Skip to main content
OpenTrials
Completed

NCT Number: NCT02028728

BIOFLOW III Satellite-Italy Orsiro Stent System

Clinical evaluation of the Orsiro LESS in subjects requiring coronary revascularization with Drug Eluting Stents (DES). 500 subjects will be enrolled in this registry. The sample size maybe increased in order to reach the subgroup sizes (Diabetes, small vessel, AMI and CTO).

Completed

Looking for future studies?

Notify Me

Key information

About this study

For the majority of Coronary Artery Disease (CAD) treatment with Percutaneous Transluminal Coronary Angioplasty (PTCA) provides high initial procedure success. However, the medium to long-term complications range from rather immediate elastic coil or vessel contraction to longer processes like smooth muscle cell proliferation and excessive production of extra cellular matrix, thrombus formation and atherosclerotic changes like restenosis or angiographic re-narrowing. The reported incidence of restenosis after PTCA ranges from 30 to 50%. Such rates of recurrence have serious economic consequences. Bare Metal Stents (BMS), designed to address the limitations of PTCA, reduced the angiographic and clinical restenosis rates in De Novo lesions compared to PTCA alone and decreased the need for CABG. BMS substantially reduced the incidence of abrupt artery closure, but restenosis still occurred in about 20 to 40% of cases, necessitating repeat procedures.

The invention of Drug Eluting Stents (DES) significantly improved on the principle of BMS by adding an antiproliferative drug (directly immobilized on the stent surface or released from a polymer matrix), which inhibits neontimal hyperplasia. The introduction of DES greatly reduced the incidence of restenosis and resulted in better safety profile as compared to BMS with systemic drug administration. These advantages and a lower cost compared to surgical interventions has made DES an attractive option to treat coronary artery disease.

Therefore this observational registry has been designed for the clinical evaluation of the ORSIRO LESS requiring coronary revascularization with DES. Results will contribute to the collection of clinical evidence for the clinical Performance.

Who can participate

Healthy volunteers accepted: No

Only the study team can determine whether someone qualifies for participation.

Inclusion criteria

  • Symptomatic coronary artery disease
  • Subject signed informed consent for data release
  • Subject is geographically stable and willing to participate at all follow up assessments
  • Subject is ≥ 18 years of age

Exclusion criteria

  • Subject did not sign informed consent
  • Pregnancy
  • Known intolerance to aspirin, clopidogrel, Ticlopidine, heparin or any other anticoagulant/antiplatelet therapy required for PCI, stainless steel, Sirolimus or contrast media
  • Planned surgery within 6 months after PCI unless dual antiplatelet therapy will be maintained
  • Currently participating in another study and primary endpoint not reached yet

Treatment and study plan

Primary outcomes

  1. Target Lesion Failure (TLF)

    Time frame: 12 months

    Composite of cardiac death, target vessel Q-wave or non Q-wave Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG) and clinically driven Target Lesion Revascularization (TLR).

Secondary outcomes

  1. TLF

    Time frame: 6 and 18 months

    Composite of cardiac death, target vessel Q-wave or non Q-wave Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG) and clinically driven Target Lesion Revascularization (TLR).

  2. Target Vessel Revascularization (TVR)

    Time frame: 6, 12 and 18 months

    Any repeat revascularization of the target vessel.

  3. Target Lesion Revascularization (TLR)

    Time frame: 6, 12 and 18 months

    Defined as any repeat revascularization of the target lesion

  4. Stent Thrombosis

    Time frame: 6, 12 and 18 months

    Definite, Probable and Possible Stent Thrombosis

  5. Clinical device success

    Time frame: Up to discharge

    Successful delivery and deployment of the investigational stent (s) at the intended target lesion and successful withdrawal of the stent delivery system with attainment of a final residual stenosis of less than 50% by visual estimation and without use of a device outside the assigned treatment strategy.

  6. Clinical procedural success

    Time frame: up to seven days

    Successful delivery and deployment of the investigational stent (s) at the intended target lesion and successful withdrawal of the stent delivery system with attainment of a final residual stenosis of less than 50% by visual estimation and without using any adjunctive device without the occurrence of ischemia-driven major adverse cardiac event during the hospital stay to a maximum of the first seven days post index procedure.

Sponsors and collaborators

Lead sponsor

Biotronik Italia S.p.A.

Industry

Registry information

Official study title

Safety and Performance Registry for an All Comers Patient Population With the Limus Eluting Orsiro Stent Within Daily Clinical Practice III-Italy

Important dates

Study start
2014
Primary completion
2016
Study completion
2016
First posted
Jan 7, 2014
Registry last updated
Oct 2, 2017

OpenTrials presents study information sourced from ClinicalTrials.gov. The official registry record should be consulted for the latest information.

View the official ClinicalTrials.gov record (opens in a new tab)

This listing is for discovery and informational purposes only. It is not medical advice, does not guarantee that a study is recruiting, and does not determine eligibility. Contact the study team and a qualified healthcare professional when considering participation.

Published trials that share one or more normalized conditions with this study.