CardioQ vs Thermodilution Measurements of Cardiac Output

Minimal invasive monitoring systems of central hemodynamics are gaining increasing popularity. The present study investigates the precision of the esophageal doppler (CardioQ) derived cardiac output and its agreement with pulmonary artery catheter thermodilution (PAC TD) for measuring CO during steady state and with induced hemodynamic changes in patients scheduled for elective cardiac surgery.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year–90 year

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Rigshospitalet, University of Copenhagen, Copenhagen, Capital Region, Denmark

Loading trial locations.

About this study

Twenty-five patients are planned to be enrolled. After induction of anesthesia, insertion of the PAC and the esophageal-doppler probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm, and CO are measured simultaneously using the CardioQ and PAC TD.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • patients scheduled for elective coronary artery bypass grafting (CABG), who are in stable sinus rhythm, who have a left ventricular ejection fraction > 0.40 measured by transthoracic echocardiography, and who have no significant valve pathology

Exclusion criteria

-

Treatment and study plan

induced changes in hemodynamics

Other

Twenty-five patients are planned enrolled. After induction of anesthesia, insertion of the PAC and the CardioQ probe, the patient are placed in the following successive positions: a) supine, b) head-down tilt, c) head-up tilt, d) supine, e) supine with phenylephrine administration f) pace heart rate 80 bpm, g) pace heart rate 110 bpm. CO are measured simultaneously using the TEE and thermodilution technique.

Primary outcomes

  1. Agreement of cardiac output determined with CardioQ, compared with thermodilution

    Time frame: Data are collected in the perioperative period (30min.)

    Data are collected for each patient in the perioperative period. Patients are followed in the first 24 hours. Data will after inclusion of the last data be analysed and appropiate statistics aplied.

Sponsors and collaborators

Lead sponsor

Hasse Moller-Sorensen

Other

Registry information

Official study title

Comparison of CardioQ and Pulmonary Artery Thermodilution Derived Cardiac Output Measurements

Important dates

Study start
2012
Primary completion
2013
Study completion
2013