Pharmacokinetic parameter of total iron in serum: AUC0-∞
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
AUC0-∞ is the area under the curve from dosing to extrapolated infinite time. AUC0-∞ = AUC0-t + Ct / λz, where Ct is the last measurable concentration, and λz is the elimination rate constant.
-
Pharmacokinetic parameter of total iron in serum: Tmax
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
Tmax is the time to reach maximum concentration of total serum iron.
-
Pharmacokinetic parameter of total iron in serum: t1/2
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
t1/2 is the terminal elimination half-life of total serum iron. It is calculated as ln2 / λz.
-
Pharmacokinetic parameter of total iron in serum:λz
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
λz is the elimination rate constant of total serum iron. It is calculated as the negative reciprocal of the slope of the terminal phase of the logarithm-linear drug concentration-time curve using linear regression.
-
Pharmacokinetic parameter of transferrin bound iron in serum: AUC0-∞
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
AUC0-∞ is the area under the curve from dosing to extrapolated infinite time. AUC0-∞ = AUC0-t + Ct / λz, where Ct is the last measurable concentration, and λz is the elimination rate constant.
-
Pharmacokinetic parameter of transferrin bound iron in serum: Tmax
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
Tmax is the time to reach maximum concentration of serum transferrin bound iron.
-
Pharmacokinetic parameter of transferrin bound iron in serum: t1/2
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
t1/2 is the terminal elimination half-life of transferrin bound iron. It is calculated as ln2 / λz.
-
Pharmacokinetic parameter of transferrin bound iron in serum:λz
Time frame: 24hours,12hours,0hour before administration, and 5minutes,10minutes,15minutes,30minutes,45minutes,1hour,1.5hours,2hours,4hours,6hours,8hours,10hours,12hours,24hours,36hours,48hours,72hours,96hours,120hours and 144hours after administration.
λz is the elimination rate constant of transferrin bound iron. It is calculated as the negative reciprocal of the slope of the terminal phase of the logarithm-linear drug concentration-time curve using linear regression.