sacroiliac belt
Devicestanding and walking with the belt on and with the belt off
Other names: pelvic belt
NCT Number: NCT03334799
Women with pelvic girdle pain PGP) often get relief from using a sacroiliac belt. The study will explore if there are differences and in the changes of lower body movement in stability with the belt on and with the belt off. Women with PGP will be matched with women without to explore if there is a difference between these two groups. This will be looked at in standing and in walking.
Looking for future studies?
Notify Me18 year–50 year
Female
Interventional
Not applicable
SacroIliac (SI) joint dysfunction (also called pelvic girdle pain) has been associated with impaired load transfer across the lumbopelvic region. This can result in lower back pain as well as poor biomechanical adaptation during walking. Sacroiliac (SI) belts have typically been prescribed in order to mitigate pain and improve load transfer in individuals with SI joint dysfunction. It has been speculated that SI belts have the ability to instantaneously increase joint stability, and as a result improve load transfer and muscle activation and recruitment. However, this speculation is primarily based on anecdotal evidence; there is little biomechanical research supporting the effects of wearing an SI belt. In order to gain an improved understanding of the biomechanical effects of wearing an SI belt, the investigators propose to conduct a study with the following key objectives:
Variables measured will include:
Healthy volunteers accepted: Yes
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
and matched controls by age (within 5 years), BMI (within one point) and parity
Exclusion criteria
standing and walking with the belt on and with the belt off
Other names: pelvic belt
Time frame: within 2 months of enrollment, measured at one point in time
Pressure insoles will be used to quantify the 95% confidence ellipse area of the CoP determined from each of the 2 feet, during the 30 second standing trials. The sampling will be compounded at a rate of 100 Hz and provided a time-pressure series with a range from 15 to 1200 kPa. The 95% confidence ellipse area of both feet will be summed. The average of the 3 trials will be used. Kinematic data will be collected using eight high speed video cameras at a sample rate of 240 Hz. All test subjects will be equipped with a marker set consisting of 32 light reflecting markers according to Visual3D (C-Motion, Inc., Germantown, USA) marker set guidelines. All measurements will be made on the right side. Walking speed will be monitored using photo electronic cells. Identified and averaged for 10 over-ground walking trials for each participant using custom Matlab software (MathWorks Inc., Natick, MA, USA).
Time frame: within 2 months of enrollment, measured at one point in time
Pressure insoles (Pedar, novel GmbH, Germany) will be used to quantify the 95% confidence ellipse area of the CoP determined from each of the 2 feet, during the 30 second standing trials. The sampling will be compounded at a rate of 100 Hz and provided a time-pressure series with a range from 15 to 1200 kPa. Prior to testing, the insoles will be calibrated as per the manufacture's protocol. All data will be analyzed using custom Matlab scripts. The 95% confidence ellipse area of both feet will be summed. The average of the 3 trials will be used.Gait variability will be assessed by calculating the average position of the CoP in the medial-lateral direction during walking using pedar pressure insoles. The mean and standard deviation of the average CoP position will be defined as gait variability in medial-lateral direction calculated for each subject, foot, and condition.
Time frame: within 2 months of enrollment, measured at one point in time
A force plate (Kistler Instrumente AG, Switzerland) recording at 2400 Hz will be positioned in the middle of a 15 meter walkway to measure ground reaction forces (GRF) during standing and walking. The threshold for determining heel strike wil be 20 N. Walking speed will be monitored using photo electronic cells (model TC Timing System; Brower Timing Systems, Draper, UT). Discrete kinematic and kinetic variables will be identified and averaged for 10 over-ground walking trials for each participant using custom Matlab software (MathWorks Inc., Natick, MA, USA).
Kinematic data will be collected using eight high speed video cameras (Motion Analysis Corporation, Santa Rosa, USA) Version 3.6.1.1315 at a sample rate of 240 Hz. All test subjects will be equipped with a marker set consisting of 32 light reflecting markers according to Visual3D (C-Motion, Inc., Germantown, USA) marker set guidelines. All measurements will be made on the right side.
University of Calgary
Other
A Case-Control Pilot Study on the Biomechanical Effects of Wearing a Sacroiliac Belt in Women
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT05403424
Musculoskeletal Pain, Neurologic Manifestations
Istanbul, Turkey (Türkiye)
View Trial DetailsNCT07292701
Female Urogenital Diseases and Pregnancy Complications, Kinesiotaping
Cairo, Egypt
View Trial DetailsNCT06705933
Musculoskeletal Pain, Neurologic Manifestations
Cairo, Egypt
View Trial DetailsNCT05403437
Diabetes Mellitus, Diabetes, Gestational
Istanbul, Turkey (Türkiye)
View Trial Details