Polyklinika Mytna
Bratislava, Slovakia
NCT Number: NCT02023398
Prospective, two-arm, randomized study of the effectiveness of the BTL-9000 HFT in achieving 3 cm or greater average waist circumferential reduction in HFT group of subjects relative to the base line and 1 cm or greater reduction relative to the average waist circumferential reduction of the Placebo group.
Looking for future studies?
Notify Me18 year–70 year
All sexes
Interventional
Not applicable
Bratislava, Slovakia
Prospective, randomized, blinded, two-arms study of waist circumferential reduction following 5 once-a-week treatments. One arm is the HFT group of 64 subjects who are treated with the BTL-9000 HFT and the other arm is the Placebo group of 38 subjects treated with the sham device. The objective of the study is to demonstrate the effectiveness of the BTL-9000 HFT treatment in achieving average post-treatment waist circumference reduction of 3 cm or greater across the waistline relative to the baseline assessment and of 1 cm or greater than the average waist circumferential reduction of the Placebo group.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Deep tissue heating with the BTL-9000 HFT for HFT group
Other names: BTL-9000 High Frequency Therapy
sham deep tissue heating with BTL-9000 HFT in Placebo group
Time frame: 1 month follow up after 5 once-a-week treatments
The subjects in the HFT group whose average post-treatment waist circumference shows reduction of 3 cm or greater across the waistline relative to the base line assessment and their mean waist circumferential reduction is 1 cm or greater than the average circumferential reduction of Placebo group are considered to meet the study primary outcome success criteria.
Time frame: 1 month follow up
Absence of adverse events (AE) associated with the treatment procedure. Safety evaluations of skin reaction in the treatment area would be conducted at every treatment and follow up visits
BTL Industries Ltd.
Industry
Evaluation of the Effectiveness of the BTL-9000 High Frequency Therapy for the Waist Circumferential Reduction
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02271672
Circumferential Reduction, Waist Circumferential Reduction
View Trial DetailsNCT02023385
Circumferential Reduction, Waist Circumferential Reduction
View Trial DetailsNCT04406935
Circumferential Reduction
Chestnut Hill, Massachusetts, United States
View Trial Details