the end of the operation.
End tidal carbondioxide values will be measured continously during the operation with a capnograph device via nasal cannula non-invasively and recorded.
Time frame: Cerebral oxygenisation values will be measured continously during the operation and recorded in every 5 minutes from the draping to the end of the operation.
Cerebral oxygenisation values will be measured continously during the operation with a transcutaneous near infrared spectroscope device (NIRS) via a transcutaneous probe placed on the frontal bone non-invasively and recorded.
Time frame: 2 times, once before acceptance in the operation room, and secondly on the end of the operation before undraping.
The optic nerve sheath diameter will be measured ultrasonographically by the same experienced researcher before and on the end of the operation.
Duzce University
Other
Comparison of Cerebral Oxymeter and End Tidal Carbondioxide Values Under Surgical Drapes in Patients With and Without Past COVID-19 Infection Undergoing Cataract Operation
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03364972
Behavior, Cataract
London, United Kingdom
View Trial DetailsNCT02973880
Cataract, Cataract Extraction
Potsdam, Germany
View Trial DetailsNCT00366691
Cataract, Cataract Extraction
Charleston, South Carolina, United States
View Trial DetailsNCT00366587
Cataract Extraction
Charleston, South Carolina, United States
View Trial Details