Maastricht University Medical Center
Maastricht, 6229 HX, Netherlands
NCT Number: NCT04475575
Corona Virus Disease (COVID-19), spread worldwide and has become an emergency of major international concern. In March 2020, the WHO declared the COVID-19 outbreak a global pandemic. Accurate and fast diagnosis is crucial in managing the pandemic. Current diagnostic approaches raise several difficulties: they are time-consuming, expensive, invasive, and most important lacking high sensitivity. The gold standard diagnostic test for COVID-19, reverse transcription polymerase chain reaction (RT-PCR), is highly dependent on adequate deep sampling of the swab in the naso- and oropharynx. A new diagnostic test that can correctly and rapidly identify infected patients and asymptomatic carriers is urgently required to prevent further virus transmission and thus reduce mortality rates.
Aim: This proof-of-principle study aims to investigate if an electronic nose (Aeonose) can distinguish individuals with antibodies from individuals without antibodies against COVID-19 based on analysis of volatile organic compounds (VOCs).
Methods: between April and July 2020, persons undergoing RT-PCR and a serology test for COVID-19 were recruited at Maastricht UMC+ for breath analysis. All participants had to breathe through the Aeonose for five consecutive minutes. The VOC pattern in their exhaled breath was then linked to the matching RT-PCR and serological test results.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Not applicable
Maastricht, 6229 HX, Netherlands
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
All participants breathed through the Aeonose for five minutes. This device contains metal-oxide sensors that change in conductivity upon reaction with VOCs in exhaled breath. These conductivity changes are input data for machine-learning and used for pattern recognition. A nose clip was placed on the nose of each participant to avoid entry of non-filtered air in the device. Before measuring, the Aeonose was flushed with room air, guided through a carbon filter as well. During each measurement, a video was displayed to distract the participant and to reduce the chance of hyperventilation. Failed breath tests were excluded from analysis; the reason for failure was documented. Four similar Aeonose devices were used for breath analysis. A full-measurement procedure required sixteen minutes.
Time frame: 3 months
Ability of the electronic nose (Aeonose) to distinguish individuals with antibodies from individuals without antibodies against COVID-19 based on analysis of volatile organic compounds (VOCs).
Maastricht University Medical Center
Other
Can the Electronic Nose Smell COVID-19 Antibodies? A Proof-of-principle Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT04475562
COVID-19, Coronaviridae Infections
Maastricht, Netherlands
View Trial DetailsNCT04510194
COVID-19, Coronaviridae Infections
Sylmar, California, United States
View Trial DetailsNCT04895475
COVID-19, Coronaviridae Infections
Cincinnati, Ohio, United States
View Trial DetailsNCT04885452
COVID-19, Coronaviridae Infections
Agen, France
View Trial Details