Medical University of Warsaw
Warsaw, Poland
NCT Number: NCT01677546
Bolus calculator (BC) is one of the advanced functions in modern insulin pumps (CSII)models. Together with wireless communication with blood glucose meter potentially facilitates achieving the target post prandial glucose levels. In this RCT authors assessed whether use of wireless communication between compatible devices: MiniMed insulin pump and blood glucose meter Contour Link (CL), Bayer results in more frequently bolus calculator using and what is the impact of exerting this tool on metabolic control in type 1 diabetic patients.
Looking for future studies?
Notify Me7 year–18 year
All sexes
Interventional
Not applicable
Warsaw, Poland
In this RCT 156 patients were randomly assigned to one of the 3 arms: group A- subjects using insulin pump bolus calculator wirelessly connected with blood glucose meter, group B- subjects using insulin pump bolus calculator without wireless communication with blood glucose meter or group C- insulin pump, without bolus calculator function. We compared the glycated hemoglobin levels and post- prandial hypoglycaemia after 3 months of observation between the groups. We also assessed secondary endpoints (mentioned above).
Patients were estimated at three time points: at the beginning, after 6 weeks and after 3 months of intervention. Investigators performed computer reports at each visit, with Medtronic CareLink Pro software.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
Insulin pump bolus calculator wirelessly communicated with blood glucose meter (Contour Link)
Other names: Insulin pump, bolus calculator, bolus Wizard, Contour Link
Insulin pump bolus calculator without wireless communication with blood glucose meter (Contour Link)
Other names: Insulin pump, bolus calculator, bolus Wizard
Time frame: 3 months
Time frame: 2 hours after the meals
Post- prandial glycaemia is express as a mean post- prandial glycaemia counted after the meal consumed between 1- 6 pm during subsequently 7- 10 days
Time frame: 3 months
Simple questions regarded treatment satisfaction and wish to continuation.
Time frame: 3 months
Hypoglycaemia defined as glycaemia below 70 mg/dl and, separately, glycaemia below 50 mg/dl.
Time frame: 3 months
Number of self- blood glucose monitoring per day
Time frame: 3 months
Hyperglycaemia defined as glycaemia above 180 mg/dl
Time frame: 3 months
Number of meal boluses per day
Time frame: 3 months
Number of bolus calculator use per day
Time frame: 3 months
Total daily dose of insulin express as jm/kg/d
Time frame: 3 months
Body mass index- sds
Medical University of Warsaw
Other
The Impact of Insulin Pump Bolus Calculator and Wireless Communication With Blood Glucose Meter on Metabolic Control in Children With Type 1 Diabetes Mellitus - Randomised Control Trial
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07561086
Autoimmune Diseases, Diabetes Mellitus
Marsá Maţrūḩ, Mersa Matrouh, Egypt
View Trial DetailsNCT07177404
Autoimmune Diseases, Diabete Mellitus
Derby, United Kingdom
View Trial DetailsNCT03475108
Autoimmune Diseases, Behavior
Philadelphia, Pennsylvania, United States
View Trial DetailsNCT00639964
Autoimmune Diseases, Diabetes Mellitus
Lille, France
View Trial Details