PRO-Kinetic Energy Stent
DeviceCoronary artery stent implant
NCT Number: NCT01612767
The purpose of this study is to demonstrate the safety and efficacy of the investigational BIOTRONIK PRO-Kinetic Energy stent in subjects with atherosclerotic disease of native coronary arteries.
Looking for future studies?
Notify Me18 year and older
All sexes
Interventional
Phase 2 / Phase 3
Medellín, Colombia
Healthy volunteers accepted: No
Only the study team can determine whether someone qualifies for participation.
Inclusion criteria
For a subject to be enrolled in the study and considered for the index procedure, the following initial inclusion criteria must be met:
For a subject to receive an investigational stent, the following procedure-related criteria must be met:
Exclusion criteria
For a subject to be enrolled in the study and considered for the index procedure, the following initial exclusion criteria must not be present:
For a subject to receive an investigational stent the following procedure-related criteria must not be present:
> 1 mm ST segment elevation or depression in consecutive leads New left bundle branch block (LBBB) Development of pathological Q-waves in two contiguous leads of the electrocardiogram (ECG)
Coronary artery stent implant
Time frame: 9 months post-index procedure
The primary endpoint for the Pro-Kinetic Energy Stent is the target vessel failure rate at 9-months post-index procedure. Target vessel failure is defined as cardiac death, myocardial infarction and ischemia-driven target vessel revascularization.
Time frame: 1, 12, 24 and 36 months post-index procedure
Evaluate the target vessel failure rate at 1, 12, 24, and 36 months post-index procedure. Target vessel failure is defined as cardiac death, myocardial infarction (MI) and ischemia-driven target vessel revascularization.
Time frame: 1, 12, 24 and 36 months post-index procedure
Contribution of each event type (cardiac death, myocardial infarction (MI) and ischemia-driven target vessel revascularization) to composite rate of target vessel failure.
Time frame: 1, 9, 12, 24 and 36 months post-index procedure
Evaluate the overall target vessel revascularization rate of the PRO-Kinetic Energy stent. The rate includes both ischemia-driven revascularization procedures of the target vessel, as well as revascularization procedures of the target vessel without prior clinical symptoms.
Time frame: 1, 9, 12, 24 and 36 months post-index procedure
Evaluate the target lesion failure rate of the PRO-Kinetic Energy stent. Target lesion failure includes cardiac death, MI, and ischemia-driven target lesion revascularization.
Time frame: 1, 9, 12, 24, and 36 months post-index procedure
The contribution of each individual event of cardiac death, myocardial infarction, and ischemia-driven target lesion revascularization to the overall rate of target lesion failure.
Time frame: 1, 9, 12, 24 and 36 months post-index procedure
Evaluate the overall target lesion revascularization rate associated with the PRO-Kinetic Energy stent. The overall target lesion revascularization rate includes both ischemia-driven revascularization procedures of the target lesion, as well as revascularization procedures of the target lesion without prior clinical symptoms.
Time frame: 1, 9, 12, 24, and 36 months post-index procedure
Characterize the overall safety of the PRO-Kinetic Energy stent by evaluating the composite rate of all-cause mortality and all-cause myocardial infarction.
Time frame: 1, 9, 12, 24, and 36 months post-index procedure
Contribution of the individual rates of mortality and myocardial infarction to the overall composite safety rate.
Time frame: 1, 9, 12, 24 and 36 months post-index procedure
Evaluate the stent thrombosis rate associated with the PRO-Kinetic Energy stent. Stent thrombosis was classified according to both timing and evidence as outlined by the ARC definition of stent thrombosis. Participants were included in the evaluations at visit intervals if they had a visit at the specified interval or a thrombosis was reported at or before the visit.
Time frame: Index procedure
Evaluate the index procedure success associated with the implant of the PR-Kinetic Energy stent. procedure success is defined as the successful delivery and deployment of the investiational stent at the intended target lesion in combination with any adjunctive device (if applicable) to attain a final residual stenosis of < 30% by operator visual estimate without the occurrence of cardiac death, any MI (target vessel or non-target vessel) or TLR prior to hospital discharge.
Time frame: Index procedure
Evaluate the device success associated with the implant of the PRO-Kinetic Energy stent. Device success is defined as the successful delivery and deployment of the investigational stent at the intended target lesion in combination with standard post-dilation (if applicable) to attain a final residual stenosis of < 30% by operator visual estimate.
Time frame: Index procedure
Evaluate the lesion success associated with the implant of the PRO-Kinetic Energy stent. Lesion success is defined as the successful delivery and deployment of the investigational stent at the intended target lesion in combination with any adjunctive device (if applicable) to attain a final residual stenosis of < 30% by operator visual estimate.
Time frame: Basline, Discharge, 1, 9, 12, 24 and 36 months post-index procedure
Evaluate the angina pectoris classification at each study visit.
Stable angina pectoris was classified according to the Canadian Cardiovascular Society's System: Stable Angina - Class I: normal activity does not cause angina; Stable Angina - Class II: slight limitation of normal activity, moderate exertion may cause angina; Stable Angina - Class III: marked limitation of ordinary physical activity; Stable Angina - Class IV: discomfort with any physical activity and pain may be present at rest
Unstable angina pectoris was classified according to the Braunwald System: Numeral I: newly onset severe or accelerated angina with no pain at rest; Numeral II: angina at rest within the preceding month but not the past 48 hours Numeral III: angina at rest within the preceding 48 hours; Letter A: develops in presence of conditions which intensify ischemia; Letter B: develops in the absence of extracardiac conditions; Letter C: develops within 2 weeks after an acute myocardial infarction
Biotronik, Inc.
Industry
The Treatment of Coronary Artery Lesions Using the PRO-Kinetic Energy Cobalt-Chromium, Bare-Metal Stent
Acronym: BIOHELIX-I
OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.
View the official ClinicalTrials.gov record (opens in a new tab)This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.
Published trials that share one or more normalized conditions with this study.
NCT07592312
Acute Coronary Syndrome, Acute Coronary Syndromes (ACS)
View Trial Details