NCT Number: NCT04062240
The researchers are trying to compare the results of two sensors when recorded simultaneously on opposite sides of the forehead.
Looking for future studies?
Notify Me18 year and older
All sexes
Observational
Rochester, Minnesota, 55905, United States
Bispectral Index (BIS) monitors are FDA approved to gauge depth of sedation by analyzing segments of electroencephalogram (EEG) waves. The BIS monitor utilizes a proprietary algorithm to process the EEG information second by second, and outputs a number (0-100) that corresponds with a patient's level of consciousness. A level of 0 indicates no EEG activity; a level of 100 indicates awake EEG activity. Several studies demonstrated that BIS monitors may not be useful in paralyzed patients, as patients who were paralyzed and not sedated unexpectedly showed a large decrease in their BIS values following administration paralytic medications. Vivien et al found BIS values dropped an average of 24 points in already sedated patients when the patients were given paralytics. In the same year, Messner and colleagues paralyzed non-sedated volunteers and found a dramatic drop in BIS values until paralysis wore off or was reversed. Schuller et al repeated the Messner experiment and found similar results with 18 of 20 non-sedated volunteer's BIS values dropping to levels expected of patients who were sedated. These results suggest that BIS monitors are integrating electromyography (EMG) data into its algorithm to derive a BIS value. Our hypothesis is that a BIS monitor commenced after paralysis, thereby lacking exposure to any "awake" EMG activity, will result in a cleaner data set and more accurate representation of a patient's level of sedation. Studying in this manner will require the subject to wear two BIS sensors in a frontal montage. The manufacturer of the sensors gives no guidance as to which side of the forehead an individual sensor is placed, and no studies demonstrate BIS validity with the use of concurrent sensors. The purpose of the present investigation is to assess the measurement difference and variability associated with use of concurrent bifrontal BIS sensors. The data obtained will be used as a framework for a future study related to the use of paralytics and BIS monitoring.
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
Exclusion criteria
BIS sensors will be labeled L and R. The degree of variability between the concurrent use of the sensors will be assessed .
Time frame: 10 minutes where both sensors are recording concurrently
Degree of variability between the values produced by the BIS sensors in a bifrontal montage when monitored simultaneously by use of a Bland-Altmann plot. The average value of each timed pair was plotted against the difference between the pairs.
The BIS monitor outputs data on a scale of 0-100 in arbitrary units; 0 = an isoelectric state on EEG, 100 = fully awake patient. BIS values of 40-60 are thought to reduce the chance of patient recall during general anesthesia.
For the purpose of this study, a smaller confidence interval is better as it indicates a higher level of agreement between the two BIS sensors.
Time frame: 10 minutes where both sensors are recording concurrently
Degree to which Ketamine may influence BIS values
Mayo Clinic
Other
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05320718
Anesthesia, Local, Regional Anesthesia
Beijing, Beijing Municipality, China
View Trial DetailsNCT05552092
Surgery
Gwangju, South Korea
View Trial DetailsNCT03369210
Anemia, Hematologic Diseases
Aachen, Germany
View Trial DetailsNCT04846855
Anesthesia, Local, Hematologic Diseases
Quincy-sous-Sénart, IDF, France
View Trial Details