Skip to main content
OpenTrials
Completed

NCT Number: NCT02764073

Bioimpedance Spectroscopy for the Evaluation of Heart Failure

Despite impressive improvements in treatment strategies, heart failure (HF) morbidity and mortality remains substantially high worldwide. Pulmonary congestion is considered the leading cause for hospital admissions and death among patients with HF. Physical examination is crucial for titrating medical treatment in these patients, but despite a good specificity it is not sensitive enough to detect early elevated cardiac filling pressures.

The N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a recognized powerful predictor for HF prognosis. Recently, cardiotrophin-1 and galectin-3 have been proposed as new relevant biomarkers for HF evaluation.

Echocardiography can be also used to noninvasively measure left ventricular filling pressures. Lung ultrasound (LUS) through interstitial B-line evaluation has been recently proposed as a bed-side, noninvasive tool to assess interstitial lung water. B-lines correlate with NT-proBNP and E/e' levels in patients with acute dyspnea, chronic HF or after a stress test. LUS can also identify clinically silent pulmonary edema, suggesting that it may complement clinical evaluation to improve hemodynamic profiling and treatment optimization.

Biompedance is a bedside method for total body fluid status assessment. It defines individual fluid status/compartments/overload on the basis of an individual's normal extracellular volume and body composition. Recent studies indicate that bioimpedance-derived fluid overload indices are independent predictors of mortality in renal failure patients.

To date, no study has evaluated bioimpedance performance for fluid assessment in HF patients. The investigators aim to cross-sectionally compare bioimpedance parameters with clinical evaluation, LUS, cardiac biomarkers, and echocardiographic characteristics, in a cohort of incident consecutive patients with HF. Two years patients' survival will be evaluated to propose the best evaluative algorithm and rank the various methods for prognostic significance.

Completed

Looking for future studies?

Notify Me

Key information

Age range

18 year and older

Sex eligibility

All sexes

Study type

Observational

Primary location

Dr. CI Parhon

Iași, Romania

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • age ≥18 years;
  • HF diagnosis regardless of cause as defined by the Framingham criteria and satisfying the European Society of Cardiology guidelines;

Exclusion criteria

  • metallic joint prostheses, cardiac stent or pacemakers, decompensated cirrhosis, pregnancy and limb amputations (due to bioimpedance technique limitations);
  • no prior diagnosis of pulmonary fibrosis (due to lung ultrasonography limitations);
  • absence of congenital heart disease

Treatment and study plan

Bioimpedance Spectroscopy

Device

The technique involves attaching electrodes to the patient's forearm and ipsilateral ankle, with the patient in a supine position. The BCM® measures the body resistance and reactance to electrical currents of 50 discrete frequencies, ranging between 5 and 1000 kHz. Based on a fluid model using these resistances, the extracellular water (ECW), the intracellular water (ICW) and the total body water (TBW) are calculated. All calculations are automatically performed by the software of the BCM® device. Absolute fluid overload (AFO) is is defined as the difference between the expected patient's ECW under normal physiological conditions and the actual ECW, whereas the relative fluid overload (RFO) is defined as the absolute fluid overload AFO to ECW ratio.

Other names: BCM®Body Composition Monitor - Fresenius Medical Care D GmbH

lung ultrasonography

Device

Examinations will be performed in the supine position. Scanning of the anterior and lateral chest will be performed on both sides of the chest, from the second to the fourth (on the right side to the fifth) intercostal spaces, at parasternal to mid-axillary lines. B-lines will be recorded in each intercostal space and were defined as a hyperechoic, coherent US bundle at narrow basis going from the transducer to the limit of the screen. B-lines starting from the pleural line can be either localized or scattered to the whole lung and be present as isolated or multiple artifacts (with a distance 7 mm between 2 artifacts). The sum of B-lines produces a score reflecting the extent of lung water accumulation (0 being no detectable B-line).

Echocardiography

Device

All echocardiographic measurements will be carried out according to the recommendations of the American Society of Echocardiography by an observer unaware of the lung ultrasound and bioimpedance results. Echocardiographic evaluation will provide information about cardiac anatomy (e.g. volumes, geometry, mass) and function (e.g. left ventricular function and wall motion, valvular function, right ventricular function, pulmonary artery pressure, pericardium).

Primary outcomes

  1. The relationship between bioimpedance derived parameters (TBW, ICW, ECW, RFO), clinical assessment, lung congestion (as assessed by lung ultrasonography), echocardiography and different cardiac biomarkers.

    Time frame: 2 years

Secondary outcomes

  1. The impact of baseline bioimpedance characteristics (TBW, ICW, ECW, RFO) on all-cause mortality.

    Time frame: 2 years

  2. The impact of baseline bioimpedance characteristics (TBW, ICW, ECW, RFO) on fatal and non-fatal cardiovascular events.

    Time frame: 2 years

  3. The impact of baseline bioimpedance characteristics (TBW, ICW, ECW, RFO) on hospitalizations.

    Time frame: 2 years

Sponsors and collaborators

Lead sponsor

Grigore T. Popa University of Medicine and Pharmacy

Other

Registry information

Official study title

Bioimpedance Spectroscopy for the Evaluation of Heart Failure - a Comparison With Clinical Assessment, Lung Ultrasonography, Cardiac Biomarkers and Echocardiography

Acronym: BIS-HF

Important dates

Study start
2016
Primary completion
2020
Study completion
2020
First posted
May 6, 2016
Registry last updated
Jan 26, 2021

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.