NCT Number: NCT07066774

Biopsy Needle Size in Soft Tissue Sarcoma

Soft tissue sarcomas (STS) require accurate biopsy for diagnosis, grading, and management decisions. Although tru-cut biopsy is widely used, the optimal needle gauge remains uncertain. This study aimed to compare diagnostic accuracy and biopsy concordance rates of 14 G, 16 G, and 18 G tru-cut biopsy needles for extremity STS.

1. Is there any difference between the diagnostic accuracy measurements of 14G, 16G and 18G tru-cut biopsy needles for diagnosis of soft tissue sarcomas in extremities? 2. Do tumor size, tumor depth, tumor subtype and histological grade of the tumor affect the "matching score"s of biopsies? 3. Do tumor size, tumor depth, tumor subtype and histological grade of the tumor affect the biopsy result concordance and/or diagnostic accuracy measurements? 4. Does needle gauge effect successful tumoral tissue sampling or prediction of histological grade of soft tissue sarcomas?

Completed

Looking for future studies?

Notify Me

Key information

Sex eligibility

All sexes

Study type

Interventional

Phase

Not applicable

Primary location

Ankara Bilkent City Hospital

Ankara, Cankaya, 06800, Turkey (Türkiye)

About this study

In 2018, the National Comprehensive Cancer Network (NCCN) endorsed core-needle (tru-cut) biopsy as the preferred diagnostic modality for STSs [14]. They recommend obtaining at least three tissue core blocks through a single stab incision on the skin, with a 14-gauge needle, directing the needle along different trajectories. In clinical practice, both 14 G and 16 G cores are commonly used Although multiple tru-cut needle gauges are used in practice, to our knowledge, an ideal and safe biopsy needle that does not sacrife diagnostic performance has not been defined. This is a randomized prospective disagnostic accuracy study. Therefore we prospectively compared numerous variables (tumor size, tumor depth, subtype, histological grade etc.) with biopsy result concordance and diagnostic accuracy of 14 G, 16 G, and 18 G tru-cut needles in samples obtained from the same tumor for each patient with suspected extremity STS, to determine whether an optimal needle gauge exists.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Patients presenting to the Orthopedic Oncology outpatient clinic at Ankara Bilkent City Hospital with suspected or preliminary findings on physical examination suggesting soft tissue sarcoma.

Patients presenting to the Orthopedic Oncology outpatient clinic at Ankara Bilkent City Hospital with suspected or preliminary findings on radiological imaging suggesting soft tissue sarcoma.

Patients with soft tissue masses in extremities which require pathological examination

Exclusion criteria

  • Patients with a prior diagnosis of the existing mass, coagulation disorders, active infection at the tumor site, a history of previous surgery or radiotherapy to the tumor region, medical conditions contraindicating tru-cut biopsy, or those who did not consent to participate after detailed explanation of the study, were excluded.

Treatment and study plan

Tru-cut Biopsy with 14 G Needle

Diagnostic Test

Each participant underwent Percutaneous Tru-cut Biopsy with 14G tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

Tru-cut Biopsy with 16G tru-cut needle

Diagnostic Test

Each participant underwent Percutaneous Tru-cut Biopsy with 16 tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

Tru-cut Biopsy with 18G tru-cut needle

Diagnostic Test

Each participant underwent Percutaneous Tru-cut Biopsy with 18G tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

Primary outcomes

  1. Diagnostic accuracy methods

    Time frame: From enrollment to the end of study at 4 months

    Sensitivity, specificity, positive predictive value, negative predictive value, false positive rate and false negative rate was analyzed for 3 different needle sizes

Sponsors and collaborators

Lead sponsor

Ankara City Hospital Bilkent

Other

Collaborators

  • Geotek Medical Products Industry and Trade Co., Ltd., Ankara, Türkiye

Registry information

Official study title

Diagnostic Accuracy of Different Tru-Cut Needle Sizes in Soft Tissue Sarcomas: A Prospective Blinded Study

Important dates

Study start
2025
Primary completion
2025
Study completion
2025
First posted
Jul 15, 2025
Registry last updated
Jul 15, 2025

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.