Medical University of Vienna
Vienna, State of Vienna, 1090, Austria
NCT Number: NCT02296294
This volunteer study tests a recently developed whole-body bioimpedance spectroscopy device called Body Composition Monitor (BCM) which measures the body composition (i.e. the water content of the body).
Specifically, the investigators will evaluate the use of BCM for correct detection of intravenous administered crystalloids in the volunteers´ fluid compartments. Furthermore we will test the change over time of the volunteers´ volume status after an intravenous fluid therapy.
Looking for future studies?
Notify Me18 year–50 year
Male
Interventional
Not applicable
Vienna, State of Vienna, 1090, Austria
Technically assisted assessment of volume status may be useful to direct fluid administration.
As a prerequisite the investigators will test a recently developed whole-body bioimpedance spectroscopy device to determine fluid status in volunteers after an intravenous fluid therapy.
The correlation of infused fluid and change of the fluid status measured with Body Composition Monitor (BCM, Fresenius Medical Care, Germany) is still unknown.
Using a three-compartment physiologic tissue model, BCM determine total body fluid volume (TBV), extracellular volume (ECV), intracellular volume (ICV) and fluid overload (FO) as surplus or deficit of 'normal' extracellular volume. The BCM device measures resistance and reactance at 50 discrete frequencies covering the frequency spectrum from 5 to 1000 kHz through the entire patient via 4 electrodes placed on the wrist and ankle.
Fifteen volunteers will be enrolled in a randomized, blinded cross over study. After randomisation into one of two treatments the volunteer will receive either an iv isotonic fluid therapy of Elo-mel® (Fresenius Kabi Austria) at a rate of 0,50ml/kg/min for one hour or no fluid therapy. At the second study day the volunteer will obtain the opposite treatment.
We will perform BCM measurements every 10 minutes before, during and after the treatment for 6 hours or until the BCM results return to baseline. The results are stored on a BCM patient card automatically.
The main objective of this study is to detect the administered iv fluid in the extracellular compartment respectively in FO, TBV and ICV.
Secondary outcome parameters include the change over time of ICV, ECV, TBV and FO after the iv therapy at the study day "Fluid Therapy".
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
an iv isotonic crystalloid fluid therapy at a rate of 0,50ml/kg/min for one hour.
BCM measurements every 10 minutes for 6 hours.
Other names: BCM
Time frame: 6 hours
The primary outcome parameter is the correct detection of the iv fluid therapy by a corresponding increase in the parameters ExtraCellular Volume (ECV), Total Body Fluid Volume (TBV) and Fluid Overload (FO).
Time frame: 6 hours
Secondary outcome parameters include the change over time of ICV, ECV, TBV and FO after the iv therapy at the intervention "Fuid Therapy".
Medical University of Vienna
Other
Acronym: BCM_Volunteer
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT02765009
Body Weight, Critical Care
Belfort, France
View Trial DetailsNCT07593014
Body Fluid Compartments, Creatine Supplementation
View Trial Details