Faculty of Dentistry , Kafr El Shiekh University
Kafr ash Shaykh, Egypt
NCT Number: NCT04793503
The aim of this study was to compare the MBF and chewing efficiency of complete denture bases fabricated by conventional, 3D printing and milling techniques. The research hypothesis was that, there are no significant differences in MBF and chewing efficiency in complete dentures fabricated by the three methods.
Looking for future studies?
Notify Me50 year–65 year
All sexes
Interventional
Not applicable
Kafr ash Shaykh, Egypt
Participant selection and treatment This study will include a clinical experiment with a cross-over clinical trial design. For this study, 27completely edentulous participants with age range of 50-65 were selected from the outpatient clinic of the Removable Prosthodontic Department, Faculty of dentistry, Kafr Elsheikh University, Egypt. All participants had Angle class I jaw relation maxillomandibular relationship, normal alveolar ridge volume, no temporomandibular joint disorders, no heart disease, and no systemic diseases that affect the complete denture treatment procedures.
To reduce the effect of order of treatment on MBF, were successively given the following prosthesis i) complete dentures fabricated by the conventional technique ii) 3D printed complete dentures iii) milled complete dentures in a random order.
Construction of the CADCAM 3D printed denture The same steps of the conventional technique will be performed till the adjustment of occlusion rims then in the dental laboratory, the maxillary and mandibular definitive casts and the occlusal rims will be prepared for scanning with scan spray. Scanning will be performed with an optical 3D scanner . The files from the laser-scan will be translated into stereolithography (STL) files and the CDs are virtually designed in ExoCad software. After minor modifications in the positions of teeth were made, fabrication of the dentures will be approved and the digital denture base will be fabricated using 3D printing technique from Dental Pink resin
Construction of the CAD/CAM milled denture Once the complete denture has been virtually designed in CAD software (ExoCad software) a preview will be sent for evaluation using 3D viewing software. After minor modifications in the positions of teeth were made, fabrication of the dentures will be approved. The digital denture will be fabricated by the command software of the milling machine (ExoCad 5x milling machine) from prepolymerized resin acrylic pucks and the teeth (TSM Acetal Dental) were milled into template .After that the denture will be finished and polished according to the traditional procedures For all groups, after placement, clinical evaluations of the fit, retention, stability, occlusal relationship, esthetics, and phonetics were performed. Assessment of the occlusion was made with articulating paper, chairside adjustments were made and premature contacts were corrected. The patient was given a proper program for denture insertion and oral hygiene measures.
Assessment of biting force
After chewing, the samples will be then spat into transparent plastic bags, which The samples will be then scanned from both sides with a of resolution 500 dots per inch. The numbers of selected pixels will be recorded from the histogram for each side, and mean of those figures will be calculated. To assess the reproducibility of chewing, the subjects will be available to repeat the experiments on a different day.
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
the complete denture constructed by packing technique
The files from the laser-scan will be translated into stereolithography (STL) files and the CDs are virtually designed in ExoCad software
Once the complete denture has been virtually designed in CAD software (ExoCad software) a preview will be sent for evaluation using 3D viewing software
Time frame: Readings will be performed baseline 1 week after denture insertion then 1 month after denture insertion then 3 months after denture insertion.
Time frame: 3 months after denture insertion
Specimens will be prepared from two colored gums one with the flavor "Sour Berry" (white color) and the other with the flavor "Fancy Fruit" (orange color). Two strips of a standard size (30 9 18 9 3 mm) will be cut from each gum and manually stuck together.
Kafrelsheikh University
Other
Biting Force and Chewing Efficiency of Conventional and CAD/CAM Complete Dentures: A Cross-over Study
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT00114894
Bites and Stings, Chemically-Induced Disorders
Key West, Florida, United States
View Trial DetailsNCT06894420
Bites and Stings, Chemically-Induced Disorders
Başakşehir, Istanbul, Turkey (Türkiye)
View Trial DetailsNCT06211296
Aortic Stenosis, Aortic Valve Disease
Thousand Oaks, California, United States
View Trial DetailsNCT01604694
Abdominoplasty, Bites and Stings
Bordeaux, France
View Trial Details