Implantation of CEP Magna Ease Model 3300TFX
DeviceHeart Valve Surgery
Other names: CEP Magna Ease MOdel 3300TFX
NCT Number: NCT01171625
The purpose of the study is to demonstrate the long term safety and effectiveness of the Carpentier-Edwards PERIMOUNT Magna Ease Valves in patients undergoing aortic valve replacement with or without concomitant procedures requiring cardiopulmonary bypass.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Universitatslinik fur Chirurgie, Innsbruck, Austria
This is a prospective, single-arm, multi-center, interventional study to be conducted in the US and outside the US (OUS). This study will enroll a minimum of 225 patients implanted with the study valve in order to achieve 101 aortic valve replacement subjects each followed for a minimum of 8 years. The study will include male and female patients, 18 years or older, requiring replacement for a diseased, damaged or malfunctioning natural or prosthetic aortic valve. Patients will be followed and assessed after implant at discharge, 6 months, one year, and annually for a minimum of 8 years.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Heart Valve Surgery
Other names: CEP Magna Ease MOdel 3300TFX
Time frame: 31 days through 8 years post-implant
Long term safety performance will be evaluated by comparing the linearized yearly rates to the objective performance criteria (OPC) referenced in the Food and Drug Administration (FDA) 1994 Draft Heart Valve Guidance.
Expressed as the Number of late events divided by the total number of late patient years times 100. Late patient years are calculated from 31 days post-implant to the date of the last contact (follow up or adverse event).
Time frame: 8 years post-implant
The New York Heart Association (NYHA) functional classification system relates symptoms to everyday activities and the patient's quality of life.
Class I. No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, dyspnea (shortness of breath).
Class II. Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, dyspnea (shortness of breath).
Time frame: 8 Years post-implant
The New York Heart Association (NYHA) functional classification system relates symptoms to everyday activities and the patient's quality of life.
Class I. No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, dyspnea (shortness of breath).
Class II. Slight limitation of physical activity. Comfortable at rest. Ordinary physical activity results in fatigue, palpitation, dyspnea (shortness of breath).
Class III. Marked limitation of physical activity. Comfortable at rest. Less than ordinary activity causes fatigue, palpitation, or dyspnea.
Class IV. Unable to carry on any physical activity without discomfort. Symptoms of heart failure at rest. If any physical activity is undertaken, discomfort increases.
Time frame: Events occurring within 30 days of procedure
Number of early adverse events occurring within 30 days of procedure divided by the number of enrolled subjects times 100.
Time frame: Events occurring >= 31 days and up through 8 years post-implant
Number of late events divided by the total number of late patient years times 100. Late patient years are calculated from 31 days post-implant to the date of the last contact (follow up or adverse event).
Time frame: 1 Year, 2 Years, 3 Years, 4 Years, 5 Years, 6 Years, 7 Years, and 8 Years post-implant
Subject's freedom from Serious Adverse Events at > 30 days post-implant. Time to events were estimated by Kaplan-Meier method.
Time frame: 8 years post-implant
Peak systolic gradient is the maximum value measured of flow of blood through the aortic valve as measured in millimeters of mercury. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Mean systolic gradient is the average flow of blood through the aortic valve measured in millimeters of mercury. Mean gradient values depend on the size and type of valve. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Effective orifice area represents the cross-sectional area of the blood flow downstream of the aortic valve. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Effective orifice area index represents the minimal cross-sectional area of the blood flow downstream of the aortic valve divided by the person's body surface area. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Performance index is defined as the subject's effective orifice area (the cross-sectional area of the blood flow downstream of the aortic valve) divided by the subject's native orifice area. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
The amount of blood the heart pumps through the circulatory system in a minute. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Cardiac index is an assessment that divides the cardiac output from left ventricle in one minute by the person's body surface area (BSA), thus relating heart performance to the size of the individual. The data summary will be stratified by valve size.
Time frame: 8 years post-implant
Aortic valvular regurgitation occurs when the aortic valve in the heart does not close tightly allowing some of the blood that was pumped out of the heart to leak back into it. Aortic valvular regurgitation is evaluated by echocardiography over time. It is assessed on a scale from 0 to 4, where 0 represents no regurgitation and 4 represents severe regurgitation.
Time frame: 6 months and annually for 8 years post-implant
Laboratory analysis of White Blood Cell Count on blood drawn from subject; WBC fight infection.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of Red Blood Cell (RBC) Count on blood drawn from subjects; RBC carry oxygen.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of Hematocrit Percentage on blood drawn from subjects. Hematocrit is the proportion of red blood cells to the fluid component (plasma) in the blood.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of Hemoglobin Count on blood drawn from subjects. Hemoglobin is an oxygen-carrying protein in red blood cells.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of Platelet Count on blood drawn from subjects; platelets help with blood clotting.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of Serum Lactate Dehydrogenase on blood drawn from subjects; The lactate dehydrogenase (LDH) test looks for signs of damage to the body's tissues.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of haptoglobin on blood drawn from subjects; haptoglobin is a protein produced by the liver.
Time frame: 6 months and annually for 8 years post-implant
Laboratory Analysis of reticulocytes on blood drawn from subjects. Reticulocytes are newly produced immature red blood cells; a reticulocyte blood test measures the amount of these cells in the blood.
Time frame: Baseline and 6 Months Post-Implant
The EQ-5D is a standardized questionnaire that asks subjects to rate themselves (no problems, some problems, extreme problems) on mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. The scale ranges from a minimum of 0 and a maximum of 100 where zero is the 'worst state imaginable' and 100 is the 'best state imaginable'.
Edwards Lifesciences
Industry
Carpentier-Edwards PERIMOUNT Magna Ease Pericardial Bioprosthesis in the Aortic Position, Model 3300TFX
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT01651052
Aortic Valve Disease, Aortic Valve Disorder
Krakow, Poland
View Trial DetailsNCT02375282
Aortic Valve Disease, Aortic Valve Insufficiency
Springfield, Massachusetts, United States
View Trial DetailsNCT07476703
AORTIC VALVE DISEASES, Aneurysm
Stockholm, Sweden
View Trial DetailsNCT04464655
Aortic Stenosis, Subvalvular, Aortic Valve Disease
Montreal, Quebec, Canada
View Trial Details