UF Health
Gainesville, Florida, 32610, United States
Location status: Recruiting
Location contact
Svetlana Chembrovich, MD
CONTACT
Yury Zasimovich, MD
CONTACT
NCT Number: NCT06512870
Near infrared spectroscopy (NIRS), a technique that relies on differential absorption of infrared light to provide relative estimation of tissue oxygenation, has been successfully used to monitor perfusion of various tissues, including muscle tissue of the lower extremity, however available research reports mixed success and this technology is not currently a standard of care for patients with leg fractures.
The investigators propose use of NIRS technology in patients with diagnosis of tibial fracture and acute compartment syndrome to detect / document impaired perfusion of the anterior compartment of the leg, as compared to their non-broken leg. The investigators also propose measurement of intramuscular glucose level in the affected leg and compare it to a fingerstick glucose to detect relative hypoglycemia in the affected muscular compartment. If proven effective, NIRS, or IM glucose, or both techniques could be used for clinical monitoring of patients with tibial fractures at risk for acute compartment syndrome.
Interested in participating?
Request Info18 year–75 year
All sexes
Observational
Gainesville, Florida, 32610, United States
Location status: Recruiting
Svetlana Chembrovich, MD
CONTACT
Yury Zasimovich, MD
CONTACT
Inclusion criteria
Procedure of enrollment:
When diagnosis of tibial fracture with vascular compromise or established ACS is made by the ED physician and confirmed by the Orthopedic surgeon, study team will be notified immediately (by the orthopedic service).
Study team member will approach the study candidate, explain the purpose of the study and obtain the informed consent.
After obtaining the consent, pre-scanning of the anterior compartment of the leg will be performed at bedside to measure the depth between the surface of the skin and the muscle.
If depth of the anterior muscular compartment found to be <2.5 cm, NIRS sensors will be applied to the skin of the broken leg at that location, and to the corresponding location on the uninjured leg. Sensors will be connected to the monitor and readings will be obtained until patient enters the OR.
Sensor will be removed from the skin of the injured extremity, but will stay in place on uninjured leg to describe tissue perfusion changed which occur during anesthesia.
When incision is made by the surgeon, upon entering the anterior muscular-fascial compartment, blood sample will be obtained from the cut surface of the muscle for glucose concentration measurement. At the same time fingerstick will be performed and capillary glucose will be measured. Both glucose readings will be recorded.
Before entering the anterior compartment, intracompartmental pressure measurement will be performed by the surgeon using a sterile arterial line catheter attached to the transducer connected to the anesthesia monitor, or with the Striker device - at surgeon discretion.
At completion of the surgery, sensor will be re-applied on the anterior compartment of the injured leg before dressing application.
Monitoring of both extremities will continue for 72 hrs following surgery, (if condition of the operative extremity permits presence of the sensor).
All available data stored in the monitor then will be downloaded and analyzed. (Please see more specific time points below).
Data analysis:
NIRS readings will be collected at the following time=points:
Means will be calculated for the injured and uninjured leg for all time points as mentioned above.
Graphs for means will be also created and analyzed. Additionally, the following data will be collected: demographic data ( patient's age, gender), fracture diagnosis, time from admission to surgery, type of surgery performed (external temporary fixation, internal fixation with intramedullary nail vs with plate(s)).
Data will be downloaded to the encrypted thumb-drive and transferred to a password-protected electronic file on HSC server. Only HRRC-approved investigators will have access to the files.
After completion of the study all electronic data will be destroyed. Temporary data sheets will be used to facilitate data collection. They will be stored in the locked cabinet in the Anesthesiology department offices, away from patient areas.
Upon enrollment patients will be given numbers from 1 to 10. After complete set of data is obtained, each patient will be de-identified. Should need arise to refer back to the electronic data, patients will be only identified by their numbers (from 1 to 10) and their respective sets of data.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
A technique that relies on differential absorption of infrared light to provide relative estimation of tissue oxygenation, has been successfully used to monitor perfusion of various tissues, including muscle tissue of the lower extremity.
Time frame: 72 hours
NIRS sensors will be applied to the skin overlying anterior compartment of the injuries and uninjured legs. Uninjured leg will serve as a control leg. Readings from both legs will be recorded continuously until patient enters OR for emergent surgery. At that point NIRS sensor will be removed to allow skin prep for surgical procedure. NIRS sensor will be re-applied to the skin at the completion of the surgery before leg is wrapped with the dressing. Monitoring of both extremities will be continued for 72 hours.
If NIRS readings of the affected extremity will be reliably lower as compared to unaffected extremity, and that difference will reverse after surgery (fasciotomy), where NIRS reading of the affected extremity should be at least equal to or, most likely, higher than those of the unaffected extremity, that will prove that NIRS monitoring can be used to detect acute compartment syndrome and muscular ischemia.
Time frame: once, intraoperatively
When incision is made by the surgeon, upon entering the anterior muscular-fascial compartment, surgeon will obtain small drop of blood (by aspiration with a 2 ml syringe from the cut surface of the muscle) and pass it on to the study personnel to apply it onto the test strip for glucose measurement. At the same time fingerstick will be performed and capillary glucose will be measured. Both glucose readings will be recorded.
If intramuscular glucose readings in the affected extremity show relative hypoglycemia, i.e. glucose in the affected compartment will be lower than the fingerstick performed at the hand at the same time, that will prove that intramuscular glucose monitoring can be used to detect acute compartment syndrome and muscular ischemia.
Contact information is provided by the study sponsor or research team.
Martin S Noguera, MS
CONTACT
Svetlana Chembrovich, MD
CONTACT
University of Florida
Other
Can Near Infrared Spectroscopy (NIRS) or Intramuscular Glucose Monitoring (IMGM) Detect Impaired Perfusion in the Anterior Compartment of the Leg in Patients With Tibial Fractures? "Proof of Concept" Pilot Study
Acronym: NIRS
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05672381
Cardiovascular Diseases, Compartment Syndrome of Forearm
Lebanon, New Hampshire, United States
View Trial DetailsNCT06764446
Amputation, Cardiovascular Diseases
Ankara, Turkey (Türkiye)
View Trial DetailsNCT06030635
Cardiovascular Diseases, Compartment Syndromes
Berlin, Germany
View Trial DetailsNCT03540394
Cardiovascular Diseases, Compartment Syndromes
London, Ontario, Canada
View Trial Details