Berthold Bein
Hamburg, Free and Hanseatic City of Hamburg, 20099, Germany
NCT Number: NCT02438228
The aim of the present study is to compare accuracy and precision of Cardiac Output (CO) by nine different pulse contour algorithms with transpulmonary thermodilution before and after cardiopulmonary bypass (CPB).
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Hamburg, Free and Hanseatic City of Hamburg, 20099, Germany
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
Time frame: After induction of anesthesia until the end of surgery
University Hospital Schleswig-Holstein
Other
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT03172689
Cardiac Output
Nijmegen, Gelderland, Netherlands
View Trial DetailsNCT04941248
Cardiac Output
Shanghai, Shanghai Municipality, China
View Trial DetailsNCT05648279
Anesthesia, Cardiac Output
Graz, Austria
View Trial DetailsNCT05428384
Cardiac Output, Cardiovascular Diseases
Augusta, Georgia, United States
View Trial Details