Skip to main content
OpenTrials
Completed

NCT Number: NCT00600327

Carotid Artery Revascularization Using the Boston Scientific EPI Filter Wire EZ™ and the EndoTex™ NexStent™

The primary objective of this study is to demonstrate the safety of the NexStent for treatment of carotid artery lesions undergoing stenting with adjunctive use of the FilterWire distal embolic protection device. The rates will be compared to an Objective Performance Criterion (OPC) derived from historic data from high-risk patients undergoing surgical intervention with Carotid endarterectomy. Patients included in this study are those at higher risk for complications associated with CEA.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Interventional

Phase

Phase 3

Primary location

Favaloro Institute, Buenos Aires, Argentina

Loading trial locations.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • patient is greater than or equal to 18 years of age.
  • Anticipated patient life expectancy is of at least one year from the date of the index procedure.
  • Lesion is located in the common carotid artery (CCA) and/or the internal carotid artery (ICA) or the carotid bifurcation.
  • Target vessel is the only vessel being treated at this intervention and the lesion is less than or equal to 30 mm and can be treated with a single stent.
  • Vessel to be treated is between 4.0 mm and 9.0 mm in diameter.
  • Patient can be either symptomatic or asymptomatic; Symptomatic: Stenosis must be greater than or equal to 50% as determined by angiogram and the patient has a history of stroke, TIA and/or amaurosis fugax in the hemisphere supplied by the target vessel within 180 days of the procedure.
  • Patient can be either symptomatic or asymptomatic; Asymptomatic: Stenosis must be greater than or equal to 60% as determined by angiogram without any neurological symptoms.
  • Distal vessel "landing zone" for placement of the FilterWire must be between 3.5 mm and 5.5 mm in diameter with visual angiographic recommendations as described in the IFU.
  • Female patients with no childbearing potential or a documented negative pregnancy test (urine or blood) within 10 days of the index procedure.
  • Patient (or their legal guardian) understands the nature of the procedure and has provided a signed informed consent using a form that has been reviewed and approved by the Investigational Review Board/Ethics Committee of the respective clinical site prior to the procedure. This will be obtained prior to participation in the study.
  • Patient is willing to comply with the protocol requirements and return to the treatment center for all required clinical evaluations
  • Patient must fulfill at least one of the following Class I: Unstable angina, LVEF less than 30%, CHF class III or class IV, dialysis dependent renal failure, severe COPD, requirement for staged CABG or valve replacement post carotid index procedure,Previous carotid endarterectomy with significant restenosis, total occlusion of the contralateral carotid artery, Previous radiation treatment to the neck or radical neck dissection, Target lesion is at or above the second vertebral body C2 or below the clavicle, Inability to extend the head due to cervical arthritis or other cervical disorders, Tracheostomy or tracheal stoma,Presence of laryngeal nerve palsy, Bilateral carotid artery stenosis as determined by angiography.
  • If a patient does not meet Class I criteria, a patient must meet two of the follwing class II criteria: Patient is greater than or equal to 75 years of age, Myocardial infarction within previous 6 weeks, Requires staged peripheral vascular surgery (i.e. abdominal aortic aneurysm repair) or other major surgery post carotid index procedure, Two or more proximal or major diseased coronary arteries with greater than or equal to 70% stenosis that have not or cannot be revascularized.

Exclusion criteria

  • Previously placed stent in target vessel.
  • Total occlusion of target vessel (ICA or CCA).
  • Angiographically visible thrombus.
  • Carotid string sign (a tiny, long segment of contrast in the true lumen of the artery, aneurysmal pouch formation, and the distal location of the arteriopathy) with poor visualization of the distal vessel.
  • Vertebrobasilar insufficiency symptoms only, without clearly identifiable symptoms referable to the targeted carotid artery.
  • Vessel anatomy precluding use of stent system or distal protection system.
  • Presence of carotid artery dissection.
  • Requirement for staged CABG, valve replacement or abdominal aortic aneurysm procedure 30 days before or after the index procedure.
  • Evidence of a major disabling stroke within the previous 30 days.
  • Patient has an evolving stroke or has experienced a major stroke (NIHSS score greater than or equal to 15) within 3 months.
  • History of intracranial hemorrhage within the past 12 months.
  • Any condition that precludes proper angiographic assessment or makes percutaneous arterial access unsafe, e.g. morbid obesity, history of chronic hypertension that is not controlled by medical therapy.
  • Contraindication to heparin, aspirin, clopidogrel (Plavix®), X-ray contrast or ticlopidine (Ticlid®)in cases of intolerance to clopidogrel.
  • History of liver failure with elevated prothrombin time.
  • History or current indication of bleeding diathesis or coagulopathy.
  • Hgb <8 gm/dl (unless on dialysis), platelet count < 50,000, WBC >15,000, INR > l.5 (irreversible) or heparin-associated thrombocytopenia.
  • Known cardiac sources of emboli not under treatment with anticoagulant therapy.
  • Atherosclerotic disease involving adjoining vessels precluding safe placement of the guiding catheter or sheath.
  • Planned treatment of non-target lesion within 30 days.
  • Other abnormal angiographic findings that indicate the patient is at risk of a stroke due to a problem other that the target lesion, such as: ipsilateral arterial stenosis greater in severity than the target lesion, cerebral aneurysm, or arteriovenous malformation (AVM) of the cerebral vasculature.
  • Dementia or confusion.
  • The patient is enrolled in another study protocol.
  • Patient may not participate in another investigational trial up to 12 months post-index procedure.

Treatment and study plan

EndoTex™ NexStent™

Device

EndoTex™ NexStent™ is a flexible, fine mesh Nitinol stent used to treat patients that are at high risk of adverse events from carotid endarterectomy and require carotid revascularization of a target vessel that has a reference diameter between 4mm and 9mm and stenosis that is less than 30mm in length.

Filter Wire EZ™

Device

EPI Fliter Wire EZ™ Embolic Protection System is indicated for use as a guide wire and embolic protection system to contain and remove embolic material (thrombus/debris) while performing angioplasty and stenting procedures in coronary saphenous vein bypass grafts and carotid arteries.

Primary outcomes

  1. Major clinical events at one-year defined as any death, stroke or myocardial infarction

    Time frame: 1 year

  2. 30-day event rate defined as any death, stroke or myocardial infarction less than or equal to 30-days post-procedure; plus the 31-day to 12-month event rate defined as any ipsilateral stroke including any death as a result of an ipsilateral stroke.

    Time frame: 1 year

Secondary outcomes

  1. NexStent™ technical success

    Time frame: post surgery

  2. FilterWire EZ™ technical success

    Time frame: post surgery

  3. Overall system technical success

    Time frame: post surgery

  4. Angiographic success

    Time frame: post procedure

  5. Procedure Success

    Time frame: 24 hours post procedure

  6. Restenosis

    Time frame: 1 year

  7. Target vessel revascularization

    Time frame: 1 year

Sponsors and collaborators

Lead sponsor

Boston Scientific Corporation

Industry

Registry information

Acronym: CABERNET

Important dates

Study start
2001
Primary completion
2005
Study completion
2007
First posted
Jan 24, 2008
Registry last updated
Jan 24, 2008

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.